Gamma electron vertex imaging and application to beam range verification in proton therapy

被引:43
|
作者
Kim, Chan Hyeong [1 ]
Park, Jin Hyung [1 ]
Seo, Hee [1 ]
Lee, Han Rim [1 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
proton therapy; prompt gamma; range verification; gamma electron vertex imaging; RAY TELESCOPES; CAMERA; DETECTOR;
D O I
10.1118/1.3662890
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper describes a new gamma-ray imaging method, "gamma electron vertex imaging (GEVI)," which can be used for precise beam range verification in proton therapy. Methods: In GEVI imaging, the high-energy gammas from a source or nuclear interactions are first converted, by Compton scattering, to electrons, which subsequently are traced by hodoscopes to determine the location of the gamma source or the vertices of the nuclear interactions. The performance of GEVI imaging for use in-beam range verification was evaluated by Monte Carlo simulations employing GEANT4 equipped with the QGSP_BIC_HP physics package. Results: Our simulation results show that GEVI imaging can determine the proton beam range very accurately, within 2-3 mm of error, even without any sophisticated analysis. The results were obtained under simplified conditions of monoenergetic pencil beams stopped in a homogeneous phantom and on the basis of the obtained results it is expected to achieve submillimeter accuracy in proton beam range measurement. Conclusions: If future experimental work confirms the simulated results presented in this paper, the use of GEVI imaging is expected to have a great potential in increasing the accuracy of proton beam range verification in a patient, resulting in significant improvement of treatment effectiveness by enabling tight conformation of radiation dose to the tumor volume and patient safety. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3662890]
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 50 条
  • [31] A Simple Technique for Proton Beam Range Verification
    Burgdorf, B.
    Kassaee, A.
    Garver, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3348 - 3348
  • [32] PET application as a Compton camera for proton beam range verification: A preliminary study
    Kozani, Majid Kazemi
    Rucinski, Antoni
    Moskal, Pawel
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 23 - 30
  • [33] Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
    Balibrea-Correa, J.
    Lerendegui-Marco, J.
    Ladarescu, I
    Guerrero, C.
    Rodriguez-Gonzalez, T.
    Jimenez-Ramos, M. C.
    Fernandez-Martinez, B.
    Domingo-Pardo, C.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (11):
  • [34] Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
    J. Balibrea-Correa
    J. Lerendegui-Marco
    I. Ladarescu
    C. Guerrero
    T. Rodríguez-González
    M. C. Jiménez-Ramos
    B. Fernández-Martínez
    C. Domingo-Pardo
    The European Physical Journal Plus, 137
  • [35] Proton-Acoustic Range Verification in Proton Therapy
    Ahmad, M.
    Xiang, L.
    Xing, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3679 - 3679
  • [36] Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy
    Shin, H.
    Yoon, D.
    Jung, J.
    Kim, M.
    Jang, H.
    Suh, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3583 - 3583
  • [37] Dose verification in proton therapy via imaging gamma-ray emission
    Feng, Y.
    Baciak, J. E.
    Haghighat, A.
    MEDICAL PHYSICS, 2007, 34 (06) : 2574 - 2574
  • [38] Electromagnetic Signal of a Proton Beam in Biological Tissues for a Potential Range-Verification Approach in Proton Therapy
    Raedler, Martin
    Gianoli, Chiara
    Palaniappan, Prasannakumar
    Parodi, Katia
    Riboldi, Marco
    PHYSICAL REVIEW APPLIED, 2021, 15 (02)
  • [39] Can Prompt Gamma Emission During Proton Therapy Provide in Situ Range Verification?
    Styczynski, J.
    Riley, K.
    Binns, P.
    Bortfeld, T.
    Paganetti, H.
    MEDICAL PHYSICS, 2009, 36 (06) : 2425 - +
  • [40] Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning
    Tian, Liheng
    Huang, Ze
    Janssens, Guillaume
    Landry, Guillaume
    Dedes, George
    Kamp, Florian
    Belka, Claus
    Pinto, Marco
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):