Ultra-sensitive detection of kanamycin for food safety using a reduced graphene oxide-based fluorescent aptasensor

被引:84
|
作者
Ha, Na-Reum [1 ,2 ]
Jung, In-Pil [1 ,2 ]
La, Im-Joung [3 ]
Jung, Ho-Sup [4 ]
Yoon, Moon-Young [1 ,2 ]
机构
[1] Hanyang Univ, Dept Chem, Seoul 04763, South Korea
[2] Hanyang Univ, Res Inst Nat Sci, Seoul 04763, South Korea
[3] Lotte Confectionery Co Ltd, Food Safety Ctr, Seoul 07207, South Korea
[4] Seoul Natl Univ, Dept Mech & Aerosp Engn, Inst Adv Machinery & Design, Seoul 08826, South Korea
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
关键词
SELECTIVE DETECTION; ELECTROCHEMICAL APTASENSOR; COLORIMETRIC DETECTION; APTAMER; NANOPARTICLES; BIOSENSOR; SENSOR; ASSAY;
D O I
10.1038/srep40305
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Overuse of antibiotics has caused serious problems, such as appearance of super bacteria, whose accumulation in the human body through the food chain is a concern. Kanamycin is a common antibiotic used to treat diverse infections; however, residual kanamycin can cause many side effects in humans. Thus, development of an ultra-sensitive, precise, and simple detection system for residual kanamycin in food products is urgently needed for food safety. In this study, we identified kanamycin-binding aptamers via a new screening method, and truncated variants were analyzed for optimization of the minimal sequence required for target binding. We found various aptamers with high binding affinity from 34.7 to 669 nanomolar K-d(app) values with good specificity against kanamycin. Furthermore, we developed a reduced graphene oxide (RGO)-based fluorescent aptasensor for kanamycin detection. In this system, kanamycin was detected at a concentration as low as 1 pM (582.6 fg/mL). In addition, this method could detect kanamycin accurately in kanamycin-spiked blood serum and milk samples. Consequently, this simple, rapid, and sensitive kanamycin detection system with newly structural and functional analysis aptamer exhibits outstanding detection compared to previous methods and provides a new possibility for point of care testing and food safety.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A Novel Graphene Oxide-Based Aptasensor for Amplified Fluorescent Detection of Aflatoxin M1 in Milk Powder
    Guo, Xiaodong
    Wen, Fang
    Qiao, Qinqin
    Zheng, Nan
    Saive, Matthew
    Fauconnier, Marie-Laure
    Wang, Jiaqi
    SENSORS, 2019, 19 (18)
  • [32] Fluorescence resonance energy transfer-based aptasensor for sensitive detection of kanamycin in food
    Zhang, Yunlian
    Liu, Rui
    Hassan, Md Mehedi
    Li, Huanhuan
    Ouyang, Qin
    Chen, Quansheng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 262
  • [33] Graphene Oxide-Based Biosensor for Food Toxin Detection
    Saurabh Srivastava
    Md Azahar Ali
    Sima Umrao
    Upendra Kumar Parashar
    Anchal Srivastava
    Gajjala Sumana
    B. D. Malhotra
    Shyam Sudhir Pandey
    Shuji Hayase
    Applied Biochemistry and Biotechnology, 2014, 174 : 960 - 970
  • [34] Graphene Oxide-Based Biosensor for Food Toxin Detection
    Srivastava, Saurabh
    Ali, Md Azahar
    Umrao, Sima
    Parashar, Upendra Kumar
    Srivastava, Anchal
    Sumana, Gajjala
    Malhotra, B. D.
    Pandey, Shyam Sudhir
    Hayase, Shuji
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 174 (03) : 960 - 970
  • [35] Graphene oxide based fluorescent aptasensor for adenosine deaminase detection using adenosine as the substrate
    Xing, Xiao-Jing
    Liu, Xue-Guo
    Yue-He
    Luo, Qing-Ying
    Tang, Hong-Wu
    Pang, Dai-Wen
    BIOSENSORS & BIOELECTRONICS, 2012, 37 (01): : 61 - 67
  • [36] An ultra-sensitive hydrogen gas sensor using reduced graphene oxide-loaded ZnO nanofibers
    Ul Abideen, Zain
    Kim, Hyoun Woo
    Kim, Sang Sub
    CHEMICAL COMMUNICATIONS, 2015, 51 (84) : 15418 - 15421
  • [37] Ultra-Sensitive and Responsive Capacitive Humidity Sensor Based on Graphene Oxide
    Ye, Qiangqiang
    Wen, Chenyu
    Xu, Ming
    Zhang, Shi-Li
    Wu, Dongping
    PROCEEDINGS OF 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2015,
  • [38] MXene-AuNP-Based Electrochemical Aptasensor for Ultra-Sensitive Detection of Chloramphenicol in Honey
    Yang, Jing
    Zhong, Wei
    Yu, Qi
    Zou, Jin
    Gao, Yansha
    Liu, Shuwu
    Zhang, Songbai
    Wang, Xiaoqiang
    Lu, Limin
    MOLECULES, 2022, 27 (06):
  • [39] A novel bioconjugated reduced graphene oxide-based nanocomposite for sensitive electrochemical detection of cadmium in water
    Bhardiya, Smita R.
    Asati, Ambika
    Sheshma, Harendra
    Rai, Ankita
    Rai, Vijai K.
    Singh, Manorama
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 328 (328):
  • [40] A 3D scaffold for ultra-sensitive reduced graphene oxide gas sensors
    Yun, Yong Ju
    Hong, Won G.
    Choi, Nak-Jin
    Park, Hyung Ju
    Moon, Seung Eon
    Kim, Byung Hoon
    Song, Ki-Bong
    Jun, Yongseok
    Lee, Hyung-Kun
    NANOSCALE, 2014, 6 (12) : 6511 - 6514