Sophisticated Design of PVC Membrane Ion-Selective Electrodes Based on the Mixed Potential Theory

被引:4
|
作者
Imoto, Maya [1 ]
Sakaki, Toru [2 ]
Osakai, Toshiyuki [1 ]
机构
[1] Kobe Univ, Grad Sch Sci, Dept Chem, Nada Ku, Kobe, Hyogo 6578501, Japan
[2] A&T Corp, Fujisawa, Kanagawa 2520816, Japan
关键词
STANDARD GIBBS ENERGIES; INTERFACE; WATER; COEFFICIENTS;
D O I
10.1021/ac400427p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mixed potential (MP) theory was successfully utilized to design an ionophore-based polyvinyl chloride (PVC) membrane K+ ion-selective electrode (ISE). Prior to the application of the MP theory, the transfer of K+ and interfering ions (Na+, Li+, and H+) facilitated by bis(benzo-15-crown-5) (BB15C5) or dibenzo-18-crown-6 (DB18C6) at a micro PVC membrane/water interface was studied by ion-transfer voltammetry (ITV). The reversible half-wave potentials were then obtained for the facilitated transfer of the ions. Using such voltammetric data and the literature data about diffusion coefficients of ions, we could well-predict the potential responses of the BB15C5- or DB18C6-based K+ ISE, as the function of the concentrations of primary and interfering ions, and also of the counterion for K+ [e.g., tetrakis(4-chlorophenyl)borate] added to the membrane. Thus, the MP theory has been proven to be useful to optimize the membrane composition for a higher ion selectivity and a lower detection limit. It has also been found that the leaching of ions from an inner solution is too small to affect the detection limit, at least for the designed PVC membrane ISE.
引用
收藏
页码:4753 / 4760
页数:8
相关论文
共 50 条
  • [21] Response of PVC membrane ion-selective electrodes to alkylmethylimidazolium ionic liquid cations
    Zhuo, Kelei
    Wei, Yujing
    Ma, Jingjing
    Chen, Yujuan
    Bai, Guangyue
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 461 - 465
  • [22] Ion-selective membrane electrodes: Membrane configuration
    Stefan, RI
    AboulEnein, HY
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1997, 25 (02) : 169 - 173
  • [23] Papaverine PVC membrane ion-selective electrodes based on its ion-exchangers with tetraphenylborate and tetrathiocyanate anions
    Noor-Eldeen, Mohammed
    Mostafa, Gamal Abdel-Hafiz
    ANNALI DI CHIMICA, 2007, 97 (08) : 771 - 780
  • [24] Ion-selective membrane electrodes: Membrane configuration
    Univ of Bucharest, Bucharest, Romania
    Instrum Sci Technol, 2 (169-173):
  • [25] ION-SELECTIVE ELECTRODES WITH LIQUID MEMBRANE FOR CU(II) BASED ON SIMPLE AND MIXED COMPLEXES
    PLENICEANU, M
    MURESAN, N
    MURESAN, V
    LUCA, C
    REVISTA DE CHIMIE, 1992, 43 (5-6): : 282 - 286
  • [26] NI(II) ION-SELECTIVE ELECTRODES WITH LIQUID MEMBRANE, BASED ON SIMPLE AND MIXED COMPLEXES
    LUCA, C
    PLENICEANU, M
    MURESAN, N
    REVUE ROUMAINE DE CHIMIE, 1992, 37 (05) : 555 - 564
  • [27] ION-SELECTIVE MEMBRANE ELECTRODES - A REVIEW
    PUNGOR, E
    TOTH, K
    ANALYST, 1970, 95 (1132) : 625 - &
  • [28] THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
    Revenco, Mihail
    Martin, Mariana
    Abu Dayyih, Waell
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (01): : 73 - 77
  • [29] Study on the disposable urea biosensors based on PVC-COOH membrane ammonium ion-selective electrodes
    Chou, NH
    Chou, JC
    Sun, TP
    Hsiung, SK
    IEEE SENSORS JOURNAL, 2006, 6 (02) : 262 - 268
  • [30] The new theory of ion-selective electrodes
    Pungor, E
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 29 (02) : 111 - 120