摘要
Objective: This study was performed to evaluate the clinical usefulness of the adventitial inversion technique in acute type A aortic dissection, with special attention to the impact of this procedure on the postoperative status of false lumen evaluated by computed tomographic scan. Methods: From March 2001 to November 2004, 18 consecutive patients underwent emergent surgery for acute type A aortic dissection. Supracoronary graft replacement was performed in all the patients (ascending aorta/hemiarch replacement: 13/18 = 72%, total arch replacement: 5/18 = 28%). The adventitial inversion technique was used for both the proximal and the distal stump constructions of the dissected aortic watt without the aid of Teflon felt or biologic glue. Aortic regurgitation was treated with resuspension of the aortic commissures. Results: There were two hospital deaths and the overall hospital mortality rate was 11.1%. The mean postoperative blood loss was 635 +/- 214 ml and no reexploration was required in any of the patients. Postoperative computed tomography showed closure of the false lumen in aortic root, aortic arch, and proximal descending thoracic aorta in all of the surviving patients. Postoperative echocardiography demonstrated no aortic regurgitation in any of the patients. Two patients died late postoperatively from unrelated causes to aortic dissection. The remaining 14 patients are doing well without a second-stage operation for aortic root or distal aortic lesions during the follow-up period of 7-51 months (mean: 28 14 months). Conclusions: The adventitial inversion technique provides an excellent immediate hemostasis and facilitates thrombotic closure of the proximal and the distal false lumen in the treatment for acute type A aortic dissection. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:864 / 869
页数:6
相关论文
共 50 条
  • [21] Type a acute aortic dissection: Immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue
    Hata, M
    Shiono, M
    Sezai, A
    Iida, M
    Negishi, N
    Sezai, Y
    ANNALS OF THORACIC SURGERY, 2004, 78 (03): : 853 - 857
  • [22] AORTIC-VALVE REPAIR WITH FIBRIN GLUE FOR TYPE-A ACUTE AORTIC DISSECTION
    SEGUIN, JR
    PICARD, E
    FRAPIER, JM
    CHAPTAL, PA
    ANNALS OF THORACIC SURGERY, 1994, 58 (02): : 304 - 307
  • [23] USE OF SURGICAL GLUE WITHOUT REPLACEMENT IN THE TREATMENT OF TYPE-A AORTIC DISSECTION
    FABIANI, JN
    JEBARA, VA
    DELOCHE, A
    STEPHAN, Y
    CARPENTIER, A
    CIRCULATION, 1989, 80 (03) : 264 - 268
  • [24] A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection
    Wenbin Hu
    Yiran Zhang
    Lei Guo
    Jingya Fan
    Yuan Lu
    Liang Ma
    Journal of Cardiothoracic Surgery, 14
  • [25] A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection
    Hu, Wenbin
    Zhang, Yiran
    Guo, Lei
    Fan, Jingya
    Lu, Yuan
    Ma, Liang
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (1)
  • [26] The use of gelatin-resorcin-formalin glue in acute aortic dissection type A
    Fukunaga, S
    Karck, M
    Harringer, W
    Cremer, J
    Rhein, C
    Haverich, A
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (05) : 564 - 569
  • [27] Midterm results of aortic repair using a fabric neomedia and fibrin glue for type A acute aortic dissection
    Nakajima, Takayuki
    Kawazoe, Kohei
    Kataoka, Tsuyoshi
    Kin, Hajime
    Kazui, Toshinobu
    Okabayashi, Hitoshi
    Niinuma, Hiroyuki
    ANNALS OF THORACIC SURGERY, 2007, 83 (05): : 1615 - 1620
  • [28] Recent status of gelatin-resorcin-formalin glue for acute type A aortic dissection
    Imoto, Kiyotaka
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2011, 59 (05) : 313 - 314
  • [29] Open distal anastomosis technique in acute type A aortic dissection
    D Cvetkovic
    M Kocica
    Lj Soskic
    B Milicic
    N Aleksic
    M Ristic
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [30] Sandwich Technique for Endovascular Repair of Acute Type A Aortic Dissection
    Gao, Feng
    Zeng, Qian
    Lin, Fangming
    Ge, Xiaohu
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (05) : 647 - 653