Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis

被引:12
|
作者
Alqahtani, Ali Robaian [1 ]
Desai, Shrikar R. [2 ]
Patel, Jignesh R. [3 ]
Alqhtani, Nasser Raqe [4 ]
Alqahtani, Abdullah Saad [5 ]
Heboyan, Artak [6 ]
Fernandes, Gustavo V. O. [7 ]
Mustafa, Mohammed [1 ]
Karobari, Mohamed Isaqali [8 ,9 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Dent, Dept Conservat Dent Sci, Al Kharj 11942, Saudi Arabia
[2] HKES S Nijalingappa Inst Dent Sci & Res, Dept Periodontol & Implantol, Kalaburagi 585105, India
[3] Dr Patels Specialty Dent Care, 203 Silver Empire,Opposite Utran Power House Gate, Surat 394107, India
[4] Prince Sattam Bin Abdulaziz Univ, Dept Oral & Maxillofacial Surg & Diagnost Sci, Coll Dent, Al Kharj 11942, Saudi Arabia
[5] Prince Sattam Bin Abdulaziz Univ, Coll Dent, Dept Prevent Dent Sci, Al Kharj 11942, Saudi Arabia
[6] Yerevan State Med Univ, Fac Stomatol, Dept Prosthodont, Str Koryun 2, Yerevan 0025, Armenia
[7] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[8] Univ Puthisastra, Fac Dent, Dept Restorat Dent & Endodont, Phnom Penh 12211, Cambodia
[9] Saveetha Univ, Saveetha Inst Med & Tech Sci, Saveetha Med Coll & Hosp, Ctr Global Hlth Res, Kuthambakkam, India
关键词
Bone quality; Immediate loading; Platform switched; Short implant; SHORT DENTAL IMPLANTS; STRESS-DISTRIBUTION; SURROUNDING BONE; ALVEOLAR CREST; LENGTH; QUALITY; DENTISTRY; SMOOTH; 3-YEAR; LEVEL;
D O I
10.1186/s12903-023-03370-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundDental implants emerge as a dependable and efficacious alternative for patients experiencing partial or complete tooth loss. The stability of these implants is influenced by surface topography and macro-level design. In cases where the height of the maxillary posterior region is diminished, employing short implants can prove advantageous. With the aim of examining the distribution of von Mises stress, strain, and micromovement in D4 bone quality surrounding platform-switched short implants, measuring 6 mm in length and featuring diameters ranging from 4 to 6 mm, as well as different thread designs, an in-depth finite element analysis was conducted under immediate loading conditions.MethodologyA 3D finite element model was constructed to simulate maxillary molar crowns, incorporating an implant with a length of 6 mm and varying diameters and thread designs. The diameters utilized were 4/3.6 mm, 5/4 mm, and 6/4.8 mm, while the thread designs included buttress, square, and triangle patterns. Each model underwent analysis with a 100 N force applied in two directions: vertical and oblique, relative to the long axis of the implant. Stress, strain, and micromovement in the peri-implant region were recorded, employing the Ansys Workbench R v.18.1 software for modelling and analysis.ResultsWhen comparing all three diameters, the wide diameter (6 mm threads) exhibited the lowest values of peri-implant von Mises stresses (3.3 MPa and 35.1 MPa), strains (194 & sigma; and 484 & sigma;), and micromovements (0.7 & mu;m and 1.3 & sigma;) subjected to axial and non-axial loading of a 100 N force. Notably, square microthreads yielded the most favorable stress parameters among the different thread shapes, manifesting the minimum values of stress, strains, and micromovements in their vicinity.ConclusionFor the treatment of atrophic ridges or in scenarios necessitating extensive surgical preparation of the implant site, a combination of short implants, wide diameters, and platform switching can be employed. In situations with reduced bone height and the requirement for an implant-supported prosthesis to replace a missing permanent maxillary molar, the utilization of wide-diameter platform-switched short implants measuring 6 mm in length, featuring a square thread design, should be taken into consideration.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis
    Ali Robaian Alqahtani
    Shrikar R. Desai
    Jignesh R. Patel
    Nasser Raqe Alqhtani
    Abdullah Saad Alqahtani
    Artak Heboyan
    Gustavo V. O. Fernandes
    Mohammed Mustafa
    Mohamed Isaqali Karobari
    BMC Oral Health, 23
  • [2] A 3D Finite Element Analysis Of Dental Implants With Varying Thread Angles
    NarendraKumar, U.
    Mathew, Arun Tom
    Iyer, Nikhil
    Rahman, Febin
    Manjubala, I.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (05) : 11900 - 11905
  • [3] Biomechanical Evaluation of Stress Distribution in Subcrestal Placed Platform-switched Short Dental Implants in D4 Bone: In Vitro Finite-element Model Study
    Sesha, Manchala R.
    Sunduram, Rajashekar
    Abdelmagyd, Hossam A. Eid
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 134 - 139
  • [4] Comparison of Stress Distribution Among Standard Dental Implants Placed in Grafted Bone, Zygomatic Implants, and Subperiosteal Implants in the Atrophic Edentulous Maxilla: 3D Finite Element Analysis
    Keles, H. Gozde
    Karaca, Cigdem
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 347 - 356
  • [5] 3D imaging and biomechanics: Bringing 3D finite element modeling to comparative biology
    Dumont, Elizabeth
    Werle, Sean
    Grosse, Ian
    JOURNAL OF VERTEBRATE PALEONTOLOGY, 2006, 26 (03) : 57A - 57A
  • [6] Effect of vertical bone loss on stress distribution at the bone-implant interface around implants of varying diameters-an in silico 3D finite element analysis
    Gupta, Shipra
    Chopra, Priyanka
    Goyal, Parveen
    Jain, Ashish
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 4581 - 4586
  • [7] Investigation of stress distribution in implant thread design: A 3D Finite Element Analysis
    Jackson Irudhayam, S.
    Hariram, V.
    Materials Today: Proceedings, 2021,
  • [8] Stress analysis in bone tissue around single implants with different diameters and veneering materials: A 3-D finite element study
    Santiago Junior, Joel Ferreira
    Pellizzer, Eduardo Piza
    Verri, Fellippo Ramos
    Perri de Carvalho, Paulo Sergio
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08): : 4700 - 4714
  • [9] Stress Distribution Pattern in Mandibular Overdenture Designs Supported by Three Dental Implants: A 3D Finite Element Analysis
    Aminianpour, Negin
    Alikhasi, Marzieh
    Kasari, Mostafa Shabanpour
    Yousefi, Hashem
    Siadat, Hakimeh
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2025, 11 (01):
  • [10] Effects of all-on-four implant designs in mandible on implants and the surrounding bone: A 3-D finite element analysis
    Deste, G.
    Durkan, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (04) : 456 - 463