Snapshot-imaging motional Stark effect polarimetry

被引:23
|
作者
Howard, John [1 ]
机构
[1] Australian Natl Univ, Plasma Res Lab, Canberra, ACT 0200, Australia
关键词
D O I
10.1088/0741-3335/50/12/125003
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Measurement of the motional Stark effect (MSE) for Balmer alpha light emitted from heating or diagnostic neutral beams is a standard technique for estimating plasma toroidal current density in tokamaks. Most techniques typically rely on a determination of the polarization angle or relative intensities of the multiplet components which are spectrally resolved using either an array of interference filters or a high-throughput grating instrument. Neither of these approaches is amenable to two-dimensional MSE imaging. This paper proposes an alternative measurement scheme that is suitable for single snapshot two-dimensional imaging of the current distribution. This is achieved using a spectro-polarimeter that encodes the polarization and spectral information upon spatially orthogonal linear interference fringe patterns illuminated by the image of the Stark-shifted H-alpha emission from the neutral beam. The new technique opens the possibility to use synchronous detection methods and gated cameras to resolve the magnetic structure of periodic tokamak phenomena including sawteeth and magnetohydrodynamic activity.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Ab initio modeling of the motional Stark effect on MAST
    De Bock, M. F. M.
    Conway, N. J.
    Walsh, M. J.
    Carolan, P. G.
    Hawkes, N. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [42] Improved spectral analysis for the motional Stark effect diagnostic
    Ko, J.
    Klabacha, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [43] Feasibility of a motional Stark effect system on the TCV tokamak
    Siegrist, MR
    Hawkes, N
    Weisen, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3465 - 3467
  • [44] The Motional Stark Effect diagnostic at TEXTOR-94
    Elzendoorn, BSQ
    Jaspers, R
    FUSION ENGINEERING AND DESIGN, 2001, 56-57 : 953 - 957
  • [45] Active cancellation of the motional Stark effect in the diamagnetic spectrum of Ba
    Blackett Laboratory, Imperial College, London, SW7 2BZ, United Kingdom
    Journal of Physics B: Atomic, Molecular and Optical Physics, 1995, 28 (17):
  • [46] MOTIONAL STARK EFFECT IN THE LII AND NAI MAGNETIC RYDBERG SPECTRA
    CROSSWHITE, HM
    CROSSWHITE, H
    TOMKINS, FS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (03): : 476 - 476
  • [47] Digital lock-in technique for the motional Stark effect diagnostic
    Shi, YJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [48] CONSEQUENCE OF THE MOTIONAL STARK-EFFECT IN 2 PHOTON SPECTROSCOPY
    HARRIS, RA
    JOURNAL OF CHEMICAL PHYSICS, 1980, 72 (01): : 774 - 775
  • [49] MOTIONAL STARK-EFFECT UPGRADES ON DIII-D
    RICE, BW
    NILSON, DG
    WROBLEWSKI, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 373 - 375
  • [50] Calibration and operational experience with the JET motional Stark effect diagnostic
    Hawkes, N. C.
    Brix, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):