Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures

被引:21
|
作者
Oberst, Michael [1 ]
Hauschild, Oliver [2 ]
Konstantinidis, Lukas [2 ]
Suedkamp, Norbert P. [2 ]
Schmal, Hagen [2 ]
机构
[1] Ostalb Klinikum Aalen, Clin Orthopaed Trauma & Spine Surg, D-73430 Aalen, Germany
[2] Univ Hosp Freiburg, Dept Orthopaed & Traumatol, Freiburg, Germany
来源
关键词
Acetabulum; fracture; navigation; ORIF; OPERATIVE TREATMENT; SCREW PLACEMENT; CLASSIFICATION; SURGERY; COMPLEX; POSITION;
D O I
10.1097/TA.0b013e318254308f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: This study was conducted to evaluate whether intraoperative procedure and/or early postoperative results after open reduction and internal fixation (ORIF) of displaced acetabulum fractures are influenced by the use of a three-dimensional (3D) image intensifier in combination with a navigation system. METHODS: From January 2004 until December 2008, all patients with acetabular fractures were followed prospectively. From January 2004 until October 2006, all operations were performed under fluoroscopic control using a conventional two-dimensional image intensifier. Since October 2006, we regularly operate acetabular fractures with the intraoperative use of a navigation system and a 3D image intensifier. Pre- and postoperative computed tomography scans of the affected hip were obtained in all patients as were standard anterior-posterior radiographs and ala-and obturator views. All data collection was performed according to the guidelines of the "German Pelvic fracture study group." RESULTS: In total, 68 patients with acetabular fractures were included in the study. A conventional image intensifier was used in 37 patients (group A) and a 3D image-based navigation was used in the remaining 31 patients (group B). In the navigated group, seven patients were assessed incapable of partial weight bearing. These patients underwent computer-assisted percutaneous screwing of their acetabular fracture. Using a navigation system in combination with a 3D image intensifier for ORIF of displaced acetabular fractures led to a significant increase in skin-to-skin time. Postoperative radiolographic analysis revealed an improvement in the quality of fracture reduction in the 3D navigation group. Navigation in combination with the 3D images of the ISO-C 3D limited the need for extended approaches. In addition, the complication rate in the navigated group was significantly lower. CONCLUSION: We support the use of navigation systems and a 3D image intensifier as helpful tools during ORIF of displaced acetabular fractures. (J Trauma Acute Care Surg. 2012; 73: 950-956. Copyright (C) 2012 by Lippincott Williams & Wilkins)
引用
收藏
页码:950 / 956
页数:7
相关论文
共 50 条
  • [41] Postoperative radiographs after open reduction and internal fixation of mandibular fractures: clinical need or unnecessary radiation?
    Dewi, Ffion
    Henry, Alastair
    Bhatia, Satyajeet
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (03): : 312 - 315
  • [42] Letter regarding "Open reduction and internal fixation alone versus open reduction and internal fixation plus total hip arthroplasty for displaced acetabular fractures in patients older than 60 years: A prospective clinical trial"
    Oide, Shiho
    Banno, Masahiro
    Saitsu, Akihiro
    Saka, Natsumi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (03): : 1299 - 1300
  • [43] The Combined Hip Procedure: Open Reduction Internal Fixation Combined With Total Hip Arthroplasty for the Management of Acetabular Fractures in the Elderly
    Herscovici, Dolfi, Jr.
    Lindvall, Eric
    Bolhofner, Brett
    Scaduto, Julia M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (05) : 291 - 296
  • [44] Management of multiple and displaced mandibular fractures in a pediatric patient sans mandibular immobilization, sans open reduction and internal fixation
    Panneerselvam, Elavenil
    Ravikumar, Chandini
    Rajan, Trishala Annamalai
    Balasubramanian, Sasikala
    Raja, V. B. Krishnakumar
    CHINESE JOURNAL OF TRAUMATOLOGY, 2024, 27 (05) : 284 - 287
  • [45] Management of multiple and displaced mandibular fractures in a pediatric patient sans mandibular immobilization, sans open reduction and internal fixation
    Panneerselvam Elavenil
    Ravikumar Chandini
    Annamalai Rajan Trishala
    Balasubramanian Sasikala
    Raja V.B. Krishnakumar
    中华创伤杂志英文版, 2024, 27 (05)
  • [46] The Long-Term Outcome of Open Reduction and Internal Fixation of Stable Displaced Isolated Partial Articular Fractures of the Radial Head
    Lindenhovius, Anneluuk L. C.
    Fesch, Quinten
    Ring, David
    Kloen, Peter
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 67 (01): : 143 - 146
  • [47] Correlation between Clinical Outcome and Radiologic Features After Open Reduction and Internal Fixation of Calcaneal Fractures
    Hashemi, Seyed Ali
    Mehboudi, Mohammad
    Hoveidaei, Amir Human
    Vosoughi, Amir Reza
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2024, 114 (01)
  • [48] Three-dimensional movement analysis after internal fixation of pelvic ring fractures -: A computer simulation
    Culemann, U
    Pohlemann, T
    Hüfner, T
    Gänsslen, A
    UNFALLCHIRURG, 2000, 103 (11): : 965 - 971
  • [49] Assessment of the curative effects of open reduction and internal fixation with bone grafting on calcaneal displaced intra-articular fractures
    Xu, Haining
    Lu, Jianshu
    Li, Liang
    Tian, Hongyan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 11169 - 11176
  • [50] Risk factors for increased postoperative drainage of calcaneal fractures after open reduction and internal fixation: An observational study
    Zhang, Zitao
    Wang, Zhen
    Zhang, Yan
    Qiu, Xusheng
    Chen, Yixin
    MEDICINE, 2018, 97 (32)