Distinguishing the causes of falls in humans using an array of wearable tri-axial accelerometers

被引:46
|
作者
Aziz, Omar [1 ,3 ]
Park, Edward J. [3 ]
Mori, Greg [4 ]
Robinovitch, Stephen N. [1 ,2 ,3 ]
机构
[1] Simon Fraser Univ, Injury Prevent & Mobil Lab, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Dept Biomed Physiol & Kinesiol, Burnaby, BC V5A 1S6, Canada
[3] Simon Fraser Univ, Sch Engn Sci, Burnaby, BC V5A 1S6, Canada
[4] Simon Fraser Univ, Sch Comp Sci, Burnaby, BC V5A 1S6, Canada
基金
加拿大健康研究院;
关键词
Wearable sensors (accelerometers); Accidental falls (prevention and control); Posture and balance; Machine learning; ELDERLY-PEOPLE; ACCURACY; IMPACT; HOME;
D O I
10.1016/j.gaitpost.2013.08.034
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Falls are the number one cause of injury in older adults. Lack of objective evidence on the cause and circumstances of falls is often a barrier to effective prevention strategies. Previous studies have established the ability of wearable miniature inertial sensors (accelerometers and gyroscopes) to automatically detect falls, for the purpose of delivering medical assistance. In the current study, we extend the applications of this technology, by developing and evaluating the accuracy of wearable sensor systems for determining the cause of falls. Twelve young adults participated in experimental trials involving falls due to seven causes: slips, trips, fainting, and incorrect shifting/transfer of body weight while sitting down, standing up from sitting, reaching and turning. Features (means and variances) of acceleration data acquired from four tri-axial accelerometers during the falling trials were input to a linear discriminant analysis technique. Data from an array of three sensors (left ankle + right ankle + sternum) provided at least 83% sensitivity and 89% specificity in classifying falls due to slips, trips, and incorrect shift of body weight during sitting, reaching and turning. Classification of falls due to fainting and incorrect shift during rising was less successful across all sensor combinations. Furthermore, similar classification accuracy was observed with data from wearable sensors and a video-based motion analysis system. These results establish a basis for the development of sensor-based fall monitoring systems that provide information on the cause and circumstances of falls, to direct fall prevention strategies at a patient or population level. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 50 条
  • [1] Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test
    Doheny, Emer P.
    Walsh, Cathal
    Foran, Timothy
    Greene, Barry R.
    Fan, Chie Wei
    Cunningham, Clodagh
    Kenny, Rose Anne
    [J]. GAIT & POSTURE, 2013, 38 (04) : 1021 - 1025
  • [2] Using tri-axial accelerometers to remotely identify ursid behavior
    Pagano, A. M.
    Rode, K. D.
    Cutting, A.
    Owen, M. A.
    Jensen, S.
    Ware, J., V
    Robbins, C. T.
    Durner, G. M.
    Williams, T. M.
    [J]. INTEGRATIVE AND COMPARATIVE BIOLOGY, 2016, 56 : E346 - E346
  • [3] Effective detection method for falls according to the distance between two tri-axial accelerometers
    Jae-Hyung Kim
    Geun-Chul Park
    Soo-Hong Kim
    Soo-Sung Kim
    Hae-Rim Lee
    Gye-Rok Jeon
    [J]. Journal of the Korean Physical Society, 2016, 68 : 914 - 922
  • [4] Effective detection method for falls according to the distance between two tri-axial accelerometers
    Kim, Jae-Hyung
    Park, Geun-Chul
    Kim, Soo-Hong
    Kim, Soo-Sung
    Lee, Hae-Rim
    Jeon, Gye-Rok
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (07) : 914 - 922
  • [5] Modeling of Tri-axial Accelerometers in a Self-designed Wearable Inertial Measurement Unit
    Alqudah, Hamzah
    Cui, Xiwei
    Ye, Lin
    Cao, Kai
    Szymanski, Jan
    Guo, Ying
    Su, Steven
    [J]. 2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 605 - 610
  • [6] Study on calibration method for tri-axial accelerometers
    Lv, Caiping
    Chen, Xiyuan
    Huang, Haoqian
    Zhou, Zhikai
    [J]. 2015 2ND IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (METROAEROSPACE), 2015, : 15 - 20
  • [7] RAIL DEFECT DETECTION USING DATA FROM TRI-AXIAL ACCELEROMETERS
    Abuhamdia, Tariq
    Taheri, Saied
    Meddah, Abe
    Davis, David
    [J]. PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2014, 2014,
  • [8] Significant Features for Human Activity Recognition Using Tri-Axial Accelerometers
    Bennasar, Mohamed
    Price, Blaine A.
    Gooch, Daniel
    Bandara, Arosha K.
    Nuseibeh, Bashar
    [J]. SENSORS, 2022, 22 (19)
  • [9] Using tri-axial accelerometers to identify wild polar bear behaviors
    Pagano, A. M.
    Rode, K. D.
    Cutting, A.
    Owen, M. A.
    Jensen, S.
    Ware, J. V.
    Robbins, C. T.
    Durner, G. M.
    Atwood, T. C.
    Obbard, M. E.
    Middel, K. R.
    Thiemann, G. W.
    Williams, T. M.
    [J]. ENDANGERED SPECIES RESEARCH, 2017, 32 : 19 - 33
  • [10] High Precision Tri-Axial Quartz Flexible Accelerometers Resolution Measurement Method Based on Tri-Axial Turntable
    Zhang, Chunxi
    Dai, Minpeng
    Luo, Wei
    Pan, Xiong
    [J]. IEEE ACCESS, 2020, 8 : 53463 - 53470