Towards in vivo estimation of reaction kinetics using high-throughput metabolomics data: a maximum likelihood approach

被引:1
|
作者
Zhang, Weiruo [1 ]
Kolte, Ritesh [1 ]
Dill, David L. [2 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Comp Sci, Stanford, CA 94305 USA
来源
BMC SYSTEMS BIOLOGY | 2015年 / 9卷
关键词
Relative error; Enzymatic reaction; Parameter estimation; Maximum likelihood; Error-in-all-measurements; In vivo data; MASS-SPECTROMETRY; SACCHAROMYCES-CEREVISIAE; QUANTIFICATION;
D O I
10.1186/s12918-015-0214-7
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: High-throughput assays such as mass spectrometry have opened up the possibility for large-scale in vivo measurements of the metabolome. This data could potentially be used to estimate kinetic parameters for many metabolic reactions. However, high-throughput in vivo measurements have special properties that are not taken into account in existing methods for estimating kinetic parameters, including significant relative errors in measurements of metabolite concentrations and reaction rates, and reactions with multiple substrates and products, which are sometimes reversible. A new method is needed to estimate kinetic parameters taking into account these factors. Results: A new method, InVEst (In Vivo Estimation), is described for estimating reaction kinetic parameters, which addresses the specific challenges of in vivo data. InVEst uses maximum likelihood estimation based on a model where all measurements have relative errors. Simulations show that InVEst produces accurate estimates for a reversible enzymatic reaction with multiple reactants and products, that estimated parameters can be used to predict the effects of genetic variants, and that InVEst is more accurate than general least squares and graphic methods on data with relative errors. InVEst uses the bootstrap method to evaluate the accuracy of its estimates. Conclusions: InVEst addresses several challenges of in vivo data, which are not taken into account by existing methods. When data have relative errors, InVEst produces more accurate and robust estimates. InVEst also provides useful information about estimation accuracy using bootstrapping. It has potential applications of quantifying the effects of genetic variants, inference of the target of a mutation or drug treatment and improving flux estimation.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] OLAV: Towards high-throughput tandem mass spectrometry data identification
    Colinge, J
    Masselot, A
    Giron, M
    Dessingy, T
    Magnin, J
    PROTEOMICS, 2003, 3 (08) : 1454 - 1463
  • [42] A reproducible approach to high-throughput biological data acquisition and integration
    Boernigen, Daniela
    Moon, Yo Sup
    Rahnavard, Gholamali
    Waldron, Levi
    McIver, Lauren
    Shafquat, Afrah
    Franzosa, Eric A.
    Miropolsky, Larissa
    Sweeney, Christopher
    Morgan, Xochitl C.
    Garrett, Wendy S.
    Huttenhower, Curtis
    PEERJ, 2015, 3
  • [43] Development of a High-Throughput Kinetics Protocol and Application to an Aza-Michael Reaction
    Li, Xiao
    Dunn, Anna L.
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2022, 26 (03) : 795 - 803
  • [44] Robust and Efficient Parametric Spectral Density Estimation for High-Throughput Data
    Lysy, Martin
    Zhu, Feiyu
    Yates, Bryan
    Labuda, Aleksander
    TECHNOMETRICS, 2022, 64 (01) : 30 - 51
  • [45] Genotype-Frequency Estimation from High-Throughput Sequencing Data
    Maruki, Takahiro
    Lynch, Michael
    GENETICS, 2015, 201 (02) : 473 - +
  • [46] Linkage Disequilibrium Estimation in Low Coverage High-Throughput Sequencing Data
    Bilton, Timothy P.
    McEwan, John C.
    Clarke, Shannon M.
    Brauning, Rudiger
    van Stijn, Tracey C.
    Rowe, Suzanne J.
    Dodds, Ken G.
    GENETICS, 2018, 209 (02) : 389 - 400
  • [47] Covariance Matrix Estimation for High-Throughput Biomedical Data with Interconnected Communities
    Yang, Yifan
    Chen, Chixiang
    Chen, Shuo
    AMERICAN STATISTICIAN, 2024, 78 (04): : 401 - 411
  • [48] High-throughput screening in heterogeneous reaction using chemical indicators
    Sun, B
    Meng, XJ
    Wang, SC
    Sun, SQ
    Xiao, FS
    CHINESE JOURNAL OF CATALYSIS, 2005, 26 (05) : 349 - 351
  • [49] Quantitative Modeling of the High-Throughput Production and In Vivo Kinetics of (Drug-Encapsulating) Liposomes
    Wong, Albert
    PLOS ONE, 2010, 5 (04):
  • [50] Processing of the spectrofluorimetric data using the graphical methods and the maximum likelihood approach
    Gamov, G. A.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 249