Microtensile bond strength of current dentin adhesives measured immediately and 24 hours after application

被引:0
|
作者
Sadek, FT
Goracci, C
Cardoso, PEC
Tay, FR
Ferrari, M
机构
[1] Univ Sao Paulo, Dept Dent Mat, Sao Paulo, Brazil
[2] Univ Siena, Dept Dent Mat, I-53100 Siena, Italy
[3] Univ Sao Paulo, Sao Paulo, Brazil
[4] Univ Hong Kong, Hong Kong, Hong Kong, Peoples R China
来源
JOURNAL OF ADHESIVE DENTISTRY | 2005年 / 7卷 / 04期
关键词
microtensile bond strength; dentin; adhesive system; test period;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the immediate microtensile bond strengths achieved with representative adhesive systems from each of the four current bonding approaches. Materials and Methods: Resin composite was bonded incrementally to flat, midcoronal dentin from 33 human molars, using the adhesives (Adper Scotchbond MP; Adper Scotchbond 1; Optibond Solo Plus; Clearfil SE Bond; AdheSE; Tyrian SPE + One Step Plus; Optibond Solo Plus self-etching; One-Up Bond F; iBond; Adper Prompt L-Pop; Xeno III) according to the respective manufacturer's instructions. The bonded specimens were immediately sectioned into sticks and underwent microtensile bond testing either immediately or after 24 h. Data were analyzed with two-way ANOVA and LSD tests. Results: No significant differences were found between immediate and 24-h bond strengths (p > 0.05). However, significant differences were observed among adhesives (p = 0.001). The all-in-one adhesive iBond showed statistically lower values when compared to all the other adhesives. Adper Prompt L-Pop, Xeno III, Tyrian SPE + One Step Plus and One-Up Bond F, all self-etching adhesives, were significantly weaker than AdheSE, Optibond Solo Plus, Adper Scotchbond 1, Optibond Solo Plus self-etching, Clearfil SE Bond, and Adper Scotchbond MP, which did not differ statistically from each other. Conclusion: Microtensile bond strengths of representative adhesive systems from the four categories of bonding agents were not equivalent, with the lowest values recorded for the one-step self-etching adhesives. There were no differences in the bond strengths when measured immediately and after 24 h.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [21] Influence of Er,Cr:YSGG laser treatment on the microtensile bond strength of adhesives to dentin
    Cardoso, Marcio Vivan
    Coutinho, Eduardo
    Ermis, R. Banu
    Poitevin, Andre
    Van Landuyt, Kirsten
    De Munck, Jan
    Carvalho, Rubens C. R.
    Lambrechts, Paul
    Van Meerbeek, Bart
    JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (01): : 25 - 33
  • [22] Microtensile bond strength and confocal microscopy of dental adhesives bonded to root canal dentin
    Mannocci, F
    Sherriff, M
    Ferrari, M
    Watson, TF
    AMERICAN JOURNAL OF DENTISTRY, 2001, 14 (04): : 200 - 204
  • [23] Comparative Evaluation of Microtensile Dentin Bond Strength and Interfacial Micromorphology of Three Universal Adhesives
    Fathy, Yassmine
    ElKholany, Naglaa R.
    Abdallah, Asmaa M.
    Zaghloul, Nadia M.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2024, 32 (03): : 335 - 345
  • [24] Effect of Nd:YAG laser irradiation on microtensile bond strength of universal adhesives to dentin
    Jafarnia, Shiva
    Zeinaddini Meymand, Javad
    Zandkarimi, Fateme
    Saberi, Sogol
    Valanezhad, Alireza
    Shahabi, Sima
    LASER PHYSICS, 2021, 31 (05)
  • [25] Microtensile bond strength to dentin of different self-etching adhesives after 12 months' storage.
    Osorio, R.
    Osorio, E.
    Toledano, M.
    Aguilera, F. S.
    Garcia-Godoy, F., Sr.
    Tay, F. R.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B55 - B55
  • [26] Primer application technique and remaining dentin thickness affected microtensile bond strength of contemporary dentin adhesives under simulated pulp pressure
    Somrit, Paphawee
    Tantilertanant, Yanee
    Srisawasdi, Sirivimol
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (01) : 139 - 149
  • [27] Primer application technique and remaining dentin thickness affected microtensile bond strength of contemporary dentin adhesives under simulated pulp pressure
    Paphawee Somrit
    Yanee Tantilertanant
    Sirivimol Srisawasdi
    Clinical Oral Investigations, 2023, 27 : 139 - 149
  • [28] Effect of Ozone Application on the Resin-dentin Microtensile Bond Strength
    Rodrigues, P. C. F.
    Souza, J. B.
    Soares, C. J.
    Lopes, L. G.
    Estrela, C.
    OPERATIVE DENTISTRY, 2011, 36 (05) : 537 - 544
  • [29] Effect of exposure time of zinc oxide eugenol restoration on microtensile bond strength of adhesives to dentin
    Pinto, Karinne Trauassos
    Stanislawczuk, Rodrigo
    Loguercio, Alessandro Dourado
    Miranda Grande, Rosa Helena
    Bauer, Jose
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2014, 55 (02): : 83 - 88
  • [30] Microtensile bond strength to primary dentin after chemomechanical caries removal
    Frankenberger, R
    Oberschachtsiek, H
    Krämer, N
    Petschelt, A
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 372 - 372