Assessment of the influence of display veiling glare on observer and model performance

被引:0
|
作者
Krupinski, Elizabeth A. [1 ]
Lubin, Jeffrey [2 ]
Roehrig, Hans [1 ]
Johnson, Jeffrey [3 ]
Nafziger, John [3 ]
机构
[1] Univ Arizona, Dept Radiol, 1609 N Warren Ave, Tucson, AZ 85724 USA
[2] Sarnoff Corp, Princeton, NJ 80540 USA
[3] Siemens Corp Res, Princeton, NJ 80540 USA
关键词
veiling glare; physical characterization; observer performance;
D O I
10.1117/12.650677
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We evaluated human observer and model (JNDmetrix) performance to assess whether the veiling glare of a digital display influences performance in softcopy interpretation of mammographic images. 160 mammographic images, half with a single mass, were processed to simulate four levels of veiling glare: none, comparable to a typical cathode ray tube (CRT) display, double a CRT and quadruple a CRT. Six radiologist observers were shown the images in a randomized presentation order on a liquid crystal display (LCD) that had relatively no veiling glare. The JNDmetrix human visual system model also analyzed the images. Receiver Operating Characteristic (ROC) techniques showed that performance declined with increasing veiling glare (F = 6.884, p = 0.0035). Quadruple veiling glare yielded significantly lower performance than the lower veiling glare levels. The JNDmetrix model did not predict a reduction in performance with changes in veiling glare, and correlation with the human observer data was modest (0.588). Display veiling glare may influence observer performance, but only at very high levels.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Use of a human visual system model to predict the effects of display veiling glare on observer performance
    Krupinski, EA
    Johnson, J
    Roehrig, H
    Nafziger, J
    Fan, JH
    Lubin, J
    MEDICAL IMAGING 2004: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2004, 5372 : 423 - 429
  • [2] Method for measuring veiling glare in high-performance display devices
    Badano, A
    Flynn, MJ
    APPLIED OPTICS, 2000, 39 (13) : 2059 - 2066
  • [3] Method for measuring veiling glare in high-performance display devices
    Badano, A. (badano@umich.edu), 2000, Optical Society of America (OSA) (39):
  • [4] Using a human visual system model to optimize soft-copy mammography display: Influence of veiling glare
    Krupinski, EA
    Lubin, J
    Roehrig, H
    Johnson, J
    Nafziger, J
    ACADEMIC RADIOLOGY, 2006, 13 (03) : 289 - 295
  • [5] Correcting veiling glare of refined CIECAM02 for mobile display
    Park, YungKyung
    Luo, Ming Ronnier
    Li, Chang Jun
    Kwak, Youngshin
    Park, Du-Sik
    Kim, Changyeong
    COLOR RESEARCH AND APPLICATION, 2013, 38 (01): : 14 - 21
  • [6] Daytime veiling glare and driver visual performance: Influence of windshield rake angle and dashboard reflectance
    Schumann, J
    Flannagan, MJ
    Sivak, M
    Traube, EC
    JOURNAL OF SAFETY RESEARCH, 1997, 28 (03) : 133 - 146
  • [7] Full field mapping and analysis of veiling glare sources for Helmet Mounted Display systems
    Hasenauer, DM
    Kunick, JM
    CURRENT DEVELOPMENTS IN OPTICAL DESIGN AND OPTICAL ENGINEERING VIII, 1999, 3779 : 382 - 389
  • [8] Influence of the digital image display monitor on observer performance
    Cederberg, RA
    Frederiksen, NL
    Benson, BW
    Shulman, JD
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) : 203 - 207
  • [9] Discomfort Glare Model for Mobile Display
    Choe, Wonhee
    Lee, Min Woo
    2015 IEEE 5TH INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - BERLIN (ICCE-BERLIN), 2015, : 471 - 473
  • [10] An image-dependent model of veiling glare effects on detection performance in large-luminance-range displays
    Choi, Mina
    Albani, Luigi
    Badano, Aldo
    MEDICAL IMAGING 2012: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2012, 8318