Biomechanical Evaluation of Stress Distribution in Subcrestal Placed Platform-switched Short Dental Implants in D4 Bone: In Vitro Finite-element Model Study

被引:7
|
作者
Sesha, Manchala R. [1 ]
Sunduram, Rajashekar [2 ]
Abdelmagyd, Hossam A. Eid [1 ]
机构
[1] Gulf Med Univ, Coll Dent, Dept Periodont, Ajman 4184, U Arab Emirates
[2] Rajah Muthiah Dent Coll & Hosp, Dept Periodont, Annamalainagar, Tamil Nadu, India
关键词
FEM; subcrestal; equicrestal; platform switched implants; short implants; DIAMETER; LENGTH; METAANALYSIS; SURVIVAL; DESIGNS;
D O I
10.4103/jpbs.JPBS_44_20
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The present study was carried out to assess stress distribution in the maxillary posterior bone region (D4 bone) with the help of a short platform switched subcrestal dental implants using the FEM model. Missing teeth surfaces related to the maxillary posterior region were stimulated. The bone model had a cancellous core of (0.5 mm) which represents D4 bone. A 7.5x4.6 mm screw type implant system with 3.5 platform switch abutment was selected. ANSYS WORKBENCH was used to model all the finite element structures. Force of 100 N was tested and adapted at an angle of 0o, 15o, 30o on the tooth model. Overall results from the current study showed that a high amount of stress was seen in cortical than in relation to cancellous bone. Stress values reduced from equicrestal to subcrestal (2 mm) placement of dental implants irrespective of angulation of load from 0o to 30o in both types of bone. However higher stress values were seen when force was applied in an oblique direction (30o) in comparison to a vertical load (0o). Least amount of stress was noticed when platform switched implants were placed 0.5 mm subcrestatlly irrespective of angulations of a load. Platform switched short subcrestal implants reduced the stress in the D4 cortical bone than in contrary equicrestal implant placement. This results in the preservation of marginal bone leading to implant success.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 27 条
  • [1] Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
    Ellendula, Yashaswini
    Sekar, Anam Chandra
    Nalla, Sandeep
    Basany, Ram B.
    Sailasri, Kunchala
    Thandu, Ashwini
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
  • [2] Finite-element study of biomechanical explanations for bone loss around dental implants
    Merdji A.
    Taharou B.
    Hillstrom R.
    Benaissa A.
    Roy S.
    Chong P.L.
    Mukdadi O.
    Della N.
    Bouiadjra B.-A.B.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (01) : 21 - 30
  • [3] Soft Tissue and Crestal Bone Changes Around Implants with Platform-Switched Abutments Placed Nonsubmerged at Subcrestal Position: A 2-Year Clinical and Radiographic Evaluation
    Aimetti, Mario
    Ferrarotti, Francesco
    Mariani, Giulia Maria
    Ghelardoni, Carlo
    Romano, Federica
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (06) : 1369 - 1377
  • [4] Evaluating the effect of subcrestal placement on platform switched short dental implants and von mises stress in D3 bone-A 3D FEM study
    Reddy, M. S.
    Rajasekar, S.
    Eid Abdelmagyd, H. A.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (05) : 660 - 666
  • [5] Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis
    Ali Robaian Alqahtani
    Shrikar R. Desai
    Jignesh R. Patel
    Nasser Raqe Alqhtani
    Abdullah Saad Alqahtani
    Artak Heboyan
    Gustavo V. O. Fernandes
    Mohammed Mustafa
    Mohamed Isaqali Karobari
    BMC Oral Health, 23
  • [6] Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis
    Alqahtani, Ali Robaian
    Desai, Shrikar R.
    Patel, Jignesh R.
    Alqhtani, Nasser Raqe
    Alqahtani, Abdullah Saad
    Heboyan, Artak
    Fernandes, Gustavo V. O.
    Mustafa, Mohammed
    Karobari, Mohamed Isaqali
    BMC ORAL HEALTH, 2023, 23 (01)
  • [7] Evaluation of the Peri-Implant Bone Level around Platform-Switched Dental Implants: A Retrospective 3-Year Radiographic Study
    Pan, Yu Hwa
    Lin, His Kuei
    Lin, Jerry C-Y
    Hsu, Yung-Szu
    Wu, Yi-Fan
    Salamanca, Eisner
    Chang, Wei-Jen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (14)
  • [8] Comparison of Stress Distribution Among Standard Dental Implants Placed in Grafted Bone, Zygomatic Implants, and Subperiosteal Implants in the Atrophic Edentulous Maxilla: 3D Finite Element Analysis
    Keles, H. Gozde
    Karaca, Cigdem
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 347 - 356
  • [9] The evaluation of stress on bone level and tissue level short implants: A Finite Element Analysis (FEA) study
    Avag, Canseda
    Akkocaoglu, Murat
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [10] Finite element analysis of stress distribution around a dental implant with different amounts of bone loss: An in vitro study
    Jafarian, Mohammad
    Mirhashemi, Fatemeh Sadat
    Emadi, Naghmeh
    DENTAL AND MEDICAL PROBLEMS, 2019, 56 (01) : 27 - 32