Low dose measurements in a routine personal dosimetry service

被引:8
|
作者
Bonamini, D [1 ]
机构
[1] Tecnorad, I-37135 Verona, Italy
关键词
D O I
10.1093/oxfordjournals.rpd.a032814
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Tecnorad set up a complete series of tests for both TLD and film dosimetry to verify the ability of its dosimetry service to meet the requirements stated in ICRP 60 and in the Italian Legislative Decree 230/95 of 1 mSv.y(-1) for the public and for persons not exposed to radiation in their workplace. The service uses GR-200A LiF:Mg,Cu,P TLDs and Kodak Type 2 film dosemeters packed in proprietary badges. The measurements of low doses, comparable with the background value, have been carried out during several wearing periods in the past year (1997) the results of which are presented. Values of L-D (detection limit) less than 20 mu Sv (TLD system) and less than 80 mu Sv (film dosemeter system) have been determined. The requirement of a personal dosimetry system able to measure down to 80 mu Sv per month, also with high energy photon radiations, is fulfilled for both TLD and film methods.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 50 条
  • [1] Correlation Between Routine Personal Dosimetry Reading and the Dose to the Brain of Interventional Staff
    Smeulders, Jelle
    da Silva, Edilaine Honorio
    Struelens, Lara
    Vanhavere, Filip
    De Mey, Johan
    Martin, Colin J.
    Buls, Nico
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 349 - 357
  • [2] Low dose personal dosimetry using commercial LiF detectors
    Uray, I
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 53 - 56
  • [3] Glow curve evaluation in routine personal dosimetry
    Al-Haj, AN
    Lagarde, CS
    HEALTH PHYSICS, 2004, 86 (02): : S15 - S19
  • [4] DOSE EQUIVALENT INDEX AND PERSONAL DOSIMETRY
    JOHNS, TF
    HEALTH PHYSICS, 1980, 39 (01): : 92 - 95
  • [5] DOSE ALGORITHMS FOR PERSONAL THERMOLUMINESCENCE DOSIMETRY
    MOSCOVITCH, M
    RADIATION PROTECTION DOSIMETRY, 1993, 47 (1-4) : 373 - 380
  • [6] The ENEA neutron personal dosimetry service
    Morelli, B.
    Mariotti, F.
    Fantuzzi, E.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 312 - 315
  • [7] THE METHOD FOR THE PENETRATING AND SUPERFICIAL DOSE EQUIVALENTS EVALUATION IN THE CZECHOSLOVAK NATIONAL PERSONAL DOSIMETRY SERVICE
    STAROSTOVA, V
    TROUSIL, J
    KOTEN, J
    PROUZA, Z
    KERNENERGIE, 1989, 32 (01): : 4 - 8
  • [8] Intercomparison of Personal Dosimetry for Service Providers in Pakistan
    Jabeen, Akhter
    Salman, Syed Ahmad
    HEALTH PHYSICS, 2009, 96 (02): : S5 - S10
  • [9] THE NRPB PADC NEUTRON PERSONAL DOSIMETRY SERVICE
    GILVIN, PJ
    BARTLETT, DT
    STEELE, JD
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 99 - 102
  • [10] The NRPB PADC neutron personal dosimetry service
    Gilvin, PJ
    Bartlett, DT
    Shaw, PV
    Steele, JD
    Tanner, RJ