The effect of hemodialysis ultrafiltration on changes in whole blood viscosity

被引:7
|
作者
Shirazian, Shayan [1 ]
Rios-Rojas, Liliana [1 ]
Drakakis, James [1 ]
Dikkala, Sudharani [1 ]
Dutka, Paula [1 ]
Duey, Marc [2 ]
Cho, Daniel J. [3 ]
Fishbane, Steven [4 ]
机构
[1] Winthrop Univ Hosp, Div Nephrol, Mineola, NY 11501 USA
[2] ProMetrics Inc, King Of Prussia, PA USA
[3] Rheovector LLC, Pennsauken, NJ USA
[4] Hofstra N Shore LIJ Sch Med, Great Neck, NY USA
关键词
Hemodialysis; ultrafiltration; endothelial; anemia; HEMODYNAMIC SHEAR-STRESS; INTRAVASCULAR ULTRASOUND; PLAQUE RUPTURE; ENDOTHELIUM; PREDICTION; VISCOMETER; EVENTS; STROKE; CELLS; RISK;
D O I
10.1111/j.1542-4758.2012.00671.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Increased whole blood viscosity (WBV) can be injurious to the vascular endothelium and increase the risk of atherothrombotic events. This study examined the effect of hemodialysis ultrafiltration (UF) on WBV, with a focus on high vs. low-volume UF patients. In stable hemodialysis patients, blood was drawn for hematocrit (Hct) and WBV at the start, midpoint, and at the end of dialysis. For analysis, patients were divided into high UF (=2700?mL) or low UF (<2700?mL) groups. A total of 59 patients completed the study. Mean Hct increased during dialysis in both groups. The intradialytic increase in Hct was significantly greater in the high vs. the low UF group (3.2% vs. 1.28%, P?=?0.01), with a significantly higher end-dialysis Hct in the high UF group (40.5% vs. 38%, P?=?0.02). At the end of dialysis, both high shear rate WBV (P?<?0.01) and low shear rate WBV (P?<?0.01) were significantly higher in the high UF compared with the low UF group. There was an approximately two-fold greater increase in high shear rate (P?<?0.01) and low shear rate (P?=?0.01) WBV during dialysis in high vs. low UF groups. The increase in high shear rate WBV during dialysis was significantly correlated with an increase in Hct (R2?=?0.63, P?<?0.01). We found that hemodialysis UF causes a surge in WBV. The surge was of greater magnitude in high than in low UF patients.
引用
收藏
页码:342 / 350
页数:9
相关论文
共 50 条
  • [21] A NON-UNIFORMITY OF CHANGES IN SYSTEMIC BLOOD VOLUME INDUCED BY ULTRAFILTRATION DURING HEMODIALYSIS
    Ookawara, Susumu
    Ito, Kiyonori
    Goto, Sawako
    Ueda, Yuichiro
    Miyazawa, Haruhisa
    Kitano, Taisuke
    Shindo, Mitsunobu
    Kaku, Yoshio
    Hirai, Keiji
    Hoshino, Taro
    Mori, Honami
    Yoshida, Izumi
    Tabei, Kaoru
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [22] PLASMA AND WHOLE BLOOD VISCOSITY CHANGES IN SHOCK AND AFTER DEXTRAN INFUSION
    YAO, ST
    SHOEMAKER, WC
    ANNALS OF SURGERY, 1966, 164 (06) : 973 - +
  • [23] CHANGES IN BLOOD VISCOSITY, YIELD STRESS, AND ECHOCARDIOGRAPHIC PARAMETERS BEFORE AND AFTER HEMODIALYSIS
    Kim, Hanah
    Hur, Mina
    Yang, Hyun Suk
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 55 - 55
  • [24] Whole blood viscosity in thalassemia
    Ongcharoenjai, S
    Oransahid, W
    Somsiri, W
    Siriboon, W
    Fucharoen, S
    Tsuda, I
    Tatsumi, N
    THIRD ASIAN CONGRESS FOR MICROCIRCULATION, 1997, : 183 - 188
  • [25] Effect of high and low ultrafiltration volume during hemodialysis on relative blood volume
    Dasselaar, JJ
    de Jong, PE
    Huisman, RM
    Franssen, CFM
    ASAIO JOURNAL, 2006, 52 (02) : 169 - 173
  • [26] EFFECT OF RED CELL FACTORS ON RELATIVE VISCOSITY OF WHOLE BLOOD
    STRUMIA, MM
    PHILLIPS, M
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1963, 39 (05) : 464 - &
  • [27] EFFECT OF TESTOSTERONE UNDECANOATE ON WHOLE BLOOD VISCOSITY IN CASTRATED RABBIT
    Park, Jong Kwan
    Zhao, Chen
    Moon, Du Geon
    JOURNAL OF SEXUAL MEDICINE, 2013, 10 : 201 - 201
  • [28] EFFECT OF VISCOSITY ON CONCENTRATION POLARIZATION IN ULTRAFILTRATION
    GILL, WN
    WILEY, DE
    FELL, CJD
    FANE, AG
    AICHE JOURNAL, 1988, 34 (09) : 1563 - 1567
  • [29] PLASMA-VOLUME CHANGES INDUCED BY SEQUENTIAL ULTRAFILTRATION-HEMODIALYSIS AND SEQUENTIAL HEMODIALYSIS-ULTRAFILTRATION
    DIMAGGIO, A
    BASILE, C
    SCATIZZI, A
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1987, 10 (05): : 291 - 294
  • [30] EFFECT OF SOLUTION VISCOSITY ON ULTRAFILTRATION FLUX
    WANG, SS