Storage phosphor and film-screen mammography:: performance with different mammographic techniques

被引:14
|
作者
Kheddache, S [1 ]
Thilander-Klang, A
Lanhede, B
Månsson, LG
Bjurstam, N
Ackerholm, P
Björneld, L
机构
[1] Univ Gothenburg, Sahlgrens Univ Hosp, Dept Diagnost Radiol, S-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrens Univ Hosp, Dept Radiat Phys, S-41345 Gothenburg, Sweden
关键词
digital radiography; storage phosphors; mammography; anthropomorphic phantom;
D O I
10.1007/s003300050716
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the image quality of storage phosphor plates with that in screen-film radiograms in mammography. Two anode/filter combinations were also compared - Mo/Mo and W/Rh. S Storage phosphor plates, generation IIIN (Fuji, Tokyo, Japan) and a conventional screen-film system (Kodak, Rochester, N. Y.) were evaluated using two mammographic units. One unit had a 0.6-mm focal spot, an anode/filter combination of Mo/Mo: and no grid (A(Mo)); the other had a 0.3-mm focal spot, a grid, and two possible combinations of anode/filter Mo/Mo (B-Mo) and W/Rh (B-W). Simulated tumours and microcalcifications were randomly positioned;in an anthropomorphic breast phantom (RMI model 165, no. 210-009, Radiation Measurements Inc., Middleton, Wisconsin). The image quality was evaluated using a modified version of receiver operating characteristics analysis. Five observers evaluated 300 films and 300 hard copy images each. Radiation doses were also determined. The image quality of the conventional screen-film images was significantly better than that for the storage phosphor plate mammograms. The B-Mo system rated best, for the detection of both tumours and microcalcifications,: all;:hough it was not significantly different from the Bw system. Systems B-Mo and B-W rated significantly better than the A(Mo) system for both image receptors studied. The mean absorbed dose was twice as high for the B-Mo system as for the A(Mo) and B-W systems for both conventional and digital technique. The mammograms produced with the screen-film combination gave a significantly better detectability than the storage phosphor plates used in this study. Substantial dose reduction could be achieved using anode/filter combination of W/Rh instead of Mo/Mo with no significant loss of information in the images.
引用
收藏
页码:591 / 597
页数:7
相关论文
共 50 条
  • [31] PATIENT DOSES AND RADIATION RISKS IN FILM-SCREEN MAMMOGRAPHY IN FINLAND
    SERVOMAA, A
    PARVIAINEN, T
    KOMPPA, T
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 449 - 454
  • [32] Comparative Effectiveness of Digital Versus Film-Screen Mammography RESPONSE
    Kerlikowske, Karla
    Hubbard, Rebecca
    ANNALS OF INTERNAL MEDICINE, 2012, 156 (03) : 251 - 251
  • [33] ON THE MEASUREMENT OF HALF-VALUE LAYER IN FILM-SCREEN MAMMOGRAPHY
    WAGNER, LK
    ARCHER, BR
    CERRA, F
    MEDICAL PHYSICS, 1990, 17 (06) : 989 - 997
  • [34] EFFECTIVE BREAST-CANCER DETECTION WITH FILM-SCREEN MAMMOGRAPHY
    SCHMITT, EL
    THREATT, BA
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1985, 36 (04): : 304 - 307
  • [35] Film-screen versus digitized mammography: Assessment of clinical equivalence
    Powell, KA
    Obuchowski, NA
    Chilcote, WA
    Barry, MM
    Ganobcik, SN
    Cardenosa, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) : 889 - 894
  • [36] Storage phosphor direct magnification mammography in comparison with conventional screen-film mammography - a phantom study
    Funke, M
    Breiter, N
    Hermann, KP
    Oestmann, JW
    Grabbe, E
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (845): : 528 - 534
  • [37] The positive predictive value for diagnosis of breast cancer: Full-field digital mammography versus film-screen mammography in the diagnostic mammographic population
    Seo, Bo Kyoung
    Pisano, Etta D.
    Kuzmiak, Cherie M.
    Koomen, Marcia
    Pavic, Dag
    McLelland, Robert
    Lee, Yeonhee
    Cole, Elodia B.
    Mattingly, Dianne
    Lee, Juneyoung
    ACADEMIC RADIOLOGY, 2006, 13 (10) : 1229 - 1235
  • [38] Cost and cost-effectiveness of digital mammography compared with film-screen mammography in Australia
    Wang, Shuhong
    Merlin, Tracy
    Kreisz, Florian
    Craft, Paul
    Hiller, Janet E.
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF PUBLIC HEALTH, 2009, 33 (05) : 430 - 436
  • [39] INTERSTITIAL PULMONARY-DISEASE - A COMPARISON BETWEEN FILM-SCREEN TECHNIQUE AND DIGITAL STORAGE PHOSPHOR TECHNIQUE
    DOLKEN, W
    CHOWANETZ, W
    HORWITZ, AE
    KRAHE, T
    LANDWEHR, P
    LACKNER, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (01): : 61 - 67
  • [40] Digital vs. film-screen mammography: Radiation dose and SNR
    Nickoloff, E
    Dutta, A
    Lu, Z
    Smith, S
    Rosenblatt, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1307 - 1307