Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging

被引:0
|
作者
Posse, S
Wiese, S
Gembris, D
Mathiak, K
Kessler, C
Grosse-Ruyken, ML
Elghahwagi, B
Richards, T
Dager, SR
Kiselev, VG
机构
[1] Forschungszentrum Julich, Res Ctr, Inst Med, D-52425 Julich, Germany
[2] Univ Dusseldorf, Dept Psychiat, D-4000 Dusseldorf, Germany
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[4] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
fMRI; BOLD contrast; MR; sensitivity; multi-echo; spectroscopic imaging;
D O I
10.1002/(SICI)1522-2594(199907)42:1<87::AID-MRM13>3.0.CO;2-O
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Improved data acquisition and processing strategies for blood oxygenation level-dependent (BOLD)-contrast functional magnetic resonance imaging (fMRI), which enhance the functional contrast-to-noise ratio (CNR) by sampling multiple echo times in a single shot, are described. The dependence of the CNR an T(2)*, the image encoding time, and the number of sampled echo times are investigated for exponential fitting, echo summation, weighted echo summation, and averaging of correlation maps obtained at different echo times. The method is validated in vivo using visual stimulation and turbo proton echoplanar spectroscopic imaging (turbo-PEPSI), a new single-shot multi-slice MR spectroscopic imaging technique, which acquires up to 12 consecutive echoplanar images with echo times ranging from 12 to 213 msec, Quantitative T(2)*-mapping significantly increases the measured extent of activation and the mean correlation coefficient compared with conventional echoplanar imaging, The sensitivity gain with echo summation, which is computationally efficient provides similar sensitivity as fitting. For all data processing methods sensitivity is optimum when echo times up to 3.2 T(2)* are sampled. This methodology has implications for comparing functional sensitivity at different magnetic field strengths and between brain regions with different magnetic field inhomogeneities. Magn Reson Med 42:87-97, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:87 / 97
页数:11
相关论文
共 50 条
  • [21] Noise removal for Multi-echo MR images using Global Enhancement
    Hong, Seongwook
    Cui, Xuenan
    Li, Shengzhe
    June, Naw Chit Too
    Kwack, Kyu-sung
    Kim, Hakil
    IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC 2010), 2010, : 3616 - 3621
  • [22] Single-Shot Phase-Contrast Imaging with a Single Grating
    Liu, Xin
    Liu, Lang
    Huang, Jianheng
    Lei, Yaohu
    Li, Ji
    PHOTONICS, 2023, 10 (09)
  • [23] Continuous prospectively navigated multi-echo GRE for improved BOLD imaging of the kidneys
    Morrell, Glen Robert
    Jeong, Eun-Kee
    Shi, Xianfeng
    Zhang, Lei
    Lee, Vivian Shu-Ching
    NMR IN BIOMEDICINE, 2019, 32 (05)
  • [24] SINGLE-SHOT DIFFUSION MR-IMAGING WITH HASTE
    SINHA, U
    SINHA, S
    RADIOLOGY, 1995, 197 : 391 - 391
  • [25] An imaging-based method of mapping multi-echo BOLD intracranial pulsatility
    Valsamis, Jake J.
    Luciw, Nicholas J.
    Haq, Nandinee
    Atwi, Sarah
    Duchesne, Simon
    Cameron, William
    MacIntosh, Bradley J.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (01) : 343 - 352
  • [26] Rapid and accurate measurement of transverse relaxation times using a single shot multi-echo echo-planar imaging sequence
    Tyler, DJ
    Moore, RJ
    Marciani, L
    Gowland, PA
    MAGNETIC RESONANCE IMAGING, 2004, 22 (07) : 1031 - 1037
  • [27] Multiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI
    Cohen, Alexander D.
    Nencka, Andrew S.
    Wang, Yang
    PLOS ONE, 2018, 13 (02):
  • [28] Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction
    Wu, Wenchuan
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (01) : 82 - 97
  • [29] MR imaging of the liver: Comparison between single-shot echo-planar and half-Fourier rapid acquisition with relaxation enhancement sequences
    Yamashita, Y
    Tang, Y
    Namimoto, T
    Mitsuzaki, K
    Takahashi, M
    RADIOLOGY, 1998, 207 (02) : 331 - 337
  • [30] Common SENSE (Sensitivity encoding using hardware common to all MR scanners): A new method for single-shot segmented echo planar imaging
    Carmichael, DW
    Priest, AN
    De Vita, E
    Ordidge, RJ
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 402 - 410