Research and Realization of Automatic Dynamic Balance for Cross-Flow Fan by NC Drilling

被引:0
|
作者
Chen, Zhi [1 ]
Huang, Yu [1 ]
Ding, Bin [2 ]
机构
[1] Huazhong Univ Sci & Technol, Digital Mfg Equipment Laborers Engn Ctr Co Ltd, Wuhan, Hubei, Peoples R China
[2] Guangdong Sunwill Precising Plast Co Ltd, Foshan, Guangdong, Peoples R China
关键词
dynamic balance; cross-flow fan; NC drilling; PLC; two end-face equivalent balance;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The dynamic balance of cross-flow fan was primarily implemented by manual balance sheetmetal, and there are some shortcomings that low precision and easily fall off. In this paper, firstly, the mechanism of dynamic balance of cross-flow fan was elaborated. Then, the collection of unbalance is achieved by four pressure sensors, and the equivalent unbalances of end faces was obtained by the mechanisms of two end-face equivalent balance. And then, the NC drilling method was brought in cross-flow fan, and one or more holes drilling model were built, respectively. After that, the automatic dynamic balance equipment of cross-flow fan was developed by the PLC control system. Last, a set of experiment was come true on the independent equipment, and the result of experiment showed that the decrement rate of unbalance can reach 90%.
引用
收藏
页码:269 / 272
页数:4
相关论文
共 50 条
  • [31] AUTOMATIC-CONTROL OF CROSS-FLOW GRAIN DRYERS
    BAKKERARKEMA, FW
    MOREIRA, RG
    ELTIGANI, AY
    AGRICULTURAL ENGINEERING, VOLS 1-4: LAND AND WATER USE, AGRICULTURAL BUILDINGS, AGRICULTURAL MECHANISATION, POWER, PROCESSING AND SYSTEMS, 1989, : 2199 - 2204
  • [32] Dynamic response of circular cylinders in cross-flow
    Albedoor, BO
    Almusallam, A
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 66 (01) : 69 - 84
  • [33] Performance of a cross-flow fan with various shapes of a rearguider and an exit duct
    Tae-An Kim
    D. -W. Kim
    S. -K. Park
    Youn J. Kim
    Journal of Mechanical Science and Technology, 2008, 22 : 1876 - 1882
  • [34] Effects of cross-flow fan on hydrodynamic and acoustic performance of underwater fan-wing thruster
    Gao, Tianzhu
    Lin, Yang
    Qiu, Liang
    Tse, Zion Tsz Ho
    Ren, Hongliang
    OCEAN ENGINEERING, 2021, 241
  • [35] Computational and experimental study of a cross-flow fan for combine cleaning shoes
    Gebrehiwot, M. G.
    De Baerdemaeker, J.
    Baelmans, M.
    CONFERENCE: AGRICULTURAL ENGINEERING - LAND-TECHNIK AGENG 2009: INNOVATIONS TO MEET FUTURE CHALLENGES, 2009, 2060 : 387 - 392
  • [36] Application of acoustically transparent plenum to noise of cross-flow fan system
    Jung, IH
    Jin, SW
    Chung, BY
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 840 - 843
  • [37] AIR-JET VELOCITIES FROM A CROSS-FLOW FAN SPRAYER
    FOX, RD
    BRAZEE, RD
    SVENSSON, SA
    REICHARD, DL
    TRANSACTIONS OF THE ASAE, 1992, 35 (05): : 1381 - 1382
  • [38] Window purifying ventilator using a cross-flow fan: Simulation and optimization
    Li, Jiayu
    Hou, Yuefei
    Liu, Junjie
    Wang, Zhiqiang
    Li, Fei
    BUILDING SIMULATION, 2016, 9 (04) : 481 - 488
  • [39] Forces on apple trees sprayed with a cross-flow fan air jet
    Svensson, SA
    Fox, RD
    Hansson, PA
    TRANSACTIONS OF THE ASAE, 2002, 45 (04): : 889 - 895
  • [40] Performance of a cross-flow fan with various shapes of a rearguider and an exit duct
    Kim, Tae-An
    Kim, D-W.
    Park, S-K.
    Kim, Youn J.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2008, 22 (10) : 1876 - 1882