Image registration of ex-vivo MRI to sparsely sectioned histology of hippocampal and neocortical temporal lobe specimens

被引:33
|
作者
Goubran, Maged [1 ,3 ]
Crukley, Cathie [1 ]
de Ribaupierre, Sandrine [2 ,3 ]
Peters, Terence M. [1 ,3 ,4 ]
Khan, Ali R. [1 ,4 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Clin Neurol Sci, London, ON, Canada
[3] Univ Western Ontario, London, ON, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Image registration; MRI; Histology; Epilepsy; Anterior temporal lobectomy; CO-REGISTRATION; EPILEPSY; BRAIN; HISTOPATHOLOGY; RECONSTRUCTION; DEFORMATIONS; SLICES;
D O I
10.1016/j.neuroimage.2013.07.053
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Intractable or drug-resistant epilepsy occurs in up to 30% of epilepsy patients, with many of these patients undergoing surgical excision of the affected brain region to achieve seizure control. Recent magnetic resonance imaging (MRI) sequences and analysis techniques have the potential to detect abnormalities not identified with diagnostic MRI protocols. Prospective studies involving pre-operative imaging and collection of surgically-resected tissue provide a unique opportunity for verification and tuning of these image analysis techniques, since direct comparison can be made against histopathology, and can lead to better prediction of surgical outcomes and potentially less invasive procedures. To carry out MRI and histology comparison, spatial correspondence between the MR images and the histology images must be found. Towards this goal, a novel pipeline is presented here for bringing ex-vivo MRI of surgically-resected temporal lobe specimens and digital histology into spatial correspondence. The sparsely-sectioned histology images represent a challenge for 3D reconstruction which we address with a combined 3D and 2D registration algorithm that alternates between slice-based and volume-based registration with the ex-vivo MRI. We evaluated our registration method on specimens resected from patients undergoing anterior temporal lobectomy (N = 7) and found our method to have a mean target registration error of 0.76 +/- 0.66 and 0.98 +/- 0.60 mm for hippocampal and neocortical specimens respectively. This work allows for the spatially-local comparison of histology with post-operative MRI and paves the way for eventual correlation with pre-operative MM image analysis techniques. (C) 2013 Elsevier Inc All rights reserved.
引用
下载
收藏
页码:770 / 781
页数:12
相关论文
共 29 条
  • [21] Ex vivo MRI atlas of the human medial temporal lobe: characterizing neurodegeneration due to tau pathology
    Ravikumar, Sadhana
    Wisse, Laura E. M.
    Lim, Sydney
    Ittyerah, Ranjit
    Xie, Long
    Bedard, Madigan L.
    Das, Sandhitsu R.
    Lee, Edward B.
    Tisdall, M. Dylan
    Prabhakaran, Karthik
    Lane, Jacqueline
    Detre, John A.
    Mizsei, Gabor
    Trojanowski, John Q.
    Robinson, John L.
    Schuck, Theresa
    Grossman, Murray
    Artacho-Perula, Emilio
    de Onzono Martin, Maria Mercedes Iniguez
    Arroyo Jimenez, Maria Del Mar
    Munoz, Monica
    Molina Romero, Francisco Javier
    Marcos Rabal, Maria Del Pilar
    Cebada Sanchez, Sandra
    Delgado Gonzalez, Jose Carlos
    Rosa Prieto, Carlos de la
    Corcoles Parada, Marta
    Irwin, David J.
    Wolk, David A.
    Insausti, Ricardo
    Yushkevich, Paul A.
    ACTA NEUROPATHOLOGICA COMMUNICATIONS, 2021, 9 (01):
  • [22] Ex vivo MRI atlas of the human medial temporal lobe: characterizing neurodegeneration due to tau pathology
    Sadhana Ravikumar
    Laura E. M. Wisse
    Sydney Lim
    Ranjit Ittyerah
    Long Xie
    Madigan L. Bedard
    Sandhitsu R. Das
    Edward B. Lee
    M. Dylan Tisdall
    Karthik Prabhakaran
    Jacqueline Lane
    John A. Detre
    Gabor Mizsei
    John Q. Trojanowski
    John L. Robinson
    Theresa Schuck
    Murray Grossman
    Emilio Artacho-Pérula
    Maria Mercedes Iñiguez de Onzoño Martin
    María del Mar Arroyo Jiménez
    Monica Muñoz
    Francisco Javier Molina Romero
    Maria del Pilar Marcos Rabal
    Sandra Cebada Sánchez
    José Carlos Delgado González
    Carlos de la Rosa Prieto
    Marta Córcoles Parada
    David J. Irwin
    David A. Wolk
    Ricardo Insausti
    Paul A. Yushkevich
    Acta Neuropathologica Communications, 9
  • [23] Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology
    van Engelen, Arna
    Niessen, Wiro J.
    Klein, Stefan
    Groen, Harald C.
    Verhagen, Hence J. M.
    Wentzel, Jolanda J.
    van der Lugt, Aad
    de Bruijne, Marleen
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 241 - 256
  • [24] Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology
    Rieber, Johannes
    Meissner, Oliver
    Babaryka, Gregor
    Reim, Susanne
    Oswald, Melanie
    Koenig, Andreas
    Schiele, Thomas M.
    Shapiro, Michael
    Theisen, Karl
    Reiser, Maximilian F.
    Klauss, Volker
    Hoffmann, Udo
    CORONARY ARTERY DISEASE, 2006, 17 (05) : 425 - 430
  • [25] Facilitating Tumor Functional Assessment by Spatially Relating 3D Tumor Histology and In Vivo MRI: Image Registration Approach
    Alic, Lejla
    Haeck, Joost C.
    Bol, Karin
    Klein, Stefan
    van Tiel, Sandra T.
    Wielepolski, Piotr A.
    de Jong, Marion
    Niessen, Wiro J.
    Bernsen, Monique
    Veenland, Jifke F.
    PLOS ONE, 2011, 6 (08):
  • [26] Optimal contrast-enhanced MRI image thresholding for accurate prediction of ventricular tachycardia using ex-vivo high resolution models
    Deng, Dongdong
    Nikolov, Plamen
    Arevalo, Hermenegild J.
    Trayanova, Natalia A.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 102 : 426 - 432
  • [27] 7-T MRI of explanted liver and ex-vivo pancreatic specimens: prospective study protocol of radiological-pathological correlation feasibility (the EXLIPSE project)
    Cervelli, Rosa
    Cencini, Matteo
    Buonincontri, Guido
    Campana, Francesco
    Insilla, Andrea Cacciato
    Aringhieri, Giacomo
    De Simone, Paolo
    Boggi, Ugo
    Campani, Daniela
    Tosetti, Michela
    Crocetti, Laura
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [28] 7-T MRI of explanted liver and ex-vivo pancreatic specimens: prospective study protocol of radiological-pathological correlation feasibility (the EXLIPSE project)
    Rosa Cervelli
    Matteo Cencini
    Guido Buonincontri
    Francesco Campana
    Andrea Cacciato Insilla
    Giacomo Aringhieri
    Paolo De Simone
    Ugo Boggi
    Daniela Campani
    Michela Tosetti
    Laura Crocetti
    European Radiology Experimental, 4
  • [29] 4D Lung Imaging with Time-resolved 3D MRI: Comparison of Different Sequence Parameters for the Assessment of Tumor Size and Image Quality in a Ventilated Ex-vivo Setup
    Dinkel, J.
    Tetzlaff, R.
    Hintze, C.
    Thieke, C.
    Rochet, N.
    Delorme, S.
    Biederer, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S145 - S146