Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site

被引:32
|
作者
Fetter, JG
Benditt, DG
Stanton, MS
机构
[1] UNIV MINNESOTA,DEPT MED,CARDIAC ARRHYTHMIA CTR,MINNEAPOLIS,MN 55455
[2] MAYO CLIN,ROCHESTER,MN
关键词
D O I
10.1016/0735-1097(96)00147-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Background. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. Methods. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating are welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. Results. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequen cies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. Conclusions. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires similar to 10 G. Our testing at the work site revealed no electrical interference with this type of defibrillator. Patients were allowed to return to work, The following precautions should be observed by the patient: 1) maintain a minimal distance of 2 ft (61 cm) from the melding are and cables or large motors, 2) do not exceed tested currents with the welding equipment, 3) wear insulated gloves while operating electrical equipment, 4) verify that electrical equipment is properly grounded, and 5) stop welding and leave the work area immediately if a therapy is delivered or a feeling of lightheadedness is experienced.
引用
收藏
页码:423 / 427
页数:5
相关论文
共 50 条
  • [1] Electromagnetic Interference from Electric Vehicles: Implications for Subcutaneous Implantable Cardioverter-Defibrillators
    Salam, Kamil
    Salih, Anmar
    Goswami, Tarun
    Wase, Abdul
    CIRCULATION, 2024, 150
  • [2] Electromagnetic Interference With Implantable Cardioverter-Defibrillators at Power Frequency An In Vivo Study
    Napp, Andreas
    Joosten, Stephan
    Stunder, Dominik
    Knackstedt, Christian
    Zink, Matthias
    Bellmann, Barbara
    Marx, Nikolaus
    Schauerte, Patrick
    Silny, Jiri
    CIRCULATION, 2014, 129 (04) : 441 - 450
  • [3] Prediction of magnetic interference from resistance spot welding processes on implantable cardioverter-defibrillators
    Martin, Oscar
    Lopez, Manuel
    De Tiedra, Pilar
    Juan, Manuel San
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2008, 206 (1-3) : 256 - 262
  • [4] Electromagnetic interference from wireless video-capsule endoscopy on implantable cardioverter-defibrillators
    Dubner, Sergio
    Dubner, Yael
    Rubio, Horacio
    Goldin, Eran
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (04): : 472 - 475
  • [5] Exploring Electromagnetic Interference Between Pacemakers, Implantable Cardioverter-Defibrillators, and Capsule Endoscopy
    Fleming, Peter
    Lossen, Victoria
    Brown, Janine
    Lerner, Paul
    Verhoef, William
    Koppola, James
    Eddy, Steven
    Neuman, Stacey
    Herre, John
    Johnson, David
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 : S529 - S529
  • [6] Electromagnetic interference from left ventricular assist devices in patients with subcutaneous implantable cardioverter-defibrillators
    Ishida, Yuji
    Payne, Joshua E.
    Field, Michael E.
    Gold, Michael R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (05) : 1195 - 1201
  • [7] Electromagnetic interference from left ventricular assist devices detected in patients with implantable cardioverter-defibrillators
    Sheldon, Seth H.
    Jazayeri, Mohammad-Ali
    Pierpoline, Michael
    Mohammed, Moghniuddin
    Parikh, Valay
    Robinson, Alexander
    Noheria, Amit
    Haglund, Nicholas
    Sauer, Andrew J.
    Reddy, Y. Madhu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (01) : 93 - 101
  • [8] Interference of electrical dental equipment with implantable cardioverter-defibrillators
    H. S. Brand
    M. L. Entjes
    A. V. Nieuw Amerongen
    E. V. van der Hoeff
    T. A. M. Schrama
    British Dental Journal, 2007, 203 : 577 - 579
  • [9] Interference of electrical dental equipment with implantable cardioverter-defibrillators
    Brand, H. S.
    Entjes, M. L.
    Amerongen, A. V. Nieuw
    Van der Hoeff, E. V.
    Schrama, T. A. M.
    BRITISH DENTAL JOURNAL, 2007, 203 (10) : 577 - 579
  • [10] Electromagnetic interference with cardiac pacemakers and implantable cardioverter-defibrillators from low-frequency electromagnetic fields in vivo
    Tiikkaja, Maria
    Aro, Aapo L.
    Alanko, Tommi
    Lindholm, Harri
    Sistonen, Heli
    Hartikainen, Juha E. K.
    Toivonen, Lauri
    Juutilainen, Jukka
    Hietanen, Maila
    EUROPACE, 2013, 15 (03): : 388 - 394