Numerical investigation and analysis of indoor air quality in a room based on impinging jet ventilation

被引:4
|
作者
Koufi, Lounes [1 ,2 ,3 ]
Younsi, Zohir [2 ,3 ]
Cherif, Yassine [1 ,3 ]
Naji, Hassane [1 ,3 ]
机构
[1] Univ Artois, EA 4515, LGCgE, EA 4515, F-62400 Bethune, France
[2] FUPL, LGCgE, Hautes Etud Ingn, 13 Rue Toul, F-59000 Lille, France
[3] Univ Lille, LGCGE, F-59000 Lille, France
关键词
CFD simulation; impinging jet ventilation; indoor air quality; ventilation efficiency; turbulence; TURBULENCE MODELS; FLOWS; CONVECTION; BEHAVIOR; FLUID; HEAT;
D O I
10.1016/j.egypro.2017.11.276
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents numerical investigation and analysis of carbon dioxide transport (CO2) within an isothermal three-dimensional room using impinging jet ventilation (IJV). The IJV is an effective strategy for use in buildings. The study is carried out under turbulent and transient flow regime. The URANS equations supplemented with energy and concentration equations are solved using the scStream code. We are targeting primarily the efficiency of the ventilation epsilon(C) and the index of indoor air quality (I-IAQ). The ventilation flow rate is 50 m(3).h(-1). Here, our ultimate aim is to analyse the behaviour of the flow and repartition of CO2 inside the room. The RNG k-epsilon model was adopted to handle the turbulence. CFD simulations were systematically checked through available experimental and/or numerical results. The obtained results indicated that the IJV ensures a homogeneous concentration distribution and a velocity of the ambient air less than 0.25 m.s(-1). This is in agreement with the recommendations of ASHRAE Standard 55. The comparative results demonstrate that the IJV evacuates sufficiently the CO2 and ensures good air quality in an acceptable time. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:710 / 717
页数:8
相关论文
共 50 条
  • [41] Numerical investigation of the flow and heat behaviours of an impinging jet
    Wang, Peng
    Lv, Jizu
    Bai, Minli
    Wang, Yuyan
    Hu, Chengzhi
    [J]. INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2014, 28 (6-10) : 301 - 315
  • [42] A numerical framework for the analysis of indoor air quality in a classroom
    Mahmoud, Mohamed Mahmoud Abdelkareem
    Bahl, P.
    Aquino, A. F. V. de A.
    Maclntyre, C. R.
    Bhattacharjee, S.
    Green, D.
    Cooper, N.
    Doolan, C.
    de Silva, C.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 92
  • [43] Effect of Design Parameters on Indoor Temperature Distribution in Impinging Jet Ventilated Room
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Choi, Narae
    Matsuzaki, Mako
    [J]. IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [44] An experimental and numerical analysis of impinging jet flow
    Baydar, E
    Çuhadaroglu, B
    [J]. ENERGY AND THE ENVIRONMENT, 1999, : 445 - 447
  • [45] Field investigation of indoor air quality and ventilation characteristics in selected Irish houses
    Guo, LY
    Lewis, J
    Kelly, A
    Lennon, D
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 691 - 697
  • [46] Investigation of air pollution mitigation measures, ventilation, and indoor air quality at three schools in London
    Abhijith, K. V.
    Kukadia, Vina
    Kumar, Prashant
    [J]. ATMOSPHERIC ENVIRONMENT, 2022, 289
  • [47] Effect of quality and maintenance of the ventilation to the indoor air quality
    Niskanen, J
    Valkeapää, A
    Anttonen, H
    [J]. PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 168 - 171
  • [48] NUMERICAL ANALYSIS OF EFFECT OF IMPINGING JET ON COOLING OF SOLAR AIR HEATER WITH LONGITUDINAL FINS
    Pazarlioglu, Hayati Kadir
    Ekiciler, Recep
    Arslan, Kamil
    [J]. HEAT TRANSFER RESEARCH, 2021, 52 (11) : 47 - 61
  • [49] Computational investigation on the factors influencing thermal comfort for impinging jet ventilation
    Chen, Huijuan
    Moshfegh, Bahram
    Cehlin, Mathias
    [J]. BUILDING AND ENVIRONMENT, 2013, 66 : 29 - 41
  • [50] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229