Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test

被引:81
|
作者
Doheny, Emer P. [1 ]
Walsh, Cathal [2 ]
Foran, Timothy [3 ]
Greene, Barry R. [1 ]
Fan, Chie Wei [4 ]
Cunningham, Clodagh
Kenny, Rose Anne [4 ]
机构
[1] Intel Corp, Intel Labs, Hlth Res & Innovat, Leixlip, Kildare, Ireland
[2] Univ Dublin Trinity Coll, Dept Stat, Dublin 2, Ireland
[3] St James Hosp, Dept Med Phys & Clin Engn, Dublin 8, Ireland
[4] St James Hosp, Dept Med Gerontol, Dublin 8, Ireland
关键词
Accelerometer; Logistic regression; Falls risk assessment; Postural transitions; Classifier; TO-STAND MOVEMENT; RECURRENT FALLS; OLDER-PEOPLE; RISK-FACTORS; GO TEST; AGED; 65; SIT; COMMUNITY; BALANCE; PERFORMANCE;
D O I
10.1016/j.gaitpost.2013.05.013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The five-times-sit-to-stand test (FTSS) is an established assessment of lower limb strength, balance dysfunction and falls risk. Clinically, the time taken to complete the task is recorded with longer times indicating increased falls risk. Quantifying the movement using tri-axial accelerometers may provide a more objective and potentially more accurate falls risk estimate. 39 older adults, 19 with a history of falls, performed four repetitions of the FTSS in their homes. A tri-axial accelerometer was attached to the lateral thigh and used to identify each sit-stand-sit phase and sit-stand and stand-sit transitions. A second tri-axial accelerometer, attached to the sternum, captured torso acceleration. The mean and variation of the root-mean-squared amplitude, jerk and spectral edge frequency of the acceleration during each section of the assessment were examined. The test-retest reliability of each feature was examined using intra-class correlation analysis, ICC(2,k). A model was developed to classify participants according to falls status. Only features with ICC > 0.7 were considered during feature selection. Sequential forward feature selection within leave-one-out cross-validation resulted in a model including four reliable accelerometer-derived features, providing 74.4% classification accuracy, 80.0% specificity and 68.7% sensitivity. An alternative model using FTSS time alone resulted in significantly reduced classification performance. Results suggest that the described methodology could provide a robust and accurate falls risk assessment. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1021 / 1025
页数:5
相关论文
共 50 条
  • [1] Interrater Reliability of the Five-Times-Sit-to-Stand Test
    Wallmann, Harvey W.
    Evans, Nicole S.
    Day, Christopher
    Neelly, Kurt R.
    [J]. HOME HEALTH CARE MANAGEMENT AND PRACTICE, 2013, 25 (01): : 13 - 17
  • [2] IS THE FIVE-TIMES-SIT-TO-STAND TEST A MEASURE OF BALANCE OR STRENGTH IN OLDER ADULTS?
    Goldberg, A.
    Talley, S.
    [J]. GERONTOLOGIST, 2012, 52 : 200 - 200
  • [3] The repetitive Five-Times-Sit-To-Stand test: its reliability in older adults
    Teo, Tilda W. L.
    Mong, Yiqin
    Ng, Shamay S. M.
    [J]. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2013, 20 (03): : 122 - 130
  • [4] The five-times-sit-to-stand test: validity, reliability and detectable change in older females
    Goldberg, Allon
    Chavis, Martina
    Watkins, Johnny
    Wilson, Tyler
    [J]. AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2012, 24 (04) : 339 - 344
  • [5] The five-times-sit-to-stand test: validity, reliability and detectable change in older females
    Allon Goldberg
    Martina Chavis
    Johnny Watkins
    Tyler Wilson
    [J]. Aging Clinical and Experimental Research, 2012, 24 (4) : 339 - 344
  • [6] Five-times-sit-to-stand test in children with cerebral palsy: Reliability and concurrent validity
    Kumban, Wannisa
    Amatachaya, Sugalya
    Emasithi, Alongkot
    Siritaratiwat, Wantana
    [J]. NEUROREHABILITATION, 2013, 32 (01) : 9 - 15
  • [7] Distinguishing the causes of falls in humans using an array of wearable tri-axial accelerometers
    Aziz, Omar
    Park, Edward J.
    Mori, Greg
    Robinovitch, Stephen N.
    [J]. GAIT & POSTURE, 2014, 39 (01) : 506 - 512
  • [8] Clinical measurement of sit-to-stand performance in people with balance disorders: Validity of data for the five-times-sit-to-stand test
    Whitney, SL
    Wrisley, DM
    Marchetti, GF
    Gee, MA
    Redfern, MS
    Furman, JM
    [J]. PHYSICAL THERAPY, 2005, 85 (10): : 1034 - 1045
  • [9] Assessing head and trunk symmetry during sleep using tri-axial accelerometers
    Sato, Haruhiko
    Ikura, Daiki
    Tsunoda, Masahiro
    [J]. DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2015, 10 (02) : 113 - 117
  • [10] Validity and reliability of five-times-sit-to-stand test with a dual task in older adults with mild cognitive impairment
    Chimsuwan, Perayut
    Chanabangkaew, Kanyakon
    Aniwattanapong, Daruj
    Suriyaamarit, Duangporn
    [J]. PHYSIOTHERAPY PRACTICE AND RESEARCH, 2023, 44 (01) : 63 - 68