Sinogram affirmed iterative reconstruction in head CT: Improvement of objective and subjective image quality with concomitant radiation dose reduction

被引:43
|
作者
Korn, A. [1 ]
Bender, B. [1 ]
Fenchel, M. [1 ]
Spira, D. [2 ]
Schabel, C. [2 ]
Thomas, C. [2 ]
Flohr, T. [3 ]
Claussen, C. D. [2 ]
Bhadelia, R. [4 ]
Ernemann, U. [1 ]
Brodoefel, H. [2 ,4 ]
机构
[1] Dept Diagnost & Intervent Neuroradiol, D-72076 Tubingen, Germany
[2] Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Siemens HealthCare, Computed Tomog Div, D-91301 Forchheim, Germany
[4] Beth Israel Deaconess Med Ctr, Boston, MA 02115 USA
关键词
Head CT; Iterative reconstruction; Image quality; FILTERED BACK-PROJECTION; ART;
D O I
10.1016/j.ejrad.2013.03.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Iterative reconstruction has recently been revisited as a promising concept for substantial CT dose reduction. The purpose of this study was to assess the potential benefit of sinogram affirmed iterative reconstruction (SAFIRE) in head CT by comparing objective and subjective image quality at reduced tube current with standard dose filtered back projection (FBP). Materials and methods: Non-contrast reduced dose head CT (255 mA s, CTDIvol 47.8 mGy) was performed in thirty consecutive patients and reconstructed with SAFIRE and FBP. Images were assessed in terms of quantitative and qualitative image quality and compared with FBP of standard dose acquisitions (320 mA s, CTDIvol 59.7 mGy). Results: In reduced dose CT examinations, use of SAFIRE versus FBP resulted in 47% increase in contrast-to-noise ratio (CNR) (2.49 vs. 1.69; p<0.0001). While reduction of tube current was associated with 13% decrease in CNR, quantitative degradation of image quality at lower dose was more than compensated through SAFIRE (2.49 vs. 1.96; p = 0.0004). Objective measurements of image sharpness were comparable between FBP and SAFIRE reconstructions (575.9 +/- 74.1 vs. 583.4 +/- 74.7 change in HU/Pixel; p = 0.28). Compared to standard dose FBP, subjective grading of noise as well as overall image quality scores were significantly improved when SAFIRE was used in reduced dose exams (1.3 vs. 1.6, p = 0.006; 1.3 vs. 1.7, p = 0.026). Conclusion: At 20% dose reduction, reconstruction of head CT by SAFIRE provides above standard objective and subjective image quality, suggesting potential for more vigorous dose savings in neuroradiology CT applications. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1431 / 1435
页数:5
相关论文
共 50 条
  • [21] Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography
    Guo Zhong Chen
    Long Jiang Zhang
    U. Joseph Schoepf
    Julian L. Wichmann
    Cole M. Milliken
    Chang Sheng Zhou
    Li Qi
    Song Luo
    Guang Ming Lu
    [J]. European Radiology, 2015, 25 : 1453 - 1463
  • [22] Ultra-low dose CT colonography with automatic tube current modulation and sinogram-affirmed iterative reconstruction: Effects on radiation exposure and image quality
    Cianci, Roberta
    Pizzi, Andrea Delli
    Esposito, Gianliugi
    Timpani, Mauro
    Tavoletta, Alessandra
    Pulsone, Pierluigi
    Basilico, Raffaella
    Cotroneo, Antonio Raffaele
    Filippone, Antonella
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 321 - 330
  • [23] Radiation dose reduction using 100-kVp and a sinogram-affirmed iterative reconstruction algorithm in adolescent head CT: Impact on grey-white matter contrast and image noise
    Nagayama, Yasunori
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Yuki, Hideaki
    Hirarta, Kenichiro
    Kidoh, Masafumi
    Oda, Seitaro
    Utsunomiya, Daisuke
    Yamashita, Yasuyuki
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (07) : 2717 - 2725
  • [24] Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose
    Song, Inyoung
    Yi, Jeong Geun
    Park, Jeong Hee
    Ko, Sung Min
    [J]. PLOS ONE, 2016, 11 (09):
  • [25] Influence of Sinogram Affirmed Iterative Reconstruction of CT Data on Image Noise Characteristics and Low-Contrast Detectability: An Objective Approach
    von Falck, Christian
    Bratanova, Vesela
    Rodt, Thomas
    Meyer, Bernhard
    Waldeck, Stephan
    Wacker, Frank
    Shin, Hoen-oh
    [J]. PLOS ONE, 2013, 8 (02):
  • [26] CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection
    Wang, R.
    Schoepf, U. J.
    Wu, R.
    Gibbs, K. P.
    Yu, W.
    Li, M.
    Zhang, Z.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (03) : 272 - 278
  • [27] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [28] CT angiography of the aorta using 80kVp in combination with sinogram-affirmed iterative reconstruction and automated tube current modulation: Effects on image quality and radiation dose
    Boos, Johannes
    Aissa, Joel
    Lanzman, Rotem S.
    Heusch, Philipp
    Schimmoeller, Lars
    Schleich, Christoph
    Thomas, Christoph
    Antoch, Gerald
    Kroepil, Patric
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (02) : 187 - 193
  • [29] High-pitch Dual-source Computed Tomography Coupled with Sinogram-affirmed Iterative Reconstruction: Image Quality and Radiation Dose in Children
    Lee, J. C. Y.
    Tse, K. S.
    Lau, H. Y.
    Fok, W. S.
    Chan, K. K.
    Chat, W. H.
    Yung, W. K.
    Mui, T. M.
    [J]. HONG KONG JOURNAL OF RADIOLOGY, 2018, 21 (01): : 40 - 47
  • [30] Low-dose CT for patients with clinically suspected acute appendicitis: optimal strength of sinogram affirmed iterative reconstruction for image quality and diagnostic performance
    Kim, Seung Ho
    Yoon, Jung-Hee
    Lee, Jang Hee
    Lim, Yun-Jung
    Kim, Ok Hwa
    Ryu, Ji Hwa
    Son, Jung-Hee
    [J]. ACTA RADIOLOGICA, 2015, 56 (08) : 899 - 907