Specific Heat Capacity at Constant Pressure of Ethanol by Flow Calorimetry

被引:16
|
作者
Miyazawa, Taishi [1 ]
Kondo, Satoshi [1 ]
Suzuki, Takuya [2 ]
Sato, Haruki [3 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] Keio Univ, Former Grad Sch Sci & Technol, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[3] Keio Univ, Dept Syst Design Engn, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
来源
关键词
LIQUID; HCFC-123; METHYL; ETHYL;
D O I
10.1021/je2013473
中图分类号
O414.1 [热力学];
学科分类号
摘要
Specific heat capacities at a constant pressure of liquid ethanol in a temperature range from (265 to 348) K at a pressure of 500 kPa were measured by using flow calorimetry. The expanded uncertainty evaluated is from (0.55 to 0.89) % including the repeatability. Existing measurements by other researchers and derived specific heat capacity values from the existing equation of state provide greater values beyond the uncertainty. To confirm the reliability of our measurements, we measured the heat capacities under the same conditions for different liquid ethanol samples provided from different manufacturers. The measurements almost perfectly agree each other. The measurements obtained for two different samples of liquid ethanol are reported.
引用
收藏
页码:1700 / 1707
页数:8
相关论文
共 50 条
  • [1] Blackbody heat capacity at constant pressure
    Moreira Jr, E. S.
    JOURNAL OF STATISTICAL MECHANICS-THEORY AND EXPERIMENT, 2024, 2024 (06):
  • [2] Heat Capacity Measurement by Flow Calorimetry: An Exact Analysis
    Hei, T. K.
    Raal, J. D.
    AICHE JOURNAL, 2009, 55 (01) : 206 - 216
  • [3] Experimental study on isobaric specific heat capacity of subcritical and supercritical fluids using flow calorimetry
    Han R.
    Yang Z.
    Yang S.
    Zhang B.
    Measurement: Sensors, 2020, 10-12
  • [4] Modeling the heat flow and heat capacity of modulated differential scanning calorimetry
    Wunderlich, B
    JOURNAL OF THERMAL ANALYSIS, 1997, 48 (02): : 207 - 224
  • [5] Modeling the heat flow and heat capacity of modulated differential scanning calorimetry
    B. Wunderlich
    Journal of thermal analysis, 1997, 48 : 207 - 224
  • [6] Heat capacity calorimetry
    J. Boerio-Goates
    R. Stevens
    B. Lang
    B. F. Woodfield
    Journal of Thermal Analysis and Calorimetry, 2002, 69 (3) : 773 - 783
  • [7] An Apparatus for Specific Heat Capacity Measurement by Thermal Radiation Calorimetry
    K. Morimoto
    S. Sawai
    K. Hisano
    International Journal of Thermophysics, 1999, 20 : 709 - 719
  • [8] An apparatus for specific heat capacity measurement by thermal radiation calorimetry
    Morimoto, K
    Sawai, S
    Hisano, K
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1999, 20 (02) : 709 - 719
  • [9] Specific heat capacity measurement at high temperature by thermal radiation calorimetry
    Morimoto, K
    Sawai, S
    Hisanno, K
    ICMMT'98: 1998 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 1998, : 249 - 252
  • [10] SPECIFIC-HEAT CAPACITY OF LENTIL SEEDS BY DIFFERENTIAL SCANNING CALORIMETRY
    TANG, J
    SOKHANSANJ, S
    YANNACOPOULOS, S
    KASAP, SO
    TRANSACTIONS OF THE ASAE, 1991, 34 (02): : 517 - 522