Benefits of High-Pitch 128-Slice Dual-Source Computed Tomography for Planning of Transcatheter Aortic Valve Implantation

被引:15
|
作者
Plank, Fabian [1 ]
Friedrich, Guy
Bartel, Thomas
Mueller, Silvana
Bonaros, Nikolaos
Heinz, Anneliese
Klauser, Andrea
Cartes-Zumelzu, Fabiola
Grimm, Michael
Feuchtner, Gudrun
机构
[1] Innsbruck Med Univ, Dept Radiol, A-6020 Innsbruck, Austria
来源
ANNALS OF THORACIC SURGERY | 2012年 / 94卷 / 06期
关键词
CT ANGIOGRAPHY; REPLACEMENT; ECHOCARDIOGRAPHY; ROOT;
D O I
10.1016/j.athoracsur.2012.06.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcatheter aortic valve implantation (TAVI) has emerged as an alternative treatment for high-risk and inoperable patients. Advanced multimodality imaging, including computed tomography (CT), plays a key role for optimized planning of TAVI. Methods. Forty-nine patients (25 women; age, 82.3 +/- 8.8 year) with severe aortic stenosis scheduled for TAVI were examined with 128-slice high-pitch dual-source prospective aortoiliac CT angiography (CTA). The 3-coronary-sinus-alignment (3-CSA) plane, comprising left and right anterior oblique and craniocaudal projection, was defined from three-dimensional volume-rendered technique data sets and compared with the intraoperative angiographic plane (deployment plane) used for device implantation. A tolerance level of +/- 5-degree deviation was acceptable. Volume of intraoperative iodine contrast agent was compared before and after the implementation of the 3-CSA plane estimation by CT. Results. All 49 patients underwent TAVI, during which 6 CoreValves (Medtronic, Minneapolis, MN) and 43 Sapien valves (Edwards Lifesciences, Irvine, CA) were successfully implanted using transapical (n = 29), transfemoral (n = 17), and transaxillary access (n = 4). No severe complications occurred. In 47 patients (96%), CTA correctly predicted the 3-CSA plane used for device implantation. Mean left anterior oblique by CTA was 5.3 +/- 6.5 degrees and craniocaudal was -1.3 +/- 10.1 degrees. Mean left anterior oblique deviation between CTA and the intraoperative projection was 2.1 +/- 2.7 degrees and craniocaudal was 1.7 +/- 3.0 degrees. Ostium heights of the right and left coronary arteries were 12 +/- 1.9 and 12.9 +/- 3.3 mm. No over-stenting occurred in left coronary artery ostia of 8 mm or more. Contrast volume was reduced from 81.8 +/- 25.6 to 59.4 +/- 40.2 mL (p = 0.05) when using 3-CSA plane estimation by CT for final prosthesis implantation plane. Conclusions. Aortoiliac high-pitch 128-slice dual-source CT contributes to TAVI planning, including reliable prediction of the 3-CSA valve deployment plane, which saves contrast volume during the procedure and may facilitate correct valve placement.
引用
收藏
页码:1961 / 1966
页数:6
相关论文
共 50 条
  • [31] Feasibility study of using low-kilovoltage, prospective gating, high-pitch, dual-source computed tomography prior to transcatheter aortic valve replacement: analysis of image quality and radiation dose
    Ma, Yanhe
    Fu, Bo
    Yu, Anhong
    Yang, Yapeng
    Rajiah, Prabhakar Shantha
    Zhang, Hong
    [J]. JOURNAL OF THORACIC DISEASE, 2023, 15 (12) : 6848 - 6857
  • [32] DIAGNOSTIC ACCURACY OF 128-SLICE DUAL-SOURCE CT USING HIGH-PITCH SPIRAL MODE IN ASSESSMENT OF CORONARY ARTERY STENT IMAGING COMPARISON WITH INVASIVE CORONARY ANGIOGRAPHY
    Yang Xia
    Chen Yundai
    [J]. HEART, 2012, 98 : E290 - E290
  • [33] Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation
    Chan Kue Park
    Ki Seok Choo
    Ung Bae Jeon
    Seung Kug Baik
    Yong Woo Kim
    Tae Un Kim
    Chang Won Kim
    Yeon Ju Jeong
    Dong Wook Jeong
    Soo Jin Lim
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 47 - 51
  • [34] 128-slice dual-source CT coronary angiography with prospectively electrocardiography-triggered high-pitch spiral mode: radiation dose, image quality, and diagnostic acceptability
    Matsubara, Kosuke
    Sakuda, Keita
    Nunome, Haruka
    Takata, Tadanori
    Koshida, Kichiro
    Gabata, Toshifumi
    [J]. ACTA RADIOLOGICA, 2016, 57 (01) : 25 - 32
  • [35] Clinical validation of dual-source dual-energy computed tomography (DECT) for coronary and valve imaging in patients undergoing transcatheter aortic valve implantation (TAVI)
    Mahoney, R.
    Pavitt, C. W.
    Gordon, D.
    Park, B.
    Rubens, M. B.
    Nicol, E. D.
    Padley, S. P.
    [J]. CLINICAL RADIOLOGY, 2014, 69 (08) : 786 - 794
  • [36] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Ghadri, Jelena R.
    Kueest, Silke M.
    Goetti, Robert
    Fiechter, Michael
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Kuhn, Felix P.
    Pietsch, Carsten
    von Schulthess, Patrick
    Gaemperli, Oliver
    Templin, Christian
    Kaufmann, Philipp A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1217 - 1225
  • [37] High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization
    Karlo, Christoph
    Leschka, Sebastian
    Goetti, Robert Paul
    Feuchtner, Gudrun
    Desbiolles, Lotus
    Stolzmann, Paul
    Plass, Andre
    Falk, Volkmar
    Marincek, Borut
    Alkadhi, Hatem
    Baumueller, Stephan
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (01) : 205 - 212
  • [38] Dual Left Anterior Descending Coronary Artery Diagnosed with 128-slice Dual-source CT
    Duarte, Ricardo
    Miranda, Diana
    Costa, Joao C.
    Oliveira, Joao
    Teixeira, Dinis
    Fernandez-Perez, Gabriel C.
    [J]. HEART LUNG AND CIRCULATION, 2011, 20 (09): : 605 - 605
  • [39] High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization
    Christoph Karlo
    Sebastian Leschka
    Robert Paul Goetti
    Gudrun Feuchtner
    Lotus Desbiolles
    Paul Stolzmann
    Andre Plass
    Volkmar Falk
    Borut Marincek
    Hatem Alkadhi
    Stephan Baumüller
    [J]. European Radiology, 2011, 21 : 205 - 212
  • [40] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Jelena R. Ghadri
    Silke M. Küest
    Robert Goetti
    Michael Fiechter
    Aju P. Pazhenkottil
    Rene N. Nkoulou
    Felix P. Kuhn
    Carsten Pietsch
    Patrick von Schulthess
    Oliver Gaemperli
    Christian Templin
    Philipp A. Kaufmann
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1217 - 1225