Calculation of resonant modes for power supply systems and development of measures on higher harmonics filtering

被引:0
|
作者
Osipov, D. S. [1 ]
Kovalenko, D., V [1 ]
Eremin, E. N. [1 ]
Sidorov, O. A. [2 ]
Bigun, A. Ya [1 ]
机构
[1] Omsk State Tech Univ, 11 Mira Ave, Omsk 644050, Russia
[2] Omsk State Transport Univ, Omsk, Russia
关键词
DECISION;
D O I
10.1088/1742-6596/1260/5/052025
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the calculation of non-stationary non-sinusoidal mode of the power supply system (PSS) under the condition of current resonance (parallel resonance). Evaluation of the need for higher harmonics (HH) filtering was carried out. To achieve this, measurements of the actual level of HH and other unified power quality indexes were conducted, and oscillograms of the network mode parameters and HH spectrum were constructed. The measurement of unified power quality indexes was carried out with certified and calibrated power quality analyzers Metrel 2792A. These instruments satisfy the effective world standards on power quality and other reference documentation. Resonance frequencies where resonance modes emergence is possible were determined by calculation. Maximum overvoltage ratios for different points of the examined PSS were also determined.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Estimation, of higher order harmonics in electric power systems, and their compensation by situation control method
    Prokhorenkov, AM
    Remezovskiy, VM
    Sovlukov, AS
    IDAACS'2003: PROCEEDINGS OF THE SECOND IEEE INTERNATIONAL WORKSHOP ON INTELLIGENT DATA ACQUISITION AND ADVANCED COMPUTING SYSTEMS: TECHNOLOGY AND APPLICATIONS, 2003, : 335 - 338
  • [42] Description and Digital Calculation of Supply Reliability of Electric Power Systems.
    Bauer, Hartmut
    Czybik, Hans Peter
    Energietechnik Leipzig, 1980, 30 (01): : 2 - 7
  • [43] Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
    Blakiewicz, G.
    Jakusz, J.
    Jendernalik, W.
    Szczepanski, S.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2016, 64 (03) : 641 - 646
  • [44] Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
    Blakiewicz G.
    Jakusz J.
    Jendernalik W.
    Szczepański S.
    Blakiewicz, G. (blak@eti.pg.gda.pl), 1600, Polska Akademia Nauk (64): : 641 - 646
  • [45] Broadband robustly single-mode hollow-core PCF by resonant filtering of higher-order modes
    Uebel, Patrick
    Guenendi, Mehmet C.
    Frosz, Michael H.
    Ahmed, Goran
    Edavalath, Nitin N.
    Menard, Jean-Michel
    Russell, Philip St. J.
    OPTICS LETTERS, 2016, 41 (09) : 1961 - 1964
  • [46] Development and Evaluation of an Isolated Resonant Converter for Auxiliary Power Supply in DC Traction
    Bhajana, Veera Venkata Subrahmanya Kumar
    Drabek, Pavel
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2019, 9 (02) : 4048 - 4052
  • [47] Development of medical ruby laser power supply using LLC resonant converter
    Kim, H.-J. (heeje@pusan.ac.kr), 1600, Korean Institute of Electrical Engineers (63):
  • [48] Development of Underwater Wireless Power Supply System Using Resonant Energy Transfer
    Hidaka, Shota
    Ishii, Kazuo
    Watanabe, Keisuke
    ICAROB 2017: PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS, 2017, : P258 - P261
  • [49] Development of a Power Supply Vehicle for Safe and Secure Renewal of Power Supply Equipment for Access Systems
    Fujimoto, Tomio
    Tanaka, Toru
    Serada, Takuji
    32ND INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2010,
  • [50] INFLUENCE OF THYRISTOR-CONTROLLED REACTORS ON HARMONICS AND RESONANCE EFFECTS IN POWER-SUPPLY SYSTEMS
    WESCHTA, A
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1985, 14 (02): : 62 - 68