Practical methods for improving dose distributions in Monte Carlo-based IMRT planning of lung wall-seated tumors treated with SBRT

被引:14
|
作者
Altman, Michael B. [1 ]
Jin, Jian-Yue [1 ]
Kim, Sangroh [1 ]
Wen, Ning [1 ]
Liu, Dezhi [1 ]
Siddiqui, M. Salim [1 ]
Ajlouni, Munther I. [1 ]
Movsas, Benjamin [1 ]
Chetty, Indrin J. [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
来源
关键词
SBRT; treatment planning; Monte Carlo; IMRT; lung; BODY RADIATION-THERAPY; CLINICAL IMPLEMENTATION; CONFORMAL RADIOTHERAPY; CELL-DENSITY; ORGAN MOTION; PHOTON; SYSTEM; CANCER; VERIFICATION; VALIDATION;
D O I
10.1120/jacmp.v13i6.4007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Current commercially available planning systems with Monte Carlo (MC)-based final dose calculation in IMRT planning employ pencil-beam (PB) algorithms in the optimization process. Consequently, dose coverage for SBRT lung plans can feature cold-spots at the interface between lung and tumor tissue. For lung wall (LW)-seated tumors, there can also be hot spots within nearby normal organs (example: ribs). This study evaluated two different practical approaches to limiting cold spots within the target and reducing high doses to surrounding normal organs in MC-based IMRT planning of LW-seated tumors. First, "iterative reoptimization", where the MC calculation (with PB-based optimization) is initially performed. The resultant cold spot is then contoured and used as a simultaneous boost volume. The MC-based dose is then recomputed. The second technique uses noncoplanar beam angles with limited path through lung tissue. Both techniques were evaluated against a conventional coplanar beam approach with a single MC calculation. In all techniques the prescription dose was normalized to cover 95% of the PTV. Fifteen SBRT lung cases with LW-seated tumors were planned. The results from iterative reoptimization showed that conformity index (CI) and/or PTV dose uniformity (U-PTV) improved in 12/15 plans. Average improvement was 13%, and 24%, respectively. Nonimproved plans had PTVs near the skin, trachea, and/or very small lung involvement. The maximum dose to 1cc volume (D1cc) of surrounding OARs decreased in 14/15 plans (average 10%). Using noncoplanar beams showed an average improvement of 7% in 10/15 cases and 11% in 5/15 cases for CI and U-PTV, respectively. The D1cc was reduced by an average of 6% in 10/15 cases to surrounding OARs. Choice of treatment planning technique did not statistically significantly change lung V5. The results showed that the proposed practical approaches enhance dose conformity in MC-based IMRT planning of lung tumors treated with SBRT, improving target dose coverage and potentially reducing toxicities to surrounding normal organs.
引用
收藏
页码:112 / 125
页数:14
相关论文
共 27 条
  • [21] Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study
    Oborn, B. M.
    Ge, Y.
    Hardcastle, N.
    Metcalfe, P. E.
    Keall, P. J.
    MEDICAL PHYSICS, 2016, 43 (01) : 368 - 377
  • [22] Dosimetric Evaluation of Rib Dose in Peripheral Lung Tumors Treated with X-Ray Voxel Monte Carlo (XVMC) Based Lung Stereotactic Body Radiotherapy (SBRT) Following RTOG 0915 Guidelines
    Pokhrel, D.
    Sood, S.
    Badkul, R.
    Jiang, H.
    Kumar, P.
    Wang, F.
    MEDICAL PHYSICS, 2015, 42 (06) : 3407 - 3407
  • [23] 4D STEREOTACTIC LUNG IMRT PLANNING USING MONTE-CARLO DOSE CALCULATIONS ON MULTIPLE RCCT-BASED DEFORMABLE GEOMETRIES
    Soehn, M.
    Van, D.
    Alber, M.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S96 - S96
  • [24] Monte-Carlo Based Treatment Planning May Increase Chest Wall Pain and Rib Fractures in Lung Stereotactic Body Radiation Therapy (SBRT) Patients Treated According to RTOG 0915 Protocol
    Jain, S.
    Sethi, A.
    Melian, E.
    Emami, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S656 - S656
  • [25] Calculation of Jaws-only IMRT (JO-IMRT) dose distributions based on the AAPM TG-119 test cases using Monte Carlo simulation and Prowess Panther treatment planning system
    Oanh, Luong Thi
    Tai, Duong Thanh
    Loan, Truong Thi Hong
    Chow, James C. L.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (12) : 4098 - 4105
  • [26] Modeling of Tumor Control Probability and Rib Toxicity for Peripherally Located Non-Small Cell Lung Cancer (NSCLC) Lesions Treated With Monte Carlo-Based Dose Algorithm
    Pokhrel, D.
    Sood, S. S.
    Shen, X.
    McClinton, C. M.
    Lominska, C. E.
    Badkul, R.
    Jiang, H.
    Mitchell, M. P.
    Kumar, P.
    Wang, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S122 - S123
  • [27] Dosimetric Evaluation On the Reduction of Rib Dose in Stereotactic Body Radiation Therapy (SBRT) of Peripheral Lung Tumors Proximal to Chest Wall Using Field-In-Field (FiF) Technique and Monte Carlo Based Calculation Algorithm
    Jeyakumar, E. Sam
    Demez, N.
    Wang, F.
    Badkul, R.
    MEDICAL PHYSICS, 2017, 44 (06)