Direct Recordings from the Auditory Cortex in a Cochlear Implant User

被引:15
|
作者
Nourski, Kirill V. [1 ]
Etler, Christine P. [2 ]
Brugge, John F. [1 ,4 ]
Oya, Hiroyuki [1 ]
Kawasaki, Hiroto [1 ]
Reale, Richard A. [1 ,4 ]
Abbas, Paul J. [2 ,3 ]
Brown, Carolyn J. [2 ,3 ]
Howard, Matthew A., III [1 ]
机构
[1] Univ Iowa, Dept Neurosurg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Commun Sci & Disorders, Iowa City, IA 52242 USA
[4] Univ Wisconsin, Dept Psychol, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
averaged evoked potential; cortical plasticity; electrical stimulation; electrocorticography; high gamma; intracranial electrophysiology; CONGENITALLY DEAF CATS; REPETITIVE TRANSIENTS; TEMPORAL ENVELOPE; CHANGE COMPLEX; RESPONSES; HEARING; POTENTIALS; MATURATION; PLASTICITY; CHILDREN;
D O I
10.1007/s10162-013-0382-3
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Electrical stimulation of the auditory nerve with a cochlear implant (CI) is the method of choice for treatment of severe-to-profound hearing loss. Understanding how the human auditory cortex responds to CI stimulation is important for advances in stimulation paradigms and rehabilitation strategies. In this study, auditory cortical responses to CI stimulation were recorded intracranially in a neurosurgical patient to examine directly the functional organization of the auditory cortex and compare the findings with those obtained in normal-hearing subjects. The subject was a bilateral CI user with a 20-year history of deafness and refractory epilepsy. As part of the epilepsy treatment, a subdural grid electrode was implanted over the left temporal lobe. Pure tones, click trains, sinusoidal amplitude-modulated noise, and speech were presented via the auxiliary input of the right CI speech processor. Additional experiments were conducted with bilateral CI stimulation. Auditory event-related changes in cortical activity, characterized by the averaged evoked potential and event-related band power, were localized to posterolateral superior temporal gyrus. Responses were stable across recording sessions and were abolished under general anesthesia. Response latency decreased and magnitude increased with increasing stimulus level. More apical intracochlear stimulation yielded the largest responses. Cortical evoked potentials were phase-locked to the temporal modulations of periodic stimuli and speech utterances. Bilateral electrical stimulation resulted in minimal artifact contamination. This study demonstrates the feasibility of intracranial electrophysiological recordings of responses to CI stimulation in a human subject, shows that cortical response properties may be similar to those obtained in normal-hearing individuals, and provides a basis for future comparisons with extracranial recordings.
引用
收藏
页码:435 / 450
页数:16
相关论文
共 50 条
  • [41] COCHLEAR IMPLANT AS AN INTERVENTION IN PATIENTS WITH AUDITORY NEUROPATHY
    JI Fei
    LI Jianan
    YANG Shiming
    Journal of Otology, 2013, 8 (02) : 77 - 81
  • [42] Satisfaction of Children with Auditory Neuropathy and Cochlear Implant
    de Carvalho, Guilherme Machado
    Zago, Thiago M.
    Ramos, Priscila Z.
    Castilho, Arthur M.
    Guimaraes, Alexandre C.
    Sartorato, Edi L.
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2015, 11 (03): : 229 - 235
  • [43] Auditory cortical plasticity in cochlear implant users
    Glennon, Erin
    Svirsky, Mario A.
    Froemke, Robert C.
    CURRENT OPINION IN NEUROBIOLOGY, 2020, 60 : 108 - 114
  • [44] AUDITORY AND COMMUNICATIVE LEARNING BY THE USE OF COCHLEAR IMPLANT
    BUCHER, PO
    MATHIS, A
    ARNOLD, W
    HNO, 1989, 37 (06) : 250 - 254
  • [45] Direct Cochlear Recordings in Humans Show a Theta Rhythmic Modulation of Auditory Nerve Activity by Selective Attention
    Gehmacher, Quirin
    Reisinger, Patrick
    Hartmann, Thomas
    Keintzel, Thomas
    Rosch, Sebastian
    Schwarz, Konrad
    Weisz, Nathan
    JOURNAL OF NEUROSCIENCE, 2022, 42 (07): : 1343 - 1351
  • [46] The Effect of Cochlear Coverage on Auditory and Speech Performance in Cochlear Implant Patients
    Doubi, Aseel
    Almuhawas, Fida
    Alzhrani, Farid
    Doubi, Motaz
    Aljutaili, Hamad
    Hagr, Abdulrahman
    OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : 602 - 607
  • [47] Auditory perception in pediatric cochlear implant users with cochlear nerve hypoplasia
    Uzun, Erva Degirmenci
    Batuk, Merve Ozbal
    D'Alessandrob, Hilal Dincer
    Sennaroglu, Gonca
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2022, 160
  • [48] Direct Parasagittal Magnetic Resonance Imaging of the Internal Auditory Canal to Determine Cochlear or Auditory Brainstem Implant Candidacy in Children
    Noij, Kimberley S.
    Remenschneider, Aaron K.
    Kozin, Elliott D.
    Puram, Sidharth
    Herrmann, Barbara
    Cohen, Michael
    Cunnane, Mary Beth
    Lee, Daniel J.
    LARYNGOSCOPE, 2015, 125 (10): : 2382 - 2385
  • [49] Cochlear Implant Use Following Neonatal Deafness Influences the Cochleotopic Organization of the Primary Auditory Cortex in Cats
    Fallon, James B.
    Irvine, Dexter R. F.
    Shepherd, Robert K.
    JOURNAL OF COMPARATIVE NEUROLOGY, 2009, 512 (01) : 101 - 114
  • [50] A monosynaptic pathway from dorsal cochlear nucleus to auditory cortex in rat
    Anderson, Lucy A.
    Lzquierdo, Marco A.
    Antunes, Flora M.
    Malmierca, Manuel S.
    NEUROREPORT, 2009, 20 (05) : 462 - 466