Evaluating a Hybrid Circuit Topology for Fault-Ride through in DFIG-Based Wind Turbines

被引:12
|
作者
Saeed, Sarmad [1 ]
Asghar, Rafiq [2 ]
Mehmood, Faizan [3 ]
Saleem, Haider [4 ]
Azeem, Babar [5 ]
Ullah, Zahid [6 ]
机构
[1] Univ Alabama Birmingham, Dept Comp Sci, Birmingham, AL 35294 USA
[2] Univ Engn & Technol, Dept Elect Engn, Peshawar 25000, Pakistan
[3] Univ Engn & Technol, Dept Elect Engn, Taxila 47050, Pakistan
[4] Univ Alabama Birmingham, Dept Elect & Comp Engn, Birmingham, AL 35294 USA
[5] Carinthia Univ Appl Sci, Dept Elect Energy & Mobil Syst, A-9524 Villach, Austria
[6] UMT Lahore Sialkot Campus, Dept Elect Engn, Sialkot 51310, Pakistan
关键词
doubly fed induction generator; fault ride-through; grid faults; renewable energy sources; LOW-VOLTAGE RIDE; CONTROL STRATEGY; SYSTEM; ENHANCEMENT; ALGORITHM;
D O I
10.3390/s22239314
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Large-scale wind power integration has raised concerns about the reliability and stability of power systems. The rotor circuit of a doubly fed induction generator (DFIG) is highly vulnerable to unexpected voltage dips, which can cause considerable electromotive force in the circuit. Consequently, the DFIG must fulfil the fault-ride through (FRT) criteria to ensure the system's performance and contribute to voltage regulation during severe grid outages. This paper provides a hybrid solution for DFIG wind turbines with FRT capabilities, using both a modified switch-type fault current limiter (MSFTCL) and a direct current (DC) chopper. The proposed system has the merit of keeping the rotor current and the DC-link voltage within the permissible limits, enhancing the FRT capability of generators. Moreover, the boundness of supply voltage into its reference value ensures dynamic stability during symmetric and asymmetric grid failures. Further, electromagnetic torque variations are significantly reduced during fault events. Finally, the performance validation of the proposed scheme is performed in a simulation setup, and the results are compared with the existing sliding mode control (SMC) and proportional-integral (PI) controller-based approaches. The comparison results show that a hybrid strategy with advanced controllers provides superior performance for all critical parameters.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Voltage Ride-Through Capability Verification of DFIG-Based Wind Turbines Using Reachability Analysis
    Pico, Hugo N. Villegas
    Aliprantis, Dionysios C.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1387 - 1398
  • [32] An Improved Fault Ride Through Scheme and Control Strategy for DFIG-Based Wind Energy Systems
    Musarrat, Md Nafiz
    Fekih, Afef
    Islam, Md Rabiul
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)
  • [33] Fault ride through constrained protection scheme for distribution networks with DFIG-based wind parks
    Yoosefian, Davood
    Askarian-Abyaneh, Hossein
    Kheshti, Mostafa
    Li, Qi
    Terzija, Vladimir
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2023, 215
  • [34] Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm
    Dosoglu, M. Kenan
    [J]. NONLINEAR DYNAMICS, 2017, 89 (04) : 2683 - 2694
  • [35] Investigation of Fault Ride-through Behavior of DFIG-based Wind Energy Conversion Systems
    Tourou, Pavlos
    Sourkounis, Constantinos
    [J]. 2014 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON 2014), 2014, : 87 - 93
  • [36] Improving the LVRT Capability of the DFIG-Based Wind Turbines during Fault
    Madani, Seyed Mohammad
    Sadeghi, Ramtin
    Abadi, Behnaz Kharkan Mehdi
    [J]. 2015 6TH POWER ELECTRONICS, DRIVES SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC), 2015, : 503 - 508
  • [37] Active Damping Control of DFIG Wind Turbines during Fault Ride Through
    Xu, Hao
    Xu, Honghua
    Chen, Liang
    Wenske, Jan
    [J]. 2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [38] Nonlinear Backstepping Controller Design for Improving Fault Ride Through Capabilities of DFIG-Based Wind Farms
    Roy, T. K.
    Mahmud, M. A.
    Oo, A. M. T.
    [J]. 2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [39] Fault Ride-Through Enhancement of DFIG-Based Wind Generation Considering Unbalanced and Distorted Conditions
    Leon, Andres E.
    Manuel Mauricio, Juan
    Solsona, Jorge A.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (03) : 775 - 783
  • [40] Fault ride-through capability improvement in a DFIG-based wind turbine using modified ADRC
    Mosayyebi, Seyed Reza
    Shahalami, Seyed Hamid
    Mojallali, Hamed
    [J]. PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2022, 7 (01)