Patient radiation exposure during transcatheter aortic valve replacement procedures

被引:25
|
作者
Daneault, Benoit [1 ,2 ]
Balter, Stephen [1 ]
Kodali, Susheel K. [1 ,2 ]
Williams, Mathew R. [1 ,2 ]
Genereux, Philippe [1 ,2 ]
Reiss, George R. [1 ]
Paradis, Jean-Michel [1 ,2 ]
Green, Philip [1 ]
Kirtane, Ajay J. [1 ,2 ]
Smith, Craig [1 ,2 ]
Moses, Jeffrey W. [1 ]
Leon, Martin B. [1 ,2 ]
机构
[1] Columbia Univ, Med Ctr, New York Presbyterian Hosp, New York, NY 10032 USA
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
aortic stenosis; radiation; TAVR; GUIDED INTERVENTIONAL PROCEDURES; COREVALVE REVALVING SYSTEM; HIGH-RISK PATIENTS; IMPLANTATION; STENOSIS; OUTCOMES; REGISTRY; CARDIOLOGY; RADIOLOGY; SAFETY;
D O I
10.4244/EIJV8I6A106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To describe patient radiation utilisation during transcatheter aortic valve replacement (TAVR) on a series of consecutive patients. Methods and results: Data on radiation exposure were prospectively collected for consecutive patients undergoing TAVR and percutaneous coronary interventions at our centre. Radiation dose during the procedure was recorded using the US Food and Drug Administration (FDA) reference point (K-a,K-r) and the dose area product (P-KA). In addition to quantifying overall radiation doses during TAVR, radiation exposure during transfemoral (TF) (n=79) and transapical (TA) (n=26) cases was compared. The median radiation dose during TAVR was 1,639 mGy (983-2,420), or 188(106-321) Gy*cm(2). Radiation dose was significantly lower among TA patients using either the reference point (TA: 946 [777-1,261] vs. TF: 1,932 [1,383-2,614] mGy; p<0.001) or the dose area product (TA: 89 [60-115] vs. TF: 236 [164-338] Gy*cm(2); p<0.001). Fluoroscopy time was lower for TA patients (TA: 10 [8-11] vs. TF: 30 [24-34] minutes; p<0.001). Operators experience did not affect radiation exposure for TF cases. Conclusions: Radiation exposure during TAVR appears similar to other percutaneous coronary interventions of moderate complexity. Radiation doses were significantly lower for TA procedures. A higher dose of radiation in TF patients may be related to additional imaging requirements to optimise percutaneous vascular access and closure.
引用
收藏
页码:679 / 684
页数:6
相关论文
共 50 条
  • [1] Predictors of patient radiation exposure during transcatheter aortic valve replacement
    Goldsweig, Andrew M.
    Kennedy, Kevin F.
    Kolte, Dhaval
    Abbott, J. Dawn
    Gordon, Paul C.
    Sharaf, Barry L.
    Sellke, Frank W.
    Ehsan, Afshin
    Sodha, Neel R.
    Rutar, Frank
    Aronow, Herbert D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (04) : 768 - 774
  • [2] Minimizing Radiation Exposure during Transcatheter Aortic Valve Replacement (TAVR) Procedures
    Ramsewak, Adesh
    Sharma, Divyesh
    O'Conaire, Sean
    Verghis, R.
    Manoharan, Ganesh
    Spence, Mark
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B265 - B265
  • [3] PROVIDER RADIATION EXPOSURE DURING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Vishnevsky, Alec
    Savage, Rady Ho Michael
    Fischman, David
    Mehrotra, Praveen
    Entwhistle, John C., III
    Goldhammer, Jordan
    Marcantuono, Rebecca
    Moss, Lisa
    Keklak, John
    Davis, Marguerite
    Schmitz, Theresa
    Walinsky, Paul
    Morris, Rohinton
    Ruggiero, Nicholas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1030 - 1030
  • [4] Radiation Exposure During Transcatheter Aortic Valve Implantation (TAVI) Procedures
    Sharma, D.
    Ramsewak, A.
    O'Conaire, S.
    Spence, M.
    Manoharan, G.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2012, 181 : S321 - S322
  • [5] RADIATION EXPOSURE DURING TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) PROCEDURES
    Daneault, Benoit
    Balter, Stephen
    Kodali, Susheel
    Williams, Mathew
    Genereux, Philippe
    Hawkey, Marian
    Schnell, Susan
    Kirtane, Ajay
    Smith, Craig
    Moses, Jeffrey W.
    Leon, Martin B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1617 - E1617
  • [6] Operator Radiation Exposure During Transfemoral Transcatheter Aortic Valve Replacement
    Goel, Sunny
    Casazza, Richard
    Pasam, Ravi Teja
    Montagna, Enrico
    Gotesman, Joseph
    Frankel, Robert
    Borgen, Elliot
    Crooke, Gregory
    Saunders, Paul
    Shani, Jacob
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (01):
  • [7] RADIATION EXPOSURE REDUCTION DURING TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) PROCEDURES
    Sharma, D.
    Ramsewak, A.
    O'connaire, S.
    Verghis, R.
    Manoharan, G.
    Spence, M. S.
    HEART, 2013, 99 : A34 - A34
  • [8] Transcatheter Aortic Valve Replacement Operator Radiation Exposure (TAVORE)
    Casazza, Richard
    Goel, Sunny
    Shani, Jacob
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (04) : S55 - S55
  • [9] Cerebral Microembolic Exposure during Transcatheter Aortic Valve Replacement
    Tom, Stephanie
    Trivedi, Jaimin
    Flaherty, Michael
    Grubb, Kendra
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B268 - B268
  • [10] Radiation Exposure During Transcatheter Aortic Valve Replacement: Impact of Arterial Approach and Prosthesis Type
    Faroux, Laurent
    Villecourt, Aurelien
    Guimaraes, Leonardo
    Wintzer-Wehekind, Jerome
    Junquera, Lucia
    Arsenault, Jean
    Blanpain, Thierry
    Tassan-Mangina, Sophie
    Heroguelle, Virginie
    Ruggieri, Vito Giovanni
    Metz, Damien
    Kalavrouziotis, Dimitri
    Dumont, Eric
    Paradis, Jean-Michel
    Delarochelliere, Robert
    Del Val, David
    Muntane-Carol, Guillem
    Mohammadi, Siamak
    Rodes-Cabau, Josep
    ANNALS OF THORACIC SURGERY, 2021, 111 (05): : 1601 - 1606