Exploring the effect of sintering temperature on naturally derived hydroxyapatite for bio-medical applications

被引:23
|
作者
Aarthy, S. [1 ]
Thenmuhil, D. [1 ]
Dharunya, G. [2 ]
Manohar, P. [1 ]
机构
[1] Anna Univ, Alagapa Coll Technol, Dept Ceram Technol, Chennai 600025, TN, India
[2] Cent Leather Res Inst, CSIR, Biomat Dept, Chennai 600020, TN, India
关键词
BONES; BEHAVIOR; SCAFFOLD; MATRIX;
D O I
10.1007/s10856-019-6219-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The current work describes the influence of sintering temperatures on biological and mechanical properties of naturally derived hydroxyapatite (HAp). The phase pure hydroxyapatite developed from the goat bone has been obtained by optimizing the calcination temperature from 600-900 degrees C. Further, HAp calcined at 900 degrees C was subjected to various sintering temperature (1100-1400 degrees C). Finally, the influence of sinter temperatures on mechanical (hardness) and biological properties (in vitro bioactivity, MTT and hemocompatibility assays) were ascertained. In respect of biological properties, it came to know that 1300 degrees C is optimum sinter temperature, which has enhanced apatite growth with the superior cell viability and hemo-compatible behavior. However, sample sintered at 1400 degrees C delivers maximum hardness. Thus, the hydroxyapatite extracted from goat bone can find better applications in bio-medical engineering as analogous to the existing man-made synthetic materials. [GRAPHICS] .
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [21] Advanced Electromagnetic Field Solvers for Bio-Medical Applications
    Gao, J.
    Munteanu, I.
    Strydom, M.
    Weiland, T.
    Wittig, T.
    2012 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2012, : 23 - 26
  • [22] Rectennas Performance based on Substrates for Bio-medical Applications
    Yoon, Hargsoon
    Williams, Frances
    Song, Kyo D.
    Yang, Sang Y.
    Kim, Jae Hwan
    Lee, Kunsik
    Choi, Sang H.
    NANOSENSORS, BIOSENSORS, AND INFO-TECH SENSORS AND SYSTEMS 2010, 2010, 7646
  • [23] Mössbauer Absorption Spectroscopy: Bio-medical applications
    S. Croci
    I. Ortalli
    La Rivista del Nuovo Cimento, 2011, 34 : 69 - 101
  • [24] Copper Chelators: Chemical Properties and Bio-medical Applications
    Tegoni, M.
    Valensin, D.
    Toso, L.
    Remelli, M.
    CURRENT MEDICINAL CHEMISTRY, 2014, 21 (33) : 3785 - 3818
  • [25] Implantable CMOS Imaging Devices for Bio-Medical Applications
    Ohta, Jun
    2011 IEEE 54TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2011,
  • [26] Advances in Carbon Based Nanomaterials for Bio-Medical Applications
    Gupta, Tejendra Kumar
    Budarapu, Pattabhi Ramaiah
    Chappidi, Sivakumar Reddy
    Sastry, Sudhir Y. B.
    Paggi, Marco
    Bordas, Stephane P.
    CURRENT MEDICINAL CHEMISTRY, 2019, 26 (38) : 6851 - 6877
  • [27] ACCELERATOR MASS-SPECTROMETRY IN THE BIO-MEDICAL SCIENCES - APPLICATIONS IN LOW-EXPOSURE BIO-MEDICAL AND ENVIRONMENTAL DOSIMETRY
    FELTON, JS
    TURTELTAUB, KW
    VOGEL, JS
    BALHORN, R
    GLEDHILL, BL
    SOUTHON, JR
    CAFFEE, MW
    FINKEL, RC
    NELSON, DE
    PROCTOR, ID
    DAVIS, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 52 (3-4): : 517 - 523
  • [28] Shape Memory Materials for Bio-medical and Aerospace Applications
    Dhanasekaran, R.
    Reddy, Sreenatha S.
    Kumar, Girish B.
    Anirudh, A. S.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (10) : 21427 - 21435
  • [29] Charge and Current Measuring Electronics for Bio-Medical Applications
    Carminati M.
    IEEE Instrumentation and Measurement Magazine, 2022, 25 (04): : 29 - 35
  • [30] FILM CIRCUIT OPERATIONAL AMPLIFIERS AND THEIR BIO-MEDICAL APPLICATIONS
    GELDARD, NR
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (04): : 669 - &