Low dose measurements in a routine personal dosimetry service

被引:8
|
作者
Bonamini, D [1 ]
机构
[1] Tecnorad, I-37135 Verona, Italy
关键词
D O I
10.1093/oxfordjournals.rpd.a032814
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Tecnorad set up a complete series of tests for both TLD and film dosimetry to verify the ability of its dosimetry service to meet the requirements stated in ICRP 60 and in the Italian Legislative Decree 230/95 of 1 mSv.y(-1) for the public and for persons not exposed to radiation in their workplace. The service uses GR-200A LiF:Mg,Cu,P TLDs and Kodak Type 2 film dosemeters packed in proprietary badges. The measurements of low doses, comparable with the background value, have been carried out during several wearing periods in the past year (1997) the results of which are presented. Values of L-D (detection limit) less than 20 mu Sv (TLD system) and less than 80 mu Sv (film dosemeter system) have been determined. The requirement of a personal dosimetry system able to measure down to 80 mu Sv per month, also with high energy photon radiations, is fulfilled for both TLD and film methods.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 50 条
  • [21] IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry
    Izewska, J
    Bera, P
    Vatnitsky, S
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A387 - A392
  • [22] A comparison of personal dose equivalent measurements made by personal dosemeters
    Cechak, T.
    Davidkova, J.
    Kodl, O.
    Novacek, P.
    Papirnik, P.
    Petrova, K.
    Prasek, P.
    Martincik, J.
    Sochor, V.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 48 - 50
  • [23] Gel dosimetry technique for measurements in high dose gradients
    Heard, M
    Ibbott, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1888 - 1888
  • [24] THERMOLUMINESCENCE DOSIMETRY IN CLINICAL RADIATION-DOSE MEASUREMENTS
    TARAKANATH, MS
    NOVOTNY, J
    STRAHLENTHERAPIE, 1976, 152 (01) : 71 - 77
  • [25] FIELD MEASUREMENTS, ABSORBED DOSE, AND BIOLOGIC DOSIMETRY OF MICROWAVES
    PHILLIPS, RD
    HUNT, EL
    KING, NW
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1975, 247 (FEB28) : 499 - 509
  • [26] An Italian InterLaboratory comparison on personal dose equivalent for dosimetry services: promoting measurements reliability and addressing new digital challenges
    Iafrati, Anna Cristina
    Cappadozzi, Gianluca
    Silvestri, Claudia
    Pinto, Massimo
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (03):
  • [27] An Italian InterLaboratory comparison on personal dose equivalent for dosimetry services: promoting measurements reliability and addressing new digital challenges
    Anna Cristina Iafrati
    Gianluca Cappadozzi
    Claudia Silvestri
    Massimo Pinto
    The European Physical Journal Plus, 139
  • [28] FILM DOSIMETRY - LINEARIZATION OF DOSE-RESPONSE FOR RELATIVE MEASUREMENTS OF DOSE DISTRIBUTION
    MOTA, HC
    SIBATA, CH
    ROBERTS, W
    HIGGINS, PD
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04): : 565 - 569
  • [29] A ROUTINE LOW-LEVEL THERMOLUMINESCENT PERSONNEL DOSIMETRY SYSTEM
    JOHNSON, RG
    HOECKER, FE
    HEALTH PHYSICS, 1968, 15 (02): : 177 - +
  • [30] Applicability of the Dose Spiking Electron Paramagnetic Resonance Method for the Quantitative Measurements of Low Doses in Alanine Dosimetry
    Ghimire, Lekhnath
    Waller, Edward