Electrical emissions from concrete under three-point bending tests

被引:0
|
作者
Liu, QP [1 ]
Sun, MQ
Li, ZQ
Li, GQ
机构
[1] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Wuhan Univ Technol, Dept Engn Struct & Mech, Wuhan 430070, Peoples R China
关键词
cement and concrete; electrical emission; non-destruction test;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electrical emission (EM) signals, which are generated from the concrete specimens under three-point bending tests, were conducted. It is shown that electrical emission phenomena are related to cracking of the specimens, cohesive failure, contact-separation etc. The simultaneous appearance of electric emission signals and visible cracks during the flexure loading of beams was also observed.
引用
收藏
页码:102 / 104
页数:3
相关论文
共 50 条
  • [21] Electrical-mechanical behaviors of three-dimensional braided composites under three-point bending
    Huang, Wei
    Xue, Yousong
    Xue, Lingming
    Gu, Bohong
    Sun, Baozhong
    Zhang, Wei
    TEXTILE RESEARCH JOURNAL, 2023, 93 (3-4) : 713 - 725
  • [22] A compact bending device for in-situ three-point bending tests under laser scanning confocal microscope
    Jianping Li
    Hongwei Zhao
    Xiaoli Hu
    Lin Zhang
    Pengliang Hou
    Cong Li
    Ning Li
    Yuexi Zhong
    Changyi Liu
    Instruments and Experimental Techniques, 2016, 59 : 762 - 767
  • [23] Experimental and numerical analysis of a biodegradable hybrid composite under tensile and three-point bending tests
    Beigpour, Reza
    Shokrollahi, Hassan
    Khalili, S. Mohammad Reza
    COMPOSITE STRUCTURES, 2021, 273
  • [24] Test for crack opening displacement of steel fiber reinforced concrete under Three-Point Bending
    Zhang, Tingyi
    Leng, Yuanbao
    Gao, Danying
    PRECISION INSTRUMENTATION AND MEASUREMENT, 2010, 36 : 157 - +
  • [25] Fracture process zone in notched concrete beam under three-point bending by acoustic emission
    Ohno, Kentaro
    Uji, Kimitaka
    Ueno, Atsushi
    Ohtsu, Masayasu
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 67 : 139 - 145
  • [26] Opening displacement of steel fiber reinforced high strength concrete under three-point bending
    Zhang, Ting-Yi
    Gao, Dan-Ying
    Wang, Bao-Ting
    Shuili Xuebao/Journal of Hydraulic Engineering, 2010, 41 (10): : 1193 - 1200
  • [27] Fracture characteristics of steel fiber reinforced high strength concrete under three-point bending
    Research Center of New Style Building Material and Structure, Zhengzhou University, Zhengzhou 450002, China
    Kuei Suan Jen Hsueh Pao, 2007, 12 (1630-1635): : 1630 - 1635
  • [28] Size effects on the characteristics of fracture process zone of plain concrete under three-point bending
    Tang, Yuxiang
    Chen, Hongniao
    Xiao, Jianzhuang
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 315
  • [29] A method to solve tension softening relationship of concrete from the three-point bending test
    Department of Civil Engineering, Tsinghua University, Beijing 100084, China
    不详
    Kuei Suan Jen Hsueh Pao, 2007, 3 (268-274):
  • [30] Determination of stress intensity factor in concrete material under Brazilian disc and three-point bending tests using finite element method
    Benarbia, Djamila
    Benguediab, Mohamed
    Periodica Polytechnica Mechanical Engineering, 2015, 59 (04): : 199 - 203