A Vibro-Tactile Display for Clinical Monitoring: Real-Time Evaluation

被引:17
|
作者
Dosani, Maryam [1 ]
Hunc, Kate [1 ]
Dumont, Guy A. [2 ]
Dunsmuir, Dustin [1 ]
Barralon, Pierre [3 ]
Schwarz, Stephan K. W. [1 ]
Lim, Joanne [1 ]
Ansermino, J. Mark [1 ]
机构
[1] Univ British Columbia, Dept Anesthesiol Pharmacol & Therapeut, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
[3] Hlth Technol, TECNALIA, Donostia San Sebastian, Spain
来源
ANESTHESIA AND ANALGESIA | 2012年 / 115卷 / 03期
基金
加拿大健康研究院;
关键词
DETECTING CHANGES; IDENTIFICATION; CHILDREN; SYSTEMS; FOREARM; WRIST;
D O I
10.1213/ANE.0b013e31825d638c
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Vibro-tactile displays use human skin to convey information from physiological monitors to anesthesiologists, providing cues about changes in the status of the patient. In this investigation, we evaluated, in a real-time clinical environment, the usability and wearability of a novel vibro-tactile display belt recently developed by our group, and determined its accuracy in identifying events when used by anesthesiologists. METHODS: A prospective observational study design was used. During routine anesthesia, a standard physiological monitor was connected to a software tool that used algorithms to automatically identify changing trends in mean noninvasive arterial blood pressure, expired minute ventilation, peak airway pressure, and end-tidal carbon dioxide partial pressure. The software was wirelessly interfaced to a vibro-tactile belt worn by the anesthesiologist. Each physiological variable was mapped to 1 of 4 tactor locations within the belt. The direction (increase/decrease) and 2 levels of change (small/large) were encoded in the stimulation patterns. A training session was completed by each anesthesiologist. The system was activated in real-time during anesthesia alongside routine physiological monitors. When the algorithms detected changes in the patient, the belt vibrated at the appropriate location with the pattern corresponding to the level and direction of change. Using a touch screen monitor the anesthesiologist was to enter the vibro-tactile message by first identifying the variable, then identifying the level and direction of change. Usability and wearability questionnaires were to be completed. The percentage of correct identification of the physiological trend, the direction of change, and the level of change were primary outcome variables. The mean usability score and wearability results were secondary outcome variables. We hypothesized that anesthesiologists would correctly identify the events communicated to them through the vibro-tactile belt 90% of the time, and that anesthesiologists would find the vibro-tactile belt usable and wearable. RESULTS: Seventeen anesthesiologists evaluated the display during 57 cases. The belt was operational for a mean (SD) duration of 75 (41) minutes per case. Seven cases were excluded from analysis because of technical failures. Eighty-one percent (confidence interval [CI], 77% to 84%) of all stimuli were decoded. The physiological trend, the direction of change, and the level of change were correctly identified for 97.7% (CI 96%-99%), 94.9% (CI 92%-97%), and 93.5% of these stimuli (CI, 91%-96%), respectively. Fourteen anesthesiologists completed the usability and wearability questionnaires. The mean usability score was 4.8 of a maximum usability score of 7. CONCLUSIONS: Anesthesiologists found a vibro-tactile belt to be wearable and usable and could accurately decode vibro-tactile messages in a real-time clinical environment. (Anesth Analg 2012;115:588-94)
引用
收藏
页码:588 / 594
页数:7
相关论文
共 50 条
  • [1] An evaluation of a vibro-tactile display prototype for physiological monitoring
    Ng, JYC
    Man, JCF
    Fels, S
    Dumont, G
    Ansermino, JM
    [J]. ANESTHESIA AND ANALGESIA, 2005, 101 (06): : 1719 - 1724
  • [2] Development of Vibro-tactile Braille Display and Keyboard
    Aqel, Mohammad O. A.
    Issa, Ahmed
    Harb, Ahmad
    Shehada, Jehad
    [J]. 2019 INTERNATIONAL CONFERENCE ON PROMISING ELECTRONIC TECHNOLOGIES (ICPET 2019), 2019, : 28 - 33
  • [3] VibroSquare: Vibro-Tactile Display for Body-Centric Implicit Interactions
    Zhiglova, Yulia
    Lamas, David
    Smorgun, Ilja
    Pashaei, Amir Zare
    [J]. HUMAN-COMPUTER INTERACTION - INTERACT 2019, PT IV, 2019, 11749 : 572 - 576
  • [4] VITAL: A new low-cost VIbro-TActiLe display system
    Benali-Khoudja, M
    Hafez, M
    Alexandre, JM
    Kheddar, A
    Moreau, V
    [J]. 2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, : 721 - 726
  • [5] Evaluation of Visual, Auditory and Vibro-Tactile Alerts in Supervised Interfaces
    de Souza, Gabrielle Almeida
    Torres, Laura Amaya
    Dane, Vinicius Stein
    Villa, David Steeven
    Larico, Abel Ticona
    Maciel, Anderson
    Nedel, Luciana
    [J]. 2018 20TH SYMPOSIUM ON VIRTUAL AND AUGMENTED REALITY (SVR 2018), 2018, : 163 - 169
  • [6] Synchronising to a frequency while estimating time of vibro-tactile stimuli
    Casilimas-Diaz, David Andres
    Oliveira Bueno, Jose Lino
    [J]. EXPERIMENTAL BRAIN RESEARCH, 2019, 237 (05) : 1257 - 1266
  • [7] A new concept touch-sensitive display enabling vibro-tactile feedback
    Kawakami, M
    Mamiya, M
    Nishiki, T
    Tsuji, Y
    Okamoto, A
    Fujita, T
    [J]. PEOPLE AND COMPUTER XIII, PROCEEDINGS, 1998, : 303 - 312
  • [8] Synchronising to a frequency while estimating time of vibro-tactile stimuli
    David Andrés Casilimas-Díaz
    Jose Lino Oliveira Bueno
    [J]. Experimental Brain Research, 2019, 237 : 1257 - 1266
  • [9] Optimizing the tactile display of physiological information: Vibro-tactile vs. electro-tactile stimulation, and forearm or wrist location
    Ng, G.
    Barralon, P.
    Dumont, G.
    Schwarz, S. K. W.
    Ansermino, J. M.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4202 - 4205
  • [10] Vibro-tactile Feedback for Real-world Awareness in Immersive Virtual Environments
    Valkov, Dimitar
    Linsen, Lars
    [J]. 2019 26TH IEEE CONFERENCE ON VIRTUAL REALITY AND 3D USER INTERFACES (VR), 2019, : 340 - 349