Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study

被引:12
|
作者
Perveen, Shuhana [1 ]
Unwin, Danielle [1 ]
Shetty, Amith Loknath [1 ]
机构
[1] Westmead Hosp, Emergency Dept, Sydney, NSW 2145, Australia
关键词
D-dimer; Point of care systems; Pulmonary embolism; Bioequivalence; Length of stay; VENOUS THROMBOEMBOLISM; OUTPATIENTS; ACCURACY;
D O I
10.3343/alm.2013.33.1.34
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: D-dimer is used widely as a diagnostic aid in low- and moderate-risk patients with suspected venous thromboembolism (VTE). While our laboratory utilizes VIDAS D-dimer analyzer (bioMerieux SA, France), our emergency department (ED) recently procured a D-dimer analyzer AQT90 FLEX (Radiometer Medical ApS, Denmark) for point of care testing (FOOT) to facilitate patient management. We aimed to determine whether the time taken to receive D-dimer results using the 2 different analyzers differed significantly and to quantify the limits of agreement between the results of the 2 methods measured on the same patient. Methods: Adult patients presenting to the ED and requiring diagnostic workup for suspected VTE were included in this prospective observational study. Patients underwent simultaneous D-dimer measurements using the 2 different analyzers. Results: The paired results from 104 patients were analyzed. The median time for the D-dimer results from triage by VIDAS was 258 min (Inter-quartile range [IQR], 173-360) and by FOOT was 146 min (IQR, 55-280.5); the median time difference was 101.5 min (IQR, 82-125.5). On an average, FOOT D-dimer values were 15% lower on the same sample (limits of agreement, 34-213%). FOOT predicted 83% of VIDAS positive results (sensitivity, 83.3% [95% confidence interval (CI), 70.4-91.3%]; specificity, 100% [95% CI, 93.6-100%]). All patients with positive imaging were identified correctly by both methods. Conclusions: FOOT delivers D-dimer results in significantly shorter turnaround times than pathology services; however, poor bioequivalence between VIDAS and FOOT raises the issue of acceptability for use in the ED.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [21] Bedside measurement of D-dimer in the identification of bacteremia in the Emergency Department
    Quick, G
    Eisenberg, P
    JOURNAL OF EMERGENCY MEDICINE, 2000, 19 (03): : 217 - 223
  • [22] The use of a D-dimer as a screening test in the emergency department - Reply
    Hogg, K
    Dawson, D
    Mackway-Jones, K
    ANNALS OF EMERGENCY MEDICINE, 2006, 47 (05) : 507 - 507
  • [23] Can D-dimer testing help emergency department physicians to detect acute aortic dissections?
    Ersel, Murat
    Aksay, Ersin
    Kiyan, Selahattin
    Bayraktaroglu, Selen
    Yuruktumen, Aslihan
    Ozsarac, Murat
    Calkavur, Tanzer
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2010, 10 (05): : 434 - 439
  • [24] USE OF THE D-DIMER FOR DETECTING PULMONARY EMBOLISM IN THE EMERGENCY DEPARTMENT
    Glober, Nancy
    Tainter, Christopher R.
    Brennan, Jesse
    Darocki, Mark
    Klingfus, Morgan
    Choi, Michelle
    Derksen, Brenna
    Rudolf, Frances
    Wardi, Gabriel
    Castillo, Edward
    Chan, Theodore
    JOURNAL OF EMERGENCY MEDICINE, 2018, 54 (05): : 585 - 592
  • [25] Comparison of YEARS and Adjust-Unlikely D-dimer Testing for Pulmonary Embolism in the Emergency Department
    de Wit, Kerstin
    Al-Haimus, Fayad
    Hu, Yang
    Ikesaka, Rick
    Chan, Noel
    Ibrahim, Quazi
    Klyn, Joshua
    Clayton, Natasha
    Germini, Federico
    ANNALS OF EMERGENCY MEDICINE, 2023, 81 (05) : 558 - 565
  • [26] D-dimer and D-dimer/fibrinogen ratio in predicting pulmonary embolism in patients evaluated in a hospital emergency department
    Kara, H.
    Bayir, A.
    Degirmenci, S.
    Kayis, S. A.
    Akinci, M.
    Ak, A.
    Celik, B.
    Dogru, A.
    Ozturk, B.
    ACTA CLINICA BELGICA, 2014, 69 (04) : 240 - 245
  • [27] Criteria for the safe use of D-dimer testing in emergency department patients with suspected pulmonary embolism: A Multicenter US study
    Kline, JA
    Nelson, RD
    Jackson, RE
    Courtney, DM
    ANNALS OF EMERGENCY MEDICINE, 2002, 39 (02) : 144 - 152
  • [28] Evaluation of an external quality assessment material for D-dimer point of care testing kits
    Kitchen, D. P.
    Munroe-Peart, S.
    Kitchen, S.
    Jennings, I.
    Woods, T. A. L.
    Walker, I. D.
    BRITISH JOURNAL OF HAEMATOLOGY, 2013, 161 : 34 - 34
  • [29] Evaluation of an external quality assessment material for D-dimer point of care testing kits
    Kitchen, D.
    Munroe-Peart, S.
    Kitchen, S.
    Jennings, I
    Woods, T.
    Walker, I
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 381 - 382
  • [30] Evaluation of an external quality assessment material for D-dimer point of care testing kits
    Kitchen, D. P.
    Munroe-Peart, S.
    Kitchen, S.
    Jennings, I.
    Woods, T. A. L.
    Walker, I. D.
    BRITISH JOURNAL OF HAEMATOLOGY, 2011, 153 : 77 - 77