The origin of double peak electric field distribution in heavily irradiated silicon detectors

被引:100
|
作者
Eremin, V
Verbitskaya, E
Li, Z
机构
[1] Russian Acad Sci, AF Ioffe Physicotech Inst, St Petersburg 194021, Russia
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
D O I
10.1016/S0168-9002(01)01642-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The first observation of double peak (DP) electric field distribution in heavily neutron irradiated (> 10(14) n/cm(2)) semiconductor detectors has been published about 6 yr ago. However, this effect was not quantitatively analyzed up to now. The explanation of the DP electric field distribution presented in this paper is based on the properties of radiation induced deep levels in silicon, which act as deep traps, and on the distribution of the thermally generated free carrier concentration in the detector bulk. In the frame of this model, the earlier published considerations on the so-called "double junction (DJ) effect" are discussed as well. The comparison of the calculated electric field profiles at different temperatures with the experimental ones allows one to determine a set of deep levels. This set of deep levels, and their charge filling status are essential to the value and the distribution of space charge in the space charge region in the range of 305-240 K, which is actual temperature range for the main experiments at LHC where silicon detectors are used. This set of deep levels includes the levels located close to the midgap and does not contain the defects with the largest introduction rate -(C-i-O-i ) and (V-V). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 50 条
  • [1] Double peak electric field distortion in heavily irradiated silicon strip detectors
    Eremin, V
    Li, Z
    Roe, S
    Ruggiero, G
    Verbitskaya, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (03): : 622 - 631
  • [2] Electric field distribution in irradiated silicon detectors
    Castaldini, A
    Cavallini, A
    Polenta, L
    Nava, F
    Canali, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03): : 550 - 555
  • [3] Concept of Double Peak electric field distribution in the development of radiation hard silicon detectors
    Verbitskaya, E.
    Eremin, V.
    Li, Z.
    Haerkoenen, J.
    Bruzzi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (01): : 77 - 86
  • [4] The electric field in irradiated silicon detectors
    Beattie, LJ
    Brodbeck, TJ
    Chilingarov, A
    Hughes, G
    McGarry, SA
    Ratof'f, PN
    Sloan, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 314 - 321
  • [5] Extraction of electric field in heavily irradiated silicon pixel sensors
    Dorokhov, A
    Allkofer, Y
    Amsler, C
    Bortoletto, D
    Chiochia, V
    Cremaldi, L
    Cucciarelli, S
    Hörmann, C
    Kim, D
    Konecki, M
    Kotlinski, D
    Prokofiev, K
    Regenfus, C
    Rohe, T
    Sanders, D
    Son, S
    Speer, T
    Swartz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (01): : 112 - 117
  • [6] Test results on heavily irradiated silicon detectors
    Borrello, L
    Bozzi, C
    Dell'Orso, R
    Dutta, S
    Messineo, A
    Rizzo, F
    Starodumov, A
    Tonelli, G
    Verdini, PG
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (11): : 1285 - 1291
  • [7] Cryogenic temperature performance of heavily irradiated silicon detectors
    da Via, C
    Bell, WH
    Casagrande, L
    Granata, V
    Palmieri, VG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01): : 114 - 117
  • [8] Operation of heavily irradiated silicon detectors under forward bias
    Chilingarov, A
    Sloan, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (01): : 35 - 37
  • [9] A two-level model for heavily irradiated silicon detectors
    Borchi, E
    Bruzzi, M
    Li, Z
    Pirollo, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2): : 343 - 346
  • [10] TSC DATA-ANALYSIS ON HEAVILY IRRADIATED SILICON DETECTORS
    BRUZZI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03): : 618 - 621