Sensor Fusion on Structural Monitoring Data Analysis: Application to a Cable-Stayed Bridge

被引:5
|
作者
Zonta, Daniele [1 ]
Bruschetta, Federico [1 ]
Zandonini, Riccardo [1 ]
Pozzi, Matteo [2 ]
Ming-Wang [3 ]
Glisic, Branko [4 ]
Inaudi, Daniele [5 ]
Posenato, Daniele [5 ]
Yang-Zhao [6 ]
机构
[1] Univ Trento, DICAM, Via Mesiano 77, I-38050 Trento, Italy
[2] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
[3] Northeastern Univ, Boston, MA 02115 USA
[4] Princeton Univ, Princeton, NJ 08544 USA
[5] Smartec SA, CH-6928 Manno, Switzerland
[6] Intelligent Instrument Syst, Burr Ridge, IL USA
来源
关键词
Bayesian inference; fiber optic sensors; elasto-magnetic sensors; Cable-Stayed bridge;
D O I
10.4028/www.scientific.net/KEM.569-570.812
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper illustrates an application of Bayesian logic to monitoring data analysis and structural condition state inference. The case study is a 260 m long cable-stayed bridge spanning the Adige River 10 km north of the town of Trento, Italy. This is a statically indeterminate structure, having a composite steel-concrete deck, supported by 12 stay cables. Structural redundancy, possible relaxation losses and an as-built condition differing from design, suggest that long-term load redistribution between cables can be expected. To monitor load redistribution, the owner decided to install a monitoring system which combines built-on-site elasto-magnetic and fiber-optic sensors. In this note, we discuss a rational way to improve the accuracy of the load estimate from the EM sensors taking advantage of the FOS information. More specifically, we use a multi-sensor Bayesian data fusion approach which combines the information from the two sensing systems with the prior knowledge, including design information and the outcomes of laboratory calibration. Using the data acquired to date, we demonstrate that combining the two measurements allows a more accurate estimate of the cable load, to better than 50 kN
引用
收藏
页码:812 / +
页数:2
相关论文
共 50 条
  • [21] Structural health monitoring of a cable-stayed bridge with Bayesian neural networks
    Arangio, Stefania
    Bontempi, Franco
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2015, 11 (04) : 575 - 587
  • [22] Application of Wireless Monitoring System to Structural Health Monitoring of Long-Spanned Cable-Stayed Bridge
    孟庆成
    齐欣
    李乔
    Journal of Southwest Jiaotong University(English Edition), 2007, (02) : 117 - 121
  • [23] Investigation concerning structural health monitoring of an instrumented cable-stayed bridge
    Ko, J. M.
    Ni, Y. Q.
    Zhou, H. F.
    Wang, J. Y.
    Zhou, X. T.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2009, 5 (06) : 497 - 513
  • [24] HEALTH MONITORING AND EVALUATION SYSTEM FOR CABLE-STAYED BRIDGE USING COMPUTATIONAL SIMULATION AND SENSOR DATA
    Xie, Haibo
    Tian, Zhongchu
    Zheng, Wanggang
    Zhou, Yuxiang
    INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 185 - 188
  • [25] Modal Analysis of a Cable-stayed Bridge
    Wei, Liuchuang
    Cheng, Heming
    Li, Jianyun
    INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTATIONAL MODELING AND SIMULATION, 2012, 31 : 481 - 486
  • [26] The Structural Form and Development of Cable-Stayed Bridge
    Yu, BaoChu
    Wang, JiaSong
    Ai, Jie
    Sun, RongYang
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS, MECHATRONICS AND CIVIL ENGINEERING (ICAMMCE 2017), 2017, 121 : 61 - 64
  • [27] Modular Sensor for Detecting Cable Faults of Cable-Stayed Bridge
    Xie Qi
    Xu Fengyu
    Wang Xingsong
    2008 15TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE (M2VIP), 2008, : 35 - 39
  • [28] Correlation analysis of the wind of a cable-stayed bridge based on field monitoring
    Li H.
    Laima S.
    Li N.
    Ou J.
    Duan Z.
    Wind and Structures, An International Journal, 2010, 13 (06): : 529 - 556
  • [29] Dynamic response for structural health monitoring of the Penang (I) cable-stayed bridge
    Mohammed, M. I.
    Sulaeman, E.
    Mustapha, F.
    3RD INTERNATIONAL CONFERENCE ON MECHANICAL, AUTOMOTIVE AND AEROSPACE ENGINEERING 2016, 2017, 184
  • [30] Inspection, Structural Health Monitoring and Maintenance of a Cable-Stayed Bridge in Vienna, Austria
    Furtner, P.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 2552 - 2557