The experimental verification of metrological properties of direct current Watt-hour meter

被引:1
|
作者
Otomanski, P. [1 ]
Zazula, P. [1 ]
机构
[1] Poznan Univ Tech, Inst Elect Engn & Elect, PL-60965 Poznan, Poland
关键词
D O I
10.1088/1742-6596/459/1/012058
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The paper presents a method for evaluating the accuracy of indications of the direct current Watt-hour meters in a designed and constructed measuring system. Such measuring system is composed of two multi-function calibrators, and a specialised high-voltage attachment dedicated for this system, which makes it possible to generate direct voltages in a required range up to 4 kV with a suitably high precision. The authors described in detail particular elements of the measuring system together with the results of its calibration. They showed the results of experiments carried out on a large and representative number of LE3000plus Watt-hour meter items.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Communication Driven Technology Research On Mine Watt-Hour Meter MCGS Management System
    Meng, Xiang-Zhong
    Hou, Zi-Sheng
    Wang, Wen-Chao
    Liu, Hui-Long
    INTERNATIONAL CONFERENCE ON CONTROL ENGINEERING AND AUTOMATION (ICCEA 2014), 2014, : 139 - 144
  • [32] Protocol construction of Remote Watt-hour Meter reading system using SMS Platform
    Shi, JH
    Chen, HH
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 2, 2005, : 224 - 229
  • [33] A Design of Three-Phase Digital Watt-Hour Power Meter on SOPC Platform
    Sun Hao
    Yuan Huimei
    Lu Simei
    2009 INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND COMPUTER SCIENCE, VOL 1, PROCEEDINGS, 2009, : 264 - 267
  • [34] The Design of a Novel Multi-rate Three-phase Watt-hour Meter
    Jiang, Jishun
    Yu, Lanlan
    PROCEEDINGS OF 2009 INTERNATIONAL WORKSHOP ON INFORMATION SECURITY AND APPLICATION, 2009, : 240 - 243
  • [35] Failure aspects of electronic watt-hour meters due to direct lightning strikes to distribution lines - Electromagnetic disturbance caused by lightning current flowing through watt-hour meters and its countermeasure-
    Ishimoto K.
    Mori R.
    Asakawa A.
    Ohki Y.
    Ishimoto, Kazuyuki (ishimoto@criepi.denken.or.jp), 1600, Institute of Electrical Engineers of Japan (137): : 766 - 776
  • [36] Drawback of Using Double Core Current Transformers in Static Watt-Hour Meters
    Mlejnek, P.
    Kaspar, P.
    SENSOR LETTERS, 2009, 7 (03) : 394 - 396
  • [37] Display quality detection method for a two-screen watt-hour meter based on domain adaptation
    Liu Y.
    Tan G.
    Liu X.
    Xu X.
    Huang Y.
    Wu L.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (23): : 180 - 187
  • [38] EFFICIENT BUILT-IN SELF-TEST OF A HIGH-PRECISION ELECTRONIC WATT-HOUR METER
    Ribnikar, Rok
    Bizjak, Uros
    Strle, Drago
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2011, 41 (03): : 222 - 228
  • [39] FTA-Based Reliability Research on Fully Electronic Multi-Functional Watt-Hour Meter
    Zhang Jingchao
    Chen Zhuoya
    Zhou Qi
    Chen Rui
    TECHNOLOGY AND APPLICATION OF ELECTRONIC INFORMATION, 2009, : 389 - 392
  • [40] Designing radio-frequency electromagnetic field immunity of watt-hour meter test system based on LabVIEW
    Bo, Zhao
    Ping, Song
    CEEM' 2006: ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, VOLS 1 AND 2, PROCEEDINGS, 2006, : 434 - +