Condition Monitoring of Power Feeder with Multiple Parallel Cables Based on Inductive Coupling Method

被引:0
|
作者
Li, Kangrong [1 ]
See, Kye-Yak [1 ]
Narampanawe, Nishshanka Bandara [1 ]
Weerasinghe, Arjuna [1 ]
Tong, Victor Ho Yao [2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore, Singapore
[2] SBS Transit Ltd, Singapore, Singapore
来源
2018 INTERNATIONAL CONFERENCE ON INTELLIGENT RAIL TRANSPORTATION (ICIRT) | 2018年
关键词
condition monitoring; in-circuit impedance measurement; railway substation; multiple parallel cables;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A non-intrusive method for monitoring the health condition of power feeder with parallel cables is proposed and developed. The proposed method is based on an inductive coupling technology and therefore it does not affect the normal operation of the actual electrical system and can be easily deployed on-site without any modification to the feeder structure.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Automatic Active Compensation Method of Cross-Coupling in Multiple-receiver Resonant Inductive Coupling Wireless Power Transfer Systems
    Ishihara, Masataka
    Fujiki, Keita
    Umetani, Kazuhiro
    Hiraki, Eiji
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 4584 - 4591
  • [32] Need for condition monitoring and diagnosis of electric wires and cables used in nuclear power plants
    Ohki, Yoshimichi
    Hirai, Naoshi
    Yamamoto, Toshio
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1207 - +
  • [33] Power Transformer Condition Monitoring and Performance Calculation Method based on Information Fusion
    Octavianus, Karel
    Anggoro, Bambang
    Ahmad, Adang Suwandi
    2015 INTERNATIONAL CONFERENCE QUALITY IN RESEARCH (QIR), 2015, : 163 - 166
  • [34] Research on Condition Monitoring Method for Nuclear Power Plants Based on Data Drive
    Yao P.
    Yao, Pengchuan (3320408036@qq.com), 1600, Yuan Zi Neng Chuban She (41): : 135 - 139
  • [35] On-Line Condition Monitoring and Aging Management System for Nuclear Power Plant Cables
    McConkey, J. Bryan
    Dungan, Nathan A.
    Ferree, Codi R.
    Ellis, Patrick N.
    Connatser, Elijah B.
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 252 - 255
  • [36] Insulation Condition Monitoring in High Voltage Power Cables using Partial Discharge Measurements
    Adhikari, Neha
    2021 12TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2021,
  • [37] Electrical Condition Monitoring of Low Voltage Nuclear Power Plant Cables: tang and Capacitance
    Asipuela, Angel
    Mustafa, Ehtasham
    Afia, Ramy S. A.
    Adam, Tamus Zoltan
    Khan, Muhammad Yousaf Ali
    2018 4TH INTERNATIONAL CONFERENCE ON POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET-2018), 2018, : 332 - 335
  • [38] Aging and condition monitoring studies of composite insulation cables used in nuclear power plants
    Anandakumaran, K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (01) : 227 - 237
  • [39] QUALIFICATION, CONDITION MONITORING AND MANAGEMENT OF AGEING OF LOW VOLTAGE CABLES IN NUCLEAR POWER PLANT
    Kang, Ki Sig
    ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2015, VOL 7, 2015,
  • [40] On-site condition monitoring of HV power cables up to 150kV
    Gulski, E.
    Cichecki, P.
    Smit, J. J.
    Seitz, P. P.
    Quak, B.
    de Vries, F.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1199 - +