I-gel insertion by novices in manikins and patients

被引:84
|
作者
Wharton, N. M. [1 ]
Gibbison, B.
Gabbott, D. A. [2 ]
Haslam, G. M. [2 ]
Muchatuta, N.
Cook, T. M. [1 ]
机构
[1] Royal United Hosp, Bath BA1 3NG, Avon, England
[2] Gloucestershire Royal Hosp, Gloucester GL1 3NN, England
关键词
D O I
10.1111/j.1365-2044.2008.05542.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The i-gel, a novel supraglottic airway, has been proposed for use during cardiopulmonary resuscitation. We evaluated the performance of this device in manikins and anaesthetised patients when used by novices: medical students, non-anaesthetist physicians and allied health professionals all unfamiliar with the i-gel. Fifty i-gels were placed in manikins. Eighty-eight percent (44/50) were placed on the first attempt with a median insertion time of 14 s (range 7-45). I-gels were placed in 40 healthy anaesthetised patients. Success on the first attempt was 82.5% (33/40) and on the second attempt 15% (6/40). After three attempts there were no failures. Median insertion time was 17.5 s (range 7-197). Median airway seal was 20 cmH(2)O (range 13-40). One case of regurgitation and partial aspiration occurred. Our results suggest the i-gel is rapidly inserted in both manikins and patients by novice users and compares favourably to other supraglottic airways available. Further work determining safety and efficacy during cardiopulmonary resuscitation is required.
引用
收藏
页码:991 / 995
页数:5
相关论文
共 50 条
  • [21] Effect of Nebulised Lignocaine on the Quality of I-gel Insertion: A Randomised Controlled Trial
    Sannaboraiah, Sushma K.
    Pushpavathi, H. S.
    Yashaswini, K. L.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : UC5 - UC9
  • [22] Modified jaw thrust I-gel insertion technique in adults: a case series
    Dileep Kumar
    Journal of Medical Case Reports, 16
  • [23] Secure insertion of the i-gel supraglottic airway device in children A cohort study
    Sugiyama, Saori
    Yoshino, Jun
    Kinoshita, Hiroyuki
    Fujimura, Naoyuki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (02) : 145 - 147
  • [24] Insertion of the supraglottic airway device i-gel in the lateral position: Preliminary results
    Cuarental Garcia, A.
    Arevalo Ludena, J.
    Arcas Bellas, J. J.
    Alvarez-Rementeria Carbonell, R.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 252 - 252
  • [26] Effective concentration of remifentanil for successful i-gel insertion during remimazolam induction
    Choi, Jung Ju
    Jung, Wol Seon
    Chang, Young Jin
    Yoo, Seungbeom
    Kwak, Hyun Jeong
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2023, 76 (03) : 235 - 241
  • [27] Comparison of malposition of i-gel in pediatric patients after blind and CMAC guided insertion - A randomized controlled trial
    Kumar, Rakesh
    Bihani, Pooja
    Syal, Rashmi
    Mohammed, Sadik
    Chhabra, Swati
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1250 - 1250
  • [28] Phenomenon with I-gel airway?
    Baxter, S.
    ANAESTHESIA, 2008, 63 (11) : 1265 - 1265
  • [29] Does prewarming of i-gel improve insertion and ventilation in anaesthetised and paralysed patients? A prospective, randomised, control trial
    Reddy, Aamuktha Malyadha
    Varghese, Nita
    Herekar, Basavaraj
    Shenoy, Udupi Kailashnath
    SAUDI JOURNAL OF ANAESTHESIA, 2019, 13 (03) : 215 - 221
  • [30] I-gel and lightening of anaesthesia?
    Ghai, A.
    Saini, S.
    Hooda, S.
    ANAESTHESIA, 2009, 64 (10) : 1151 - 1151