Sensitivity of the Jamar dynamometer in detecting submaximal grip effort

被引:48
|
作者
Ashford, RF
Nagelburg, S
Adkins, R
机构
[1] Rancho Los Amigos Medical Center, Pasadena, CA 91103
来源
关键词
D O I
10.1016/S0363-5023(96)80352-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Twenty-two people with no extremity disability were tested in a standard fashion using the Jamar Dynamometer to establish their maximum grip strength. Each participant was asked to grip first right-handed then left-handed three consecutive times. The directions were re-explained so that each participant would give a consistent, less than optimal effort; three trials right and three trials left were recorded, The standard deviations of each set of these trials were calculated for both right and left hands. These standard deviations were then tabulated as scores for 44 trials of 22 patients, both hands, for maximal and submaximal efforts, These scores were then compared, maximal versus submaximal, using a paired t-test, We found no statistical difference in the two groups in comparing the variability of results, Therefore, the current protocol for Jamar testing can allow a patient to make a consistently submaximal effort, resulting in a false apparent loss of grip strength.
引用
收藏
页码:402 / 405
页数:4
相关论文
共 50 条
  • [31] Sensitivity and specificity of the blankenship FCE system's indicators of submaximal effort
    Brubaker, Perry N.
    Fearon, Frank J.
    Smith, Stephen M.
    McKibben, Richard J.
    Alday, James
    Andrews, Stacie S.
    Clarke, Everald
    Shaw, George L., Jr.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2007, 37 (04): : 161 - 168
  • [32] PORTABLE HAND-GRIP DYNAMOMETER
    PEARN, J
    BULLOCK, K
    AUSTRALIAN PAEDIATRIC JOURNAL, 1979, 15 (02): : 107 - 109
  • [33] Estimation of grip force using the Grip-ball dynamometer
    Chkeir, Aly
    Jaber, Rana
    Hewson, David J.
    Duchene, Jacques
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (11) : 1698 - 1702
  • [34] NEW HAND-GRIP DYNAMOMETER
    PEARN, J
    BULLOCK, K
    AUSTRALIAN PAEDIATRIC JOURNAL, 1977, 13 (02): : 146 - 146
  • [35] Gripwise Versus Jamar: The Challenge of a New Dynamometer Assessing Handgrip Strength
    Villain, Cedric
    Lebaube, Soazig
    Kremer, Corinne
    Chavoix, Chantal
    Fournel, Francois
    Briant, Anais R.
    Beauplet, Berengere
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2023, 78 (12): : 2458 - 2465
  • [36] Concordance of grip strength measurement between a digital handheld dynamometer and a Hydraulic dynamometer
    Segura-Duarte, Amor A.
    Mendez-Suarez, Gerardo
    Burgos-Morelos, Laura P.
    Rivera-Sanchez, Jose J.
    GACETA MEDICA DE MEXICO, 2024, 160 (03): : 322 - 326
  • [37] VOLUNTARY CONTROL OF SUBMAXIMAL GRIP STRENGTH
    NIEBUHR, BR
    MARION, R
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1990, 69 (02) : 96 - 101
  • [38] Intrarater and Interrater Reliabilities for a Toe Grip Dynamometer
    Uritani, Daisuke
    Fukumoto, Takahiko
    Matsumoto, Daisuke
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2012, 24 (08) : 639 - 643
  • [39] The Comprehensive Muscular Activity Profile (CMAP): Its High Sensitivity, Specificity and Overall Classification Rate for Detecting Submaximal Effort on Functional Capacity Testing
    Robert J. Gatchel
    Mark D. Ricard
    Dhruti N. Choksi
    Jain Mayank
    Krista Howard
    Journal of Occupational Rehabilitation, 2009, 19 : 49 - 55
  • [40] The Comprehensive Muscular Activity Profile (CMAP): Its High Sensitivity, Specificity and Overall Classification Rate for Detecting Submaximal Effort on Functional Capacity Testing
    Gatchel, Robert J.
    Ricard, Mark D.
    Choksi, Dhruti N.
    Mayank, Jain
    Howard, Krista
    JOURNAL OF OCCUPATIONAL REHABILITATION, 2009, 19 (01) : 49 - 55