Piezoelectric fiber composite transducers for health monitoring in composite structures

被引:60
|
作者
Konka, Hari P. [1 ]
Wahab, M. A. [1 ]
Lian, K. [2 ]
机构
[1] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
[2] XAng Jiaotong Univ, Suzhou Sch Nanosci & Nanoengn, Sozhou Ind Pk 215123, Peoples R China
关键词
Piezoelectric material; Piezoelectricity; Macro-fiber composite; Strain gauges; Sensing characteristics; Dynamic loading; Composite structures; Modal analysis; DAMAGE DETECTION; SYSTEM;
D O I
10.1016/j.sna.2012.12.039
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a critical study on the sensing characteristics of piezoelectric fiber composite transducers (PFCTs), in order to evaluate them as an effective embedded sensor inside the composite structures to monitor the stress/strain concentration levels at the critical locations. The functions of PFCT as an embedded sensor inside the composite structure are threefold: (i) to detect all loading conditions acting on to the structure, (ii) to predict the occurrence of damage while in-service under dynamic loads, and (iii) to monitor the pre-existing damages in the composite structures so that the severity can be ascertained to avoid eventual catastrophic or brittle failures. PFCT will be an ideal choice for composite structures applications, as they are highly flexible, easily embeddable; their high compatibility to the composite manufacturing techniques, and more importantly, it is expected that they will produce significantly less interfacial stresses when embedded inside the composite structures. Two types of PFCTs (macro fiber composite (MFC - from Smart Materials Corp.), and piezoelectric fiber composite (PFC - from Advance Cerametrics Inc.)) have been selected and calibrated by investigating their sensor performances based on characteristics; like transfer function, sensitivity, nonlinearity, resolution, and noise levels. Dynamic loads (transverse and longitudinal) have been applied and their corresponding output response is evaluated. The sensitivity of these products to the changes in frequencies and strain levels of input dynamic loads is investigated through the constant strain and frequency curves. Healthy voltage output response is observed even at low strain level domains, which indicates their high sensitivity and high resolution as a sensor. Comparing the results, it can be concluded that these sensors demonstrated their superior sensitivity and better performance over the traditional strain gauges. After a detailed sensor performance assessment, a case study has been conducted on the composite beam structure, where the ability of the PFCTs to detect the delamination of various levels inside the composite beam structure through modal analysis has been investigated. Then tests were performed to investigate the ability of the embedded PFCT sensors to detect the changes in the applied input mechanical stress/strain when embedded inside glass fiber epoxy composite laminate samples. It is found that these sensors are effectively able to detect the changes in the applied input mechanical stress/strain. A linear relationship has been observed between the applied input mechanical stress and the sensor generated voltage output. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 94
页数:11
相关论文
共 50 条
  • [41] Fiber-reinforced Composite Structures with Embedded Piezoelectric Sensors
    Schulze, R.
    Streit, P.
    Fischer, T.
    Tsapkolenko, A.
    Heinrich, M.
    Sborikas, M.
    Kroll, L.
    Gessner, T.
    Wegener, M.
    2014 IEEE SENSORS, 2014,
  • [42] PIEZOELECTRIC COMPOSITE TRANSDUCERS FOR ULTRASONIC DIAGNOSTIC APPLICATIONS
    BUI, T
    CHAN, HLW
    UNSWORTH, J
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (06) : 813 - 813
  • [43] Analytical solution of piezoelectric composite stack transducers
    Wang, Jianjun
    Shi, Zhifei
    Han, Zhijun
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2013, 24 (13) : 1626 - 1636
  • [44] DYNAMIC LUMPED PARAMETERS OF COMPOSITE PIEZOELECTRIC TRANSDUCERS
    CHERPAK, VA
    SOVIET PHYSICS ACOUSTICS-USSR, 1977, 23 (03): : 246 - 250
  • [45] COMPOSITE PIEZOELECTRIC TRANSDUCERS FOR ULTRASONIC MEDICAL IMAGING
    GURURAJA, TR
    SCHULZE, WA
    NEWNHAM, RE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (10) : 873 - 873
  • [46] Novel piezoelectric ceramic/polymer composite transducers
    Turcu, S
    Jadidian, B
    Danforth, SC
    Rutgers, AS
    ISAF 2002: PROCEEDINGS OF THE 13TH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, 2002, : 307 - 310
  • [47] Monitoring of composite structures using a network of integrated PVDF film transducers
    Guzman, Enrique
    Cugnoni, Joel
    Gmuer, Thomas
    SMART MATERIALS AND STRUCTURES, 2015, 24 (05)
  • [48] Flexible piezoelectric composite sensor for impact monitoring of curved structures
    Jiang, Shuai
    Shen, Yiping
    Wang, Songlai
    Jiang, Wei
    Liu, Yi
    Wu, Qizhou
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 362
  • [49] HEALTH MONITORING OF COMPOSITE REPAIRS OF AIRCRAFT STRUCTURES
    Ruzicka, M.
    Kulisek, V
    Henzl, P.
    Krimbalis, P.
    Dvorak, M.
    Behal, J.
    EUROPEAN NDT DAYS IN PRAGUE 2007: NDE FOR SAFETY, PROCEEDINGS, 2007, : 209 - 218
  • [50] On-line health monitoring of smart composite structures using fiber polarimetric sensor
    Murukeshan, V.M.
    Chan, P.Y.
    Seng, Ong Lin
    Asundi, A.
    Smart Materials and Structures, 1999, 8 (05): : 544 - 548