Evaluating a Hybrid Circuit Topology for Fault-Ride through in DFIG-Based Wind Turbines

被引:12
|
作者
Saeed, Sarmad [1 ]
Asghar, Rafiq [2 ]
Mehmood, Faizan [3 ]
Saleem, Haider [4 ]
Azeem, Babar [5 ]
Ullah, Zahid [6 ]
机构
[1] Univ Alabama Birmingham, Dept Comp Sci, Birmingham, AL 35294 USA
[2] Univ Engn & Technol, Dept Elect Engn, Peshawar 25000, Pakistan
[3] Univ Engn & Technol, Dept Elect Engn, Taxila 47050, Pakistan
[4] Univ Alabama Birmingham, Dept Elect & Comp Engn, Birmingham, AL 35294 USA
[5] Carinthia Univ Appl Sci, Dept Elect Energy & Mobil Syst, A-9524 Villach, Austria
[6] UMT Lahore Sialkot Campus, Dept Elect Engn, Sialkot 51310, Pakistan
关键词
doubly fed induction generator; fault ride-through; grid faults; renewable energy sources; LOW-VOLTAGE RIDE; CONTROL STRATEGY; SYSTEM; ENHANCEMENT; ALGORITHM;
D O I
10.3390/s22239314
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Large-scale wind power integration has raised concerns about the reliability and stability of power systems. The rotor circuit of a doubly fed induction generator (DFIG) is highly vulnerable to unexpected voltage dips, which can cause considerable electromotive force in the circuit. Consequently, the DFIG must fulfil the fault-ride through (FRT) criteria to ensure the system's performance and contribute to voltage regulation during severe grid outages. This paper provides a hybrid solution for DFIG wind turbines with FRT capabilities, using both a modified switch-type fault current limiter (MSFTCL) and a direct current (DC) chopper. The proposed system has the merit of keeping the rotor current and the DC-link voltage within the permissible limits, enhancing the FRT capability of generators. Moreover, the boundness of supply voltage into its reference value ensures dynamic stability during symmetric and asymmetric grid failures. Further, electromagnetic torque variations are significantly reduced during fault events. Finally, the performance validation of the proposed scheme is performed in a simulation setup, and the results are compared with the existing sliding mode control (SMC) and proportional-integral (PI) controller-based approaches. The comparison results show that a hybrid strategy with advanced controllers provides superior performance for all critical parameters.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Fault-Ride Through Capability Enhancement of DFIG-Based Wind Turbines by SFCL
    Abdellatif, Walid S. E.
    Alaboudy, Ali H. Kasem
    Azmy, Ahmed M.
    [J]. 2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 1104 - 1109
  • [2] Blackstart and Fault Ride -Through Capability of DFIG-Based Wind Turbines
    Dang, Hoang P.
    Pico, Hugo N. Villegas
    [J]. 2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [3] Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines
    Dang, Hoang P.
    Pico, Hugo Villegas N.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (03) : 2060 - 2074
  • [4] Modeling of complete fault ride-through processes for DFIG-Based wind turbines
    Li, Weixing
    Chao, Pupu
    Liang, Xiaodong
    Sun, Yong
    Qi, Jinling
    Chang, Xuefei
    [J]. RENEWABLE ENERGY, 2018, 118 : 1001 - 1014
  • [5] High Voltage Ride-Through of DFIG-based Wind Turbines
    Feltes, C.
    Engelhardt, S.
    Kretschmann, J.
    Fortmann, J.
    Koch, F.
    Erlich, I.
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1477 - 1484
  • [6] A new hybrid multilevel converter for DFIG-based wind turbines fault ride-through and transient stability enhancement
    Arthur E. A. Amorim
    Daniel Carletti
    Jussara F. Fardin
    Lucas F. Encarnação
    Domingos S. L. Simonetti
    [J]. Electrical Engineering, 2020, 102 : 1035 - 1050
  • [7] A new hybrid multilevel converter for DFIG-based wind turbines fault ride-through and transient stability enhancement
    Amorim, Arthur E. A.
    Carletti, Daniel
    Fardin, Jussara F.
    Encarnacao, Lucas F.
    Simonetti, Domingos S. L.
    [J]. ELECTRICAL ENGINEERING, 2020, 102 (02) : 1035 - 1050
  • [8] Improving the Fault Ride-through Capability of DFIG-Based Wind Turbines Using the Dynamic Impedance
    Liang, Yabo
    Cao, Yunzhu
    Li, Lei
    Sheng, Yaru
    Niu, Jian
    He, Jianan
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1185 - 1189
  • [9] Electromagnetic Validation of Fault-Ride Through Capabilities of Wind Turbines
    Rogdakis, G.
    Garcia-Valle, R.
    Arana, I.
    Sharma, R.
    Jensen, K. H.
    [J]. 9TH INTERNATIONAL WORKSHOP ON LARGE-SCALE INTEGRATION OF WIND POWER INTO POWER SYSTEMS AS WELL AS ON TRANSMISSION NETWORKS FOR OFFSHORE WIND POWER PLANTS, 2010, : 771 - 777
  • [10] Fault Ride Through Techniques of DFIG-based Wind Energy Systems
    Fan, Lingling
    Zhu, Chanxia
    Hu, Minqiang
    [J]. PROCEEDINGS OF THE 48TH IEEE CONFERENCE ON DECISION AND CONTROL, 2009 HELD JOINTLY WITH THE 2009 28TH CHINESE CONTROL CONFERENCE (CDC/CCC 2009), 2009, : 6829 - 6834