Optimization of window type and vent parameters on single-sided natural ventilation buildings

被引:13
|
作者
Lenin, V. R. [1 ]
Sivalakshmi, S. [2 ]
Raja, M. [2 ]
机构
[1] Mahendra Inst Engn & Technol, Dept Mech Engn, Namakkal 637503, Tamil Nadu, India
[2] Govt Coll Engn, Dept Mech Engn, Salem 636011, Tamil Nadu, India
关键词
Buoyancy; Natural ventilation; Single-sided; Taguchi; Signal-to-noise ratio; ANOVA; THERMAL COMFORT; SIMULATION; DRIVEN; OPERATION; IMPACTS; ENERGY;
D O I
10.1007/s10973-018-7913-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
The residential building sector is one of the major areas to reduce energy demand. In this study, the single-sided top vent-based natural ventilation parameters are optimized using Taguchi technique. The computational fluid dynamics tool is used to simulate the room model. The grid sensitivity analysis is executed to predict more precise results. The operating parameters for top vent and window-based ventilation investigated are top vent width, top vent height, the location of the top vent, the number of top vents and window type with different levels. The orthogonal array, L-8, is selected for the conduct of experiments. The signal-to-noise ratio and analysis of variance technique are used to optimize the results. The optimized results showed that the maximum top vent width, top vent height and more number of vents with higher window opening area reduce the maximum indoor air temperature and increase the mass flow rate of a single-sided residential room. Of all, around 60.64% numbers of top vents contributed to indoor temperature reduction. In addition, thermal exergy is also investigated on various vent sectional planes.
引用
收藏
页码:367 / 379
页数:13
相关论文
共 50 条
  • [21] Full Numerical Investigations on the Wind Driven Natural Ventilation: Cross Ventilation and Single-sided Ventilation
    Ma, Xiao-Yu
    Peng, Yue
    Zhao, Fu-Yun
    Liu, Cheng-Wei
    Mei, Shuo-Jun
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3797 - 3803
  • [22] A computational study of single-sided ventilation
    Allocca, C
    Chen, QY
    Glicksman, LR
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 261 - 268
  • [23] Single-sided natural ventilation driven by wind pressure and temperature difference
    Larsen, Tine S.
    Heiselberg, Per
    ENERGY AND BUILDINGS, 2008, 40 (06) : 1031 - 1040
  • [24] EXPERIMENTAL INVESTIGATION ON SINGLE-SIDED TRANSIENT NATURAL VENTILATION DRIVEN BY BUOYANCY
    Vadugapalayam Rangasamy, Lenin
    Sivanathan, Sivalakshmi
    Muthu, Raja
    THERMAL SCIENCE, 2017, 21 : S489 - S496
  • [25] Experimental investigation on single-sided transient natural ventilation driven by buoyancy
    Vadugapalayam Rangasamy L.
    Sivanathan S.
    Muthu R.
    Vadugapalayam Rangasamy, Lenin (leninrangasamy@gmail.com), 2017, Serbian Society of Heat Transfer Engineers (21): : 489 - 496
  • [26] Analysis of Ventilation Efficiency and Effective Ventilation Flow Rate for Wind-driven Single-sided Ventilation Buildings
    Zhou, Junli
    Hua, Yong
    Xiao, Yuan
    Ye, Cheng
    Yang, Wei
    AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (05)
  • [27] Thermal Environment around Strong Heat Source with Single-Sided Natural Ventilation
    Liu, Dong
    Li, Siwei
    Miao, Qing
    ASHRAE TRANSACTIONS 2010, VOL 116, PT 1, 2010, 116 : 284 - 292
  • [28] Development of a new correlation for single-sided natural ventilation adapted to leeward conditions
    Caciolo, Marcello
    Cui, Shuqing
    Stabat, Pascal
    Marchio, Dominique
    ENERGY AND BUILDINGS, 2013, 60 : 372 - 382
  • [29] Effective depth of fresh air distribution in rooms with single-sided natural ventilation
    Gan, GH
    ENERGY AND BUILDINGS, 2000, 31 (01) : 65 - 73
  • [30] Impact of aperture separation on wind-driven single-sided natural ventilation
    Daish, N. C.
    da Graca, G. Carrilho
    Linden, P. F.
    Banks, D.
    BUILDING AND ENVIRONMENT, 2016, 108 : 122 - 134