Development of a seven-region lumped parameter nonlinear dynamic model for U-tube recirculation nuclear steam generator

被引:3
|
作者
Zhong, Xianping [1 ]
Guo, Pengya [1 ]
Zhang, Xiaolong [1 ]
Saeed, Muhammad [1 ]
Ma, Haoran [1 ]
Huang, Jianqi [1 ]
Yu, Jiyang [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
关键词
UTSG; Lumped parameter; Nonlinear dynamic model; Transient analysis; CONTROL-SYSTEM DESIGN; HEAT-TRANSFER; SIMULATION;
D O I
10.1016/j.anucene.2022.109190
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A lumped parameter nonlinear dynamic model for U-tube recirculation steam generator (UTSG) transient analysis is developed based on the conservation laws of mass, momentum and energy. UTSG is modeled by being divided into seven regions (control volumes), namely, primary-side region, steam region, waterdowncomer region, subcooled region of heated rising channel, boiling region of heated rising channel, unheated rising section and water-steam separator region, and heat transfer tube region. The model is verified with the published models. The comparison results show that the accuracy of the steady-state simulation, the trend and most amplitudes of the transient response of this model are consistent with those of the published models, which supports the reliability of this model. This model can be used for the development of the steam dump and bypass control system and as a simulation module for coupling with the primary loop system. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 29 条
  • [21] A lumped parameter dynamic model of the helical coiled once-through steam generator with movable boundaries
    Li, Haipeng
    Huang, Xiaojin
    Zhang, Liangju
    NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (07) : 1657 - 1663
  • [22] Simplification of Critical Criteria for Reverse Flow Determination Based on Reverse Flow Theory Model of U-Tube Steam Generator
    Liu H.
    Ma Z.
    Jiang Z.
    Tang Y.
    Zhang L.
    Xu J.
    Sun W.
    Yuan D.
    Pan L.
    Zhou W.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (06): : 77 - 81
  • [23] A 2-FLUID 2-PHASE MODEL FOR THERMAL-HYDRAULIC ANALYSIS OF A U-TUBE STEAM-GENERATOR
    HUNG, HJ
    CHIENG, CC
    PEI, BS
    WANG, SF
    NUCLEAR TECHNOLOGY, 1993, 101 (02) : 227 - 236
  • [24] Water level control of U-tube steam generator based on model-based active disturbance rejection control method
    Ma, Qian
    Fan, Ziqi
    Zhang, Xianshan
    Sun, Peiwei
    Wei, Xinyu
    ANNALS OF NUCLEAR ENERGY, 2024, 206
  • [25] EXPERIMENTAL STUDY ON MODEL DEVELOPMENT FOR LIQUID ACCUMULATION IN STEAM GENERATOR U-TUBE (FIRST REPORT) CONDENSING COUNTER-CURRENT FLOW IN SINGLE VERTICAL PIPE
    Yamaji, Tatsuya
    Yamazaki, Kohei
    Koizumi, Yasuo
    Ohtake, Hiroyasu
    Hasegawa, Koji
    Araki, Shota
    Ohnuki, Akira
    Nishi, Hiroaki
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 5, 2014,
  • [26] Research on Single-phase Inter-tube Pulsation Characteristics in Inverted U-tube of Steam Generator Based on Single-phase Compressible Model
    Li Z.
    Ma Z.
    Zhang D.
    Bu S.
    Sun W.
    Zhang L.
    Zhu L.
    Hedongli Gongcheng/Nuclear Power Engineering, 2022, 43 (05): : 56 - 62
  • [28] A 3D model to solve U-tube steam generator secondary side thermal-hydraulics with coupled primary-to-secondary side heat transfer
    Vivaldi, D.
    NUCLEAR ENGINEERING AND DESIGN, 2020, 370