Reliability of echo-Doppler and helical computed tomography angiography for the diagnosis of renal artery stenosis

被引:0
|
作者
Equine, O
Bérégi, JP
Mounier-Véhier, C
Gautier, C
Desmoucelles, F
Carré, A
机构
[1] Ctr Hosp Reg & Univ Lille, Hop Cardiol, Serv Med Interne & Hypertens Arterielle, F-59037 Lille, France
[2] Ctr Hosp Reg & Univ Lille, Hop Cardiol, Serv Radiol Intervent, F-59037 Lille, France
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine the sensitivity and specificity of two non invasive methods for the diagnosis of renal artery stenosis, compared with renal angiography, Retrospective analysis of 113 hypertensive patients who underwent renal angiography permitted us to evaluate the results of echo-Doppler (n = 53) and helical computed tomography angiography (n = 50). Regarding echo-Doppler, sensitivity and specificity were 0.75 and 0.86 respectively (40 true positives/53 stenoses, and negative result in 38/44 normal arteries). Regarding helical CT angiography, these Values were 0.94 and 0.95 respectively (positive result in 45/48 stenoses, and 41 true negatives/43 normal arteries). These results suggest that echo-Doppler and helical CT angiography are two reliable methods for the diagnosis of renal artery stenosis. Thus, renal angiography could be reserved for patients who may require percutaneous transluminal renal angioplasty.
引用
收藏
页码:1043 / 1045
页数:3
相关论文
共 50 条
  • [41] Value of Doppler parameters in the diagnosis of renal artery stenosis
    Miralles, M
    Cairols, M
    Cotillas, J
    Gimenez, A
    Santiso, A
    JOURNAL OF VASCULAR SURGERY, 1996, 23 (03) : 428 - 435
  • [42] Noninvasive detection of coronary artery stenosis by multislice helical computed tomography
    Knez, A
    Becker, C
    Ohnesorge, B
    Haberl, R
    Reiser, M
    Steinbeck, G
    CIRCULATION, 2000, 101 (23) : E221 - E222
  • [43] Helical computed tomography angiography in the evaluation of Chinese living renal donors
    Tang, S
    Chan, J
    Tso, WK
    Ho, KK
    Chan, TM
    Lai, KN
    BJU INTERNATIONAL, 1999, 83 (04) : 387 - 391
  • [44] Helical CT angiography compared with arteriography in the detection of renal artery stenosis
    Beregi, JP
    Elkohen, M
    Deklunder, G
    Artaud, D
    Coullet, JM
    Wattinne, L
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 495 - 501
  • [45] Computed tomography angiography for renal artery stenosis in children: a flip flop isn’t always bad
    James S. Donaldson
    Pediatric Radiology, 2021, 51 : 383 - 384
  • [46] Computed tomography angiography for renal artery stenosis in children: a flip flop isn't always bad
    Donaldson, James S.
    PEDIATRIC RADIOLOGY, 2021, 51 (03) : 383 - 384
  • [47] Reliability of intrarenal Doppler sonographic parameters of renal artery stenosis
    Demirpolat, G
    Özbek, SS
    Parildar, M
    Oran, I
    Memis, A
    JOURNAL OF CLINICAL ULTRASOUND, 2003, 31 (07) : 346 - 351
  • [48] PITFALLS IN THE ECHO-DOPPLER DIAGNOSIS OF PROSTHETIC VALVE DISORDERS
    ZABALGOITIA, M
    GARCIA, M
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1993, 10 (02): : 203 - 212
  • [49] Comparison of Measurement and Grading of Carotid Stenosis with Computed Tomography Angiography and Doppler Ultrasound
    Birmpili, Panagiota
    Porter, Laura
    Shaikh, Usman
    Torella, Francesco
    ANNALS OF VASCULAR SURGERY, 2018, 51 : 217 - 224
  • [50] RELIABILITY OF DOPPLER ULTRASOUND DIAGNOSIS IN CAROTID-ARTERY STENOSIS
    PERRIN, G
    GOUTELLE, A
    PIERLUCA, P
    CHACORNAC, R
    ALLEGRE, GE
    NEUROCHIRURGIE, 1977, 23 (03) : 215 - 225