Modelling of Switching Over-voltage on Ship Service Transformers

被引:0
|
作者
Hu, Lihua [1 ]
Butcher, Martin [1 ]
机构
[1] CONVERTEAM UK LTD, Rugby CV21 1BU, Warwick, England
关键词
Temporary over-voltage; Marine; On-board network; Transformer; Modelling;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Switching over-voltages are a normal phenomenon when a transformer is energized. This transient is experienced when switching a service or propulsion transformer on board a ship. Under some special circumstances, the over-voltage levels experienced by the transformers may be exacerbated by system interactions and can exceed the insulation levels of the transformer, leading to damage of the windings. The phenomenon of transient over-voltages during the switching of an HV/LV ship's service transformer is analyzed in this paper. The system conditions which lead to these worst case switching over-voltages are summarized below. A combination of factors can cause the worst case switching over-voltage condition, these are: Travelling switching wave and reflections; Re-strikes of vacuum circuit breakers; Saturation of the transformer which may inversely charge the power cable; A load characteristic that causes current surge at the switching instant inversely charging the cable. It is very difficult to model the vacuum circuit breaker and its switching transient accurately, because there are a number of random and unpredictable factors which impact greatly on the switching process and dynamics. A simplified model has been developed, based on the detailed description of the characteristics of the vacuum circuit breakers (VCBs) Ref[1], to simulate the switching over-voltages. This model is then used to investigate some of the parameters associated with the worst case switching over-voltages. The main conclusions reached from this work are: The simplified model is sufficient to model predict the transient over-voltages following the switching of a transformer. The worst case over-voltage could reach levels as high as 5.0 pu; Damping filters or commercially available equipment such as a ZORC (Zinc Oxide Resistor Capacitor) suppressor, can be used to control the over-voltages to more moderate and acceptable levels, at approximately 2.0 pu.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Experimental demonstration of an anode voltage sensor for high voltage IGBT over-voltage protection
    Caramel, C.
    Flores, D.
    Hidalgo, S.
    Legal, J.
    Austin, P.
    Imbernon, E.
    Rebollo, J.
    Sanchez, J. L.
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2010, 25 (11)
  • [42] Influence of Switching Conditions on Very Fast Transient Over-voltage in 500kV Gas Insulated Substation
    Liu, Qing
    Zhang, Yufeng
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4451 - 4454
  • [43] Stability of over-voltage diode characteristics in exploitation conditions
    Vujisic, M.
    Osmokrovic, P.
    Stankovic, K.
    Loncar, B.
    2007 IEEE PULSED POWER CONFERENCE, VOLS 1-4, 2007, : 1215 - +
  • [44] Simulation of resonance over-voltage during energization of high voltage power network
    Cheng, CP
    Chen, SH
    ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (08) : 650 - 654
  • [45] Transient Over-Voltage Protection in Distributed Generators Systems
    Qaisieh, Lauren M.
    Marar, Hazem W.
    2016 THE 4TH IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE), 2016, : 1 - 5
  • [46] Impact of distributed generators on distribution network over-voltage
    Zhejiang University, Hangzhou 310027, China
    不详
    Dianli Xitong Zidonghue, 2007, 12 (50-54+85):
  • [47] Note on glasstone's discussion of over-voltage measurement
    Sand, HJS
    Weeks, EJ
    JOURNAL OF THE CHEMICAL SOCIETY, 1923, 123 : 2896 - 2901
  • [48] Characteristic Prediction of a Varistor in Over-Voltage Protection Application
    Nagatomo, Kohei
    Muslim, Muhammad Aziz
    Tamura, Hiroki
    Tanno, Koichi
    Wijono
    NEURAL INFORMATION PROCESSING (ICONIP 2014), PT II, 2014, 8835 : 565 - 572
  • [50] Aging of the over-voltage protection elements caused by over-voltages
    Osmokrovic, P
    Loncar, B
    Stankovic, S
    Vasic, A
    MICROELECTRONICS RELIABILITY, 2002, 42 (12) : 1959 - 1966