Comparative performance of two methods that assess the quality of international normalized ratio measures

被引:1
|
作者
Shermock, Kenneth M. [1 ]
Tandon, Sangeeta [2 ]
Sorgen, Patrick J. [3 ]
Lavallee, Danielle C. [4 ]
Clarke, William [5 ]
Streiff, Michael B. [6 ]
机构
[1] Johns Hopkins Med Inst, Ctr Pharmaceut Outcomes, Baltimore, MD 21205 USA
[2] Univ Iowa, Coll Pharm, Iowa City, IA 52242 USA
[3] Purdue Univ, Coll Pharm, W Lafayette, IN 47907 USA
[4] Ctr Med Technol Policy, Baltimore, MD USA
[5] Johns Hopkins Sch Med, Dept Pathol, Div Clin Chem, Baltimore, MD USA
[6] Johns Hopkins Sch Med, Div Hematol, Dept Med, Baltimore, MD USA
关键词
Coagulation monitoring; Point-of-care testing; POCT; PT INR; Healthcare quality assurance; AGREEMENT;
D O I
10.1016/j.clinbiochem.2012.01.032
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Two methods, Petersen's error grid analysis and Shermock's method to detect clinically important differences, were recently developed to advance the assessment of analytic performance of point-of-care INR devices. Both methods predict when alternate INR measures lead to different clinical decisions. Our goal was to compare their performance characteristics. Design and methods: Performance characteristics were assessed by comparing the models' predictions to clinical decisions that were directly measured in a previous experiment. Results: Shermock's method (82% of predictions correct) demonstrated superior predictive performance compared with the error grid analysis (75% of predictions correct, p = 0.008). Shermock's method was particularly superior at identifying the clinical decisions that actually disagreed (79% for Shermock's method vs. 47% for error grid). Consequently, Shermock's method was superior at identifying a POC device with poor performance (79% accuracy vs. 70%, p = 0.006). Conclusion: Shermock's method had superior performance characteristics and should be integrated into analytic strategies to assess POC INR devices. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:530 / 534
页数:5
相关论文
共 50 条
  • [31] Point-of-Care International Normalized Ratio Measurements to Assess Eligibility for Thrombolysis in Acute Ischemic Stroke: Some Thoughts
    Dangayach, Neha Subhash
    Panchabhai, Tanmay S.
    STROKE, 2010, 41 (05) : E431 - E431
  • [32] Poor agreement among prothrombin time international normalized ratio methods: Comparison of seven commercial reagents
    Horsti, J
    Uppa, H
    Vilpo, JA
    CLINICAL CHEMISTRY, 2005, 51 (03) : 553 - 560
  • [33] Quality assessment of CoaguChek point-of-care international normalized ratio monitors: A note of caution - Response
    Poller, Leon
    Jespersen, Jorgen
    Keown, Michelle
    Ibrahim, Saied
    Tripodi, Armando
    CLINICAL CHEMISTRY, 2007, 53 (08) : 1556 - 1557
  • [34] Improving Quality Measurement for Anticoagulation Adding International Normalized Ratio Variability to Percent Time in Therapeutic Range
    Razouki, Zayd
    Ozonoff, Al
    Zhao, Shibei
    Jasuja, Guneet K.
    Rose, Adam J.
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2014, 7 (05): : 664 - 669
  • [35] QUALITY MANAGEMENT METHODS AND ITS RELATION TO SUPPLIER PERFORMANCE MEASURES
    Kafel, Piotr
    Rogala, Piotr
    Urbaniak, Maciej
    INTERNATIONAL JOURNAL FOR QUALITY RESEARCH, 2024, 18 (01) : 65 - 78
  • [36] Application of Servqual and Servperf Methods to Assess the Quality of Teaching Services - Comparative Analysis
    Czajkowska, Agnieszka
    Manuela, Ingaldi
    MANUFACTURING TECHNOLOGY, 2021, 21 (03): : 294 - 305
  • [37] Comparative performance of two reversing bowen ratio measurement systems
    McCaughey, J.H.
    Mullins, D.W.
    Publicover, M.
    Journal of Atmospheric and Oceanic Technology, 1987, 4 (04) : 724 - 730
  • [38] Performance of point-of-care international normalized ratio measurement to diagnose trauma-induced coagulopathy
    Mistral, Thomas
    Boue, Yvonnick
    Bosson, Jean-Luc
    Manhes, Pauline
    Greze, Jules
    Brun, Julien
    Albaladejo, Pierre
    Payen, Jean-Francois
    Bouzat, Pierre
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2017, 25
  • [39] Point-of-Care International Normalized Ratio Measurements to Assess Eligibility for Thrombolysis in Acute Ischemic Stroke: Some Thoughts Response
    Rizos, Timolaos
    Veltkamp, Roland
    STROKE, 2010, 41 (05) : E432 - E432
  • [40] Performance of point-of-care international normalized ratio measurement to diagnose trauma-induced coagulopathy
    Thomas Mistral
    Yvonnick Boué
    Jean-Luc Bosson
    Pauline Manhes
    Jules Greze
    Julien Brun
    Pierre Albaladejo
    Jean-François Payen
    Pierre Bouzat
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 25