Performance of fiber beam-column elements in the seismic analysis of a lightly reinforced shear wall

被引:20
|
作者
Martinelli, Luca [1 ]
Martinelli, Paolo [2 ]
Mulas, Maria Gabriella [1 ]
机构
[1] Politecn Milan, Dept Struct Engn, I-20133 Milan, Italy
[2] Politecn Milan, Dept Struct Engn, I-23900 Lecce, Italy
关键词
R/C shear wall; Fiber beam-column element; Shaking table test; Shear effects; MULTISCALE MODELING APPROACH; NONLINEAR-ANALYSIS; CONFINED CONCRETE; PUSHOVER ANALYSIS; R/C FRAMES; BEHAVIOR; FORMULATION; CONCLUSIONS;
D O I
10.1016/j.engstruct.2012.11.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work investigates the capability of two different fiber beam-column finite elements in simulating the dynamic response of a shear wall tested on a shaking table. The two elements account for the axial force-bending moment interaction in a comparable way. The first element can be considered as representative of a class of elements widely available to design engineers for nonlinear (either static or dynamic) analyses. The second element is more refined (and complex) and is specifically derived to reproduce the shear-flexure interaction. The specimen under study is one of the two 5-story, 1/3rd-scale, reinforced concrete (R/C) shear walls, which was subjected to a sequence of accelerograms during the CAMUS I program. The wall was designed according to the French code PS92 and is representative of large lightly reinforced walls, as defined in the Eurocode 8 standard. The measured response is used to assess the benefits and limitations of all the proposed structural models and the adopted finite element formulations; the relevant effects of shear in the response of the specimen are addressed and discussed. Important recommendations on the use of fiber beam-column elements for studying existing R/C structures, which do not comply with the flexure dominated paradigm of walls in the most recent code specifications, are provided. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:345 / 359
页数:15