Thermodilution And Indirect Fick Are Inaccurate Methodologies To Determine Cardiac Index In Patients With Pulmonary Arterial Hypertension

被引:0
|
作者
Ahmed, M. K. [1 ]
Dweik, R. [2 ]
Agmy, G. [1 ]
Tonelli, A. R. [2 ]
机构
[1] Assiut Univ, Assiut, Egypt
[2] Cleveland Clin, Cleveland, OH 44106 USA
关键词
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
A7327
引用
收藏
页数:1
相关论文
共 50 条
  • [21] Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device: Discordance Between Thermodilution and Indirect Fick Cardiac Output Measurements
    Tehrani, David M.
    Grinstein, Jonathan
    Kalantari, Sara
    Kim, Gene
    Sarswat, Nitasha
    Adatya, Sirtaz
    Sayer, Gabriel
    Uriel, Nir
    ASAIO JOURNAL, 2017, 63 (04) : 433 - 437
  • [22] Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    Sakka, SG
    Reinhart, K
    Meier-Hellmann, A
    INTENSIVE CARE MEDICINE, 1999, 25 (08) : 843 - 846
  • [23] COMPARISON OF DIRECT FICK AND THERMODILUTION MEASUREMENTS OF CARDIAC-OUTPUT IN PRIMARY PULMONARY-HYPERTENSION AND CHRONIC OBSTRUCTIVE AIRWAYS DISEASE
    FITZPATRICK, M
    JONES, K
    HIGENBOTTAM, T
    SHAW, D
    WALLWORK, J
    CLINICAL SCIENCE, 1985, 69 : P55 - P55
  • [24] Cardiac sympathetic activation in patients with pulmonary arterial hypertension
    Mak, Susanna
    Witte, Klaus K.
    Al-Hesayen, Abdul
    Granton, John J.
    Parker, John D.
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2012, 302 (10) : R1153 - R1157
  • [25] Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients
    Axler, O
    Tousignant, C
    Thompson, CR
    DallavaSantucci, J
    Phang, PT
    Russell, JA
    Walley, KR
    JOURNAL OF CRITICAL CARE, 1996, 11 (03) : 109 - 116
  • [26] Comparison of Different Methods to Estimate Cardiac Index in Pulmonary Arterial Hypertension
    Khirfan, Ghaleb
    Ahmed, Mostafa K.
    Almaaitah, Saja
    Almoushref, Alla
    Agmy, Gamal M.
    Dweik, Raed A.
    Tonelli, Adriano R.
    CIRCULATION, 2019, 140 (08) : 705 - 707
  • [27] Thermodilution vs indirect fick cardiac output measurement in clinical practice: insights from a tertiary centre
    Pereira, A.
    Santos, J. G.
    Loureiro, M. J.
    Ferreira, F.
    Almeida, A. R.
    Cale, R.
    Repolho, D.
    Vitorino, S.
    Morgado, J.
    Pereira, H.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2252 - 2252
  • [28] Lack of agreement between thermodilution and fick cardiac output in critically ill patients
    Dhingra, VK
    Fenwick, JC
    Walley, KR
    Chittock, DR
    Ronco, JJ
    CHEST, 2002, 122 (03) : 990 - 997
  • [29] Cardiac dysfunction of pulmonary artery aneurysm in patients with pulmonary arterial hypertension
    Sakata, Konomi
    Satoh, Toru
    Isaka, Aoi
    Uesugi, Yoichiro
    Furuya, Mitsufumi
    Matsushita, Kenichi
    Yoshino, Hideaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 228 : 1035 - 1040
  • [30] Arterial thermodilution:: an alternative to pulmonary artery catheter for cardiac output assessment in burn patients
    Holm, C
    Melcer, B
    Hörbrand, F
    von Donnersmarck, GH
    Mühlbauer, W
    BURNS, 2001, 27 (02) : 161 - 166