Double-focusing ICP-MS for the analysis of biological materials

被引:8
|
作者
Marchante-Gayón, JM [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, Julian Claveria 8, E-33006 Oviedo, Spain
关键词
D O I
10.1007/s00216-004-2623-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The advantages and application of double-focusing (DF) inductively coupled plasma-mass spectrometry (ICP-MS) for the analysis of biological materials are described. The instrument combines a magnetic sector with an electrostatic sector and provides higher mass resolution by changing the widths and exist silts. The application of DF-ICP-MS to measure stable isotopes, which are used as tracers to study the absorption and matabolism of essential and toxic elements, is of great importance in biology and medicine. The ability for high-precision isotope ratio measurements afforded by DF-ICP-MS along with its extreme sensitivity at low resolution enables trace element speciation in biological materials.
引用
收藏
页码:335 / 337
页数:3
相关论文
共 50 条
  • [21] Strategies for isotope ratio measurements with a double focusing sector field ICP-MS
    M. Hamester
    D. Wiederin
    J. Wills
    W. Kerl
    C. B. Douthitt
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 495 - 498
  • [22] Strategies for isotope ratio measurements with a double focusing sector field ICP-MS
    Hamester, M
    Wiederin, D
    Wills, J
    Kerl, W
    Douthitt, CB
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05): : 495 - 497
  • [23] Isotopic and ultratrace analysis of uranium by double-focusing sector field ICP mass spectrometry
    W. Kerl
    J. S. Becker
    H.-J. Dietze
    W. Dannecker
    Fresenius' Journal of Analytical Chemistry, 1997, 359 : 407 - 409
  • [24] Isotopic and ultratrace analysis of uranium by double-focusing sector field ICP mass spectrometry
    Kerl, W
    Becker, JS
    Dietze, HJ
    Dannecker, W
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5): : 407 - 409
  • [25] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    García Alonso, J.I. (jiga@sauron.quimica.uniovi.es), 1600, Royal Society of Chemistry (18):
  • [26] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    Reyes, LH
    Gayón, JMM
    Alonso, JIG
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) : 11 - 16
  • [27] DOUBLE-FOCUSING DIODE
    TAKAGI, K
    APPLIED PHYSICS LETTERS, 1978, 33 (05) : 376 - 378
  • [28] Analytical Techniques Using ICP-MS for Clinical and Biological Analysis
    Ko, Jungaa
    Lim, H. B.
    MASS SPECTROMETRY LETTERS, 2015, 6 (04) : 85 - 90
  • [29] Total determination of essential and toxic elements in milk whey by double focusing ICP-MS
    Martino, FAR
    Sánchez, MLF
    Medel, AS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (02) : 163 - 168
  • [30] Determination of technetium-99, neptunium-237 and isotopes of thorium in uranyl nitrate solutions from a reprocessing plant, using double-focusing ICP-MS
    Mitterrand, Bernard
    Leprovost, Pierre
    Delaunay, Jacques
    Vian, Alain M.
    ASTM Special Technical Publication, 1999, (1344): : 64 - 75